Quickstart

This is a secure Wall Controller for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The remote control is a Z-Wave device that can both control other Z-Wave devices and activate scenes inGateways. Although it is controlling other devices, the device cannot act as Z-Wave network controller (primaryor secondary) and will always need a Z-Wave network controller to be included into a Z-Wave network. It alsosupports the Over The Air (OTA) feature for the products firmware upgrade.The remote control has following functions:1. Control of groups of other Z-Wave devices using 'ON', 'OFF' and Dim commands.2. Activation of scenes in Gateway mode.The encryption modes that the remote control supports are S0, S2 Authenticated, S2 Unauthenticated. Whenthe remote control is being included into a Z-Wave network, you can use your primary controller/gateway toenable one encryption mode or disable encryption. (The primary controller/gateway shall support encryptionmode configuration).

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 1. Send Command Class u0022Device Reset Locally Notification V1u0022 toassociated devices of this group to report factory reset informationwhen factory reset the remote control.2. When remote control battery power value changes, sendCommand Class u0022Battery Report V1u0022 to associated devices of thisgroup to report power value information.3. Short press or press and hold down any button to send sceneactivation command to the associated devices of this group usingCommand Class Central Scene Notification V3
2 5 Short press / button of Group 2 to send ON/OFF command toassociated devices of this group using Command Class u0022Basic SetV2u0022.Press and hold down / button of Group 2 to send light intensityincrease/decrease command to associated devices of this groupusing Command Class u0022Multilevel V4u0022.
3 5 Short press / button of Group 3 to send ON/OFFcommand to associated devices of this group usingCommand Class u0022Basic Set V2u0022.Press and hold down / button of Group 3 to sendlight intensity increase/decrease command toassociated devices of this group using Command Classu0022Multilevel V4u0022.

Configuration Parameters

Parameter 1: factory reset

Value=0x55AA, other values are invalid,factory reset the Remote Control
Size: 2 Byte, Default Value: 21930

Setting Description
21930 factory reset

Technical Data

Hardware Platform ZM5101
Device Type Wall Controller
Network Operation Portable Slave
Firmware Version HW: 1 FW: 1.26
Z-Wave Version 6.71.03
Certification ID ZC10-20066929
Z-Wave Product Id 0x0438.0x0300.0xa306
Firmware Updatable Updatable by Consumer by RF
Z-Wave Scene Type Central Scene
Frequency XXfrequency
Maximum transmission power XXantenna
Wall Controller