Quickstart

This is a secure Light Dimmer Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The micro smart dimmer is a Z-Wave device designed to work with various types of light sources. It may be connected to two-wire or three-wire configuration so it can operate with or without neutral lead. The dimmer can switch or dim connected light source either through Z-Wave devices or through the wall switch connected directly to it. The smart dimmer is equipped with an algorithm of smart light source detection which makes configuration easier and ensures high compatibility of the device. It may be usedas a switch with non-dimmable light sources (in 3-wire onnection).

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 1. When press and hold down Reset button for 10S to reset the dimmer, send u0022Device Reset Locally Notification CCu0022 to associated devices of this group to report factory reset information.2. When load state changes, send u0022Basic Report CCu0022 to associated devices of this group.3. When a load over current is detected, send u0022Over-current detectedu0022 to Lifeline.4. When a mains voltage drop is detected, send u0022Voltage drop/driftu0022 to Lifeline.5. When over temperature is detected, send Emergency shutoff statusu0022 to Lifeline.

Configuration Parameters

Parameter 11: Wiring type

Wiring typeNote: this parameter is read only
Size: 1 Byte, Default Value: 0

Setting Description
0 unknown
1 2 Wire With No Neutral
2 3 Wire With Neutral

Parameter 12: Load type

Load typeNote: this parameter is read only
Size: 1 Byte, Default Value: 0

Setting Description
0 unknown
1 resistive
2 inductive
3 capacitive

Parameter 13: Enable/disable over current protection

Enable/disable over current protection (over 1.5A for 20 seconds continuously)
Size: 1 Byte, Default Value: 1

Setting Description
0 disable
1 enable

Parameter 14: Power automatic report absolute threshold, unit is W

Power automatic report absolute threshold, unit is WWhen power changes above the absolutethreshold, immediately report current power value
Size: 2 Byte, Default Value: 10

Setting Description
0 - 32767 When power changes above the absolute threshold, immediately report current power value

Parameter 15: Power automatic report percentage threshold, unit is %

Power automatic report percentage threshold, unit is %When power changes above the percentage threshold, immediately report current power value
Size: 1 Byte, Default Value: 20

Setting Description
0 - 100 When power changes above the percentage threshold, immediately report current power value

Parameter 2: Saving load state before power failure

Saving load state before power failure
Size: 1 Byte, Default Value: 2

Setting Description
0 shutoff load
1 turn on load
2 save load state before power failure

Parameter 21: Power metering automatic report time cycle, unit is second

Power metering automatic report time cycle, unit is second
Size: 4 Byte, Default Value: 600

Setting Description
5 - 2678400 Power metering automatic report time cycle, unit is second

Parameter 22: Energy metering automatic report time cycle, unit is second

Energy metering automatic report time cycle, unit is second
Size: 4 Byte, Default Value: 1800

Setting Description
5 - 2678400 Energy metering automatic report time cycle, unit is second

Parameter 23: Voltage metering automatic report time cycle, unit is second

Voltage metering automatic report time cycle, unit is second
Size: 4 Byte, Default Value: 3600

Setting Description
5 - 2678400 Voltage metering automatic report time cycle, unit is second

Parameter 24: Current metering automatic report time cycle, unit is second

Current metering automatic report time cycle, unit is second
Size: 4 Byte, Default Value: 3600

Setting Description
5 - 2678400 Current metering automatic report time cycle, unit is second

Parameter 3: Enable/disable to send the basic report

Enable/disable to send the basic report to the Lifeline when the load state changed (When value set as 1, re-power on the dimmer, it will send Basic report automatically
Size: 1 Byte, Default Value: 1

Setting Description
0 Disable to send Basic report
1 Enable to send Basic report

Parameter 31: Setting dimming curve

Setting dimming curve
Size: 1 Byte, Default Value: 0

Setting Description
0 linear dimming
1 logarithmic dimming

Parameter 32: Setting startup brightness of the load

Setting startup brightness of the loadValid value: 0~99Note: every time when turn on the load from OFF status, if thetarget brightness is lower than the startup brightness, thebrightness will first go to the startup brightness value thenfall down to the target brightness
Size: 1 Byte, Default Value: 0

Setting Description
0 - 99 Setting startup brightness of the load

Parameter 4: Default fade time

Default fade time (unit is second)
Size: 1 Byte, Default Value: 1

Setting Description
0 Instantly
1 - 127 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution.

Parameter 5: Setting minimum brightness value

Setting minimum brightness value
Size: 1 Byte, Default Value: 0

Setting Description
0 - 50 the bigger the value is, the higher the loads minimum brightness is

Parameter 6: Setting maximum brightness value

Setting maximum brightness value
Size: 1 Byte, Default Value: 100

Setting Description
0 - 100 the maximum brightness value

Parameter 7: Choose MOSFET driving type

Choose MOSFET driving type
Size: 1 Byte, Default Value: 0

Setting Description
0 trailing edge
1 leading edge

Parameter 8: External switch type

External switch type
Size: 1 Byte, Default Value: 0

Setting Description
0 Push button switch
1 normal on/off switch
2 3-way switch

Parameter 9: Enable/disable external switch to be added to and removed from a network

Enable/disable external switch to be added to and removed from a network (when enables this function, triple press the external switch within 1.5 seconds to be added to or removed from a network)
Size: 1 Byte, Default Value: 1

Setting Description
0 disable
1 enable

Technical Data

Hardware Platform ZM5101
Device Type Light Dimmer Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.06
Z-Wave Version 6.71.03
Certification ID ZC10-20076932
Z-Wave Product Id 0x0438.0x0200.0xD00C
Supported Meter Type Electric Energy
Firmware Updatable Updatable by Consumer by RF
Supported Notification Types Power ManagementSystem
Frequency XXfrequency
Maximum transmission power XXantenna
Light Dimmer Switch