Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The Universal Module is used to translate wired products into wireless Z-WaveTM protocol, integratingthem into the Z-Wave network of a smarthome environment. It has 3 sets of input terminals and 3 sets ofrelay output. Through the Universal Module, the Z-Wave Controller can read the input signal from wiredsensors and control the output of wired actuators. This product can be operated in any Z-Wave networkwith other Z-Wave certified devices from other manufactures. All mains operated nodes within thenetwork will act as repeater regardless of vender to increase reliability of the network.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 1.When its battery level drops to unacceptable level, a Battery report will be sent to Lifeline group. 2.Whenperforming Factory Reset, a Device Reset Locally Notification will be sent to Lifeline group. 3.When relays atOUT1~3 turns on/off. (For automatic turn off, there will be a 2 secs delay after the turn off is complete), aSwitch Binary Report will be sent to Lifeline group. 4. When Voltage level at Signal Input (periodic report), aSensor Multilevel report will be sent to Lifeline group.
2 5 Mirror of endpoint 1
3 5 Mirror of endpoint 2
4 5 Mirror of endpoint 3

Configuration Parameters

Parameter 1: IN1 Mode

Tell the device to active IN1 Mode
Size: 1 Byte, Default Value: 64

Setting Description
0 - 255 Size =1, Default Value = 0x40Bit 7Corresponds to values in Config 4, 5 - 0 = Trigger on when voltage under Low-threshold, Trigger off when over Hi-threshold - 1 = Trigger on when voltage over Hi-threshold, Trigger off when under Low-thresholdBit 6IN1 3.3V pull-high On/Off , 0 = Off,1 = On Bit 5-4 : Fixed at 0. Bit 31 = Activate OUT3 relay when IN1 trigger Bit 21 = Activate OUT2 relay when IN1 trigger Bit 11 = Activate OUT1 relay when IN1 trigger Bit 0Fixed at 0.

Parameter 10: IN2 Low-threshold Voltage Trigger Level

Low threshold voltage level for trigger on (or trigger off, depending on mode)
Size: 1 Byte, Default Value: 10

Setting Description
0 - 255 Size =1 Default Value = 0x0A (IN2 trigger on when under 1000mV)

Parameter 11: IN3 Mode

Tell the device to active IN3 Mode
Size: 1 Byte, Default Value: 64

Setting Description
0 - 255 Same as for IN1Bit 7Corresponds to values in Config 14, 15

Parameter 12: OUT3 relay Trigger ON time

Relay 3 turn on period
Size: 1 Byte, Default Value: 5

Setting Description
0 - 255 Size =1, Default Value = 0x05 (500ms) Step of 100ms, 0 = remain on

Parameter 13: Group 4 turn on time when triggered by IN3

Group 4 turn on period.
Size: 1 Byte, Default Value: 180

Setting Description
0 - 255 Size =1, Default Value = 0xB4 (Off after 180 secs) Step of 1 sec, 0 = remain on

Parameter 14: IN3 Hi-threshold Voltage Trigger Level

High threshold voltage level for trigger on (or trigger off, depending on mode).
Size: 1 Byte, Default Value: 25

Setting Description
0 - 255 Size =1, Default Value = 0x19 (IN3 trigger off when over 2500mV). Step of 100mV.

Parameter 15: IN3 Low-threshold Voltage Trigger Level

Low threshold voltage level for trigger on (or trigger off, depending on mode).
Size: 1 Byte, Default Value: 10

Setting Description
0 - 255 Size =1 Default Value = 0x0A (IN3 trigger on when under 1000mV)

Parameter 16: Auto Report Voltage time

Periodic auto report for voltage input at IN1~3.
Size: 1 Byte, Default Value: 30

Setting Description
0 - 255 Size =1, Default Value = 0x1E (30mins) Step= 1 min.

Parameter 17: Tamper Mode

0: No activate relay out1: Activate OUT1 Relay when Tamper2: Activate OUT2 Relay when Tamper3: Activate OUT1 & OUT2 Relay when Tamper4: Activate OUT3 Relay when Tamper5: Activate OUT1 & OUT3 Relay when Tamper6: Activate OUT2 & OUT3 Relay when Tamper7: Activate OUT1 & OUT2 & OUT3 Relay when Tamper
Size: 1 Byte, Default Value: 0

Setting Description
0 - 7 Size =1, Default Value = 0x00Bit 31 = Activate OUT3 Relay when Tamper Bit 21 = Activate OUT2 Relay when Tamper Bit 11 = Activate OUT1 Relay when Tamper

Parameter 18: Set ARM/DISARM Input

0: No ARM/DISARM Input1: IN 1 is ARM/DISARM Input2: IN 2 is ARM/DISARM Input3: IN 3 is ARM/DISARM Input
Size: 1 Byte, Default Value: 0

Setting Description
0 - 3 0: No ARM/DISARM Input 1: IN 1 is ARM/DISARM Input 2: IN 2 is ARM/DISARM Input 3: IN 3 is ARM/DISARM Input

Parameter 2: OUT1 relay Trigger ON time

Relay 1 turn on period
Size: 1 Byte, Default Value: 5

Setting Description
0 - 255 Size =1, Default Value = 0x05 (500ms) Step of 100ms, 0 = remain on

Parameter 3: Group 2 turn on time when triggered by IN1

Group 2 turn on period
Size: 1 Byte, Default Value: 180

Setting Description
0 - 255 Size =1, Default Value = 0xB4 (Off after 180 secs)Step of 1 sec, 0 = remain on

Parameter 4: IN1 Hi-threshold Voltage Trigger Level

High threshold voltage level for trigger on (or trigger off, depending on mode).
Size: 1 Byte, Default Value: 25

Setting Description
0 - 255 Size =1, Default Value = 0x19 (IN1 trigger off when over 2500mV). Step of 100mV.

Parameter 5: IN1 Low-threshold Voltage Trigger Level

Low threshold voltage level for trigger on (or trigger off, depending on mode).
Size: 1 Byte, Default Value: 10

Setting Description
0 - 255 Size =1 Default Value = 0x0A (IN1 trigger on when under 1000mV)

Parameter 6: IN2 Mode

Tell the device to active IN2 Mode
Size: 1 Byte, Default Value: 64

Setting Description
0 - 255 Same as for IN1Bit 7Corresponds to values in Config 9, 10

Parameter 7: OUT2 relay Trigger ON time

Relay 2 turn on period
Size: 1 Byte, Default Value: 5

Setting Description
0 - 255 Size =1, Default Value = 0x05 (500ms) Step of 100ms, 0 = remain on

Parameter 8: Group 3 turn on time when triggered by IN2

Group 3 turn on period
Size: 1 Byte, Default Value: 180

Setting Description
0 - 255 Size =1, Default Value = 0xB4 (Off after 180 secs) Step of 1 sec, 0 = remain on

Parameter 9: IN2 Hi-threshold Voltage Trigger Level

High threshold voltage level for trigger on (or trigger off, depending on mode).
Size: 1 Byte, Default Value: 25

Setting Description
0 - 255 Size =1, Default Value = 0x19 (IN2 trigger off when over 2500mV). Step of 100mV.

Technical Data

Hardware Platform SD3502
Device Type Notification Sensor
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.01:00.01
Z-Wave Version 6.81.06
Certification ID ZC10-20056913
Z-Wave Product Id 0x0060.0x0016.0x0001
Color White
Firmware Updatable Updatable by Consumer by RF
Frequency XXfrequency
Maximum transmission power XXantenna
Notification Sensor