This is a
Motion sensor can be included and operated in any Z-Wave network with other Z-Wave certified devices. The features list:1)Z-Wave Plus certified for wide compatibility (500 serials product).2)Supports Security 0 and Security 2 protected mode with AES-128 encryption.3)Motion sensor.4)Tamper alarm by shock sensor.5)The battery life is up to 1 year.6)Low battery alarm.7)Support firmware OTA.
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | 1. Notification Report.Sensor will send Notification Report to the associated nodes when Motion sensor iO is removed or/and PIR is triggered.2. Battery Report.Motion sensor iO will send Battery Report when the battery level is low and the battery reports value is 0xFF.3. Device Reset Locally Notification.4.Association Group 1 is the lifeline group |
2 | 5 | Motion sensor iO will send Basic Set to associated nodes when the PIR is triggered. |
The higher the value, the more sensitive the PIR sensor. Size: 1 Byte, Default Value: 8
Setting | Description |
---|---|
0 | Disabled motion detection |
1 - 8 | The higher the value, the more sensitive the PIR sensor. |
Motion sensor can send BASIC SET command to nodes associated with group 2 when motion is triggered. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
Motion Sensor can reverse its value of BASIC SET when motion is triggered. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Send BASIC SET VALUE = 255 to nodes associated with group 2 when motion alarm is triggered.Send BASIC SET VALUE = 0 to nodes associated with group 2 when motion alarm is canceled. |
1 | Send BASIC SET VALUE = 0 to nodes associated with group 2 when motion alarm is triggered.Send BASIC SET VALUE = 255 to nodes associated with group 2 when motion alarm is canceled. |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | when the value is 0, the product will not sends a vibration alarm after moving or shaking; |
1 | when the value is 1, the product will sends a vibration alarm after moving or shaking |
Motion alarm will be cancelled in the main controller after 3 seconds, the alarm cancellation can be delay by this parameter. Any motion detected during the cancellation delay time countdown will result in the countdown being restarted. Size: 2 Byte, Default Value: 30
Setting | Description |
---|---|
0 | Reports are not sent |
1 - 65535 | the change in luminance level resulting in luminance report being sent to the main controller. |
Define a battery level as the low battery. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
10 - 50 | The low level from 10% to 50% |
Hardware Platform | ZM5101 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 1 FW: 1.00 |
Z-Wave Version | 6.71.01 |
Certification ID | ZC10-20076938 |
Z-Wave Product Id | 0x0208.0x0200.0x0012 |
Sensors | |
Supported Notification Types | |
Color | Antique Brass |
Firmware Updatable | Not Updatable |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |