This is a
The micro smart dimmer is a Z-Wave device designed to work with various types of light sources. It may be connected to two-wire or three-wire configuration so it can operate with or without neutral lead. The dimmer can switch or dim connected light source either through Z-Wave devices or through the wall switch connected directly to it. The smart dimmer is equipped with an algorithm of smart light source detection which makes configuration easier and ensures high compatibility of the device. It may be usedas a switch with non-dimmable light sources (in 3-wire onnection).
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | 1. When press and hold down Reset button for 10S to reset the dimmer, send u0022Device Reset Locally Notification CCu0022 to associated devices of this group to report factory reset information.2. When load state changes, send u0022Basic Report CCu0022 to associated devices of this group.3. When a load over current is detected, send u0022Over-current detectedu0022 to Lifeline.4. When a mains voltage drop is detected, send u0022Voltage drop/driftu0022 to Lifeline.5. When over temperature is detected, send Emergency shutoff statusu0022 to Lifeline. |
Wiring typeNote: this parameter is read only Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | unknown |
1 | 2 Wire With No Neutral |
2 | 3 Wire With Neutral |
Load typeNote: this parameter is read only Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | unknown |
1 | resistive |
2 | inductive |
3 | capacitive |
Enable/disable over current protection (over 1.5A for 20 seconds continuously) Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | disable |
1 | enable |
Power automatic report absolute threshold, unit is WWhen power changes above the absolutethreshold, immediately report current power value Size: 2 Byte, Default Value: 10
Setting | Description |
---|---|
0 - 32767 | When power changes above the absolute threshold, immediately report current power value |
Power automatic report percentage threshold, unit is %When power changes above the percentage threshold, immediately report current power value Size: 1 Byte, Default Value: 20
Setting | Description |
---|---|
0 - 100 | When power changes above the percentage threshold, immediately report current power value |
Saving load state before power failure Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | shutoff load |
1 | turn on load |
2 | save load state before power failure |
Power metering automatic report time cycle, unit is second Size: 4 Byte, Default Value: 600
Setting | Description |
---|---|
5 - 2678400 | Power metering automatic report time cycle, unit is second |
Energy metering automatic report time cycle, unit is second Size: 4 Byte, Default Value: 1800
Setting | Description |
---|---|
5 - 2678400 | Energy metering automatic report time cycle, unit is second |
Voltage metering automatic report time cycle, unit is second Size: 4 Byte, Default Value: 3600
Setting | Description |
---|---|
5 - 2678400 | Voltage metering automatic report time cycle, unit is second |
Current metering automatic report time cycle, unit is second Size: 4 Byte, Default Value: 3600
Setting | Description |
---|---|
5 - 2678400 | Current metering automatic report time cycle, unit is second |
Enable/disable to send the basic report to the Lifeline when the load state changed (When value set as 1, re-power on the dimmer, it will send Basic report automatically Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disable to send Basic report |
1 | Enable to send Basic report |
Setting dimming curve Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | linear dimming |
1 | logarithmic dimming |
Setting startup brightness of the loadValid value: 0~99Note: every time when turn on the load from OFF status, if thetarget brightness is lower than the startup brightness, thebrightness will first go to the startup brightness value thenfall down to the target brightness Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 99 | Setting startup brightness of the load |
Default fade time (unit is second) Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Instantly |
1 - 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution. |
Setting minimum brightness value Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 50 | the bigger the value is, the higher the loads minimum brightness is |
Setting maximum brightness value Size: 1 Byte, Default Value: 100
Setting | Description |
---|---|
0 - 100 | the maximum brightness value |
Choose MOSFET driving type Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | trailing edge |
1 | leading edge |
External switch type Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Push button switch |
1 | normal on/off switch |
2 | 3-way switch |
Enable/disable external switch to be added to and removed from a network (when enables this function, triple press the external switch within 1.5 seconds to be added to or removed from a network) Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | disable |
1 | enable |
Hardware Platform | ZM5101 |
Device Type | Light Dimmer Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.06 |
Z-Wave Version | 6.71.03 |
Certification ID | ZC10-20076932 |
Z-Wave Product Id | 0x0438.0x0200.0xD00C |
Supported Meter Type | Electric Energy |
Firmware Updatable | Updatable by Consumer by RF |
Supported Notification Types | Power ManagementSystem |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |