Quickstart

This is a secure On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

This valves controller PAB04 is a security enabled wireless switch, based on Z-Wave Plus technology. Z-Wave Plus TM enabled devices displaying the Z-Wave Plus TM logo can also be used with it regardless of the manufacturer, and can also be used in other manufacturers Z-Wave TM enabled networks. Remote On/Off control of the connected valve is possible with other manufacturers wireless Controller. Each switch is designed to act as a repeater. Repeaters will re-transmit the RF signal to ensure that the signal is received by its intended destination by routing the signal around obstacles and radio dead spots. Because PAB04 supports Security Command Class, it can learn with Secured controller. Its functionality and supported command classes is identical when included as a secure and non-secure device. Connect PAB04 with an external water meter which can output pulse signals. PAB04 is able to detect instance water flow and the accumulated water.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 The Switch can be set to send reports to associated Z-Wave devices. It supports one association group with 5 nodes support for Grouping 1. For group 1, Lifeline, the Switch will report its latest status to Z-Wave Controller. Grouping 1 Lifeline supports SWITCH_BINARY_REPORTMETER_REPORTSENSOR_MULTILEVEL_REPORT and RESET_LOCALLY_NOTIFICATION.

Configuration Parameters

Parameter 1: Unit of Accumulated Water Flow

If the setting is configured for accumulated cubic meters (set value =2), PAB04 will report its accumulated water flow every 1 hour to Group1 nodes. The default setting value is KL.
Size: 1 Byte, Default Value: 2

Setting Description
1 1 : US Gallon
2 2. KL

Parameter 2: Threshold of Accumulated Water Flow

When the accumulated water is over the threshold of accumulated water flow, PAB04 will send meter report of its Accumulated water flow (KL or US gallon) to Group1 nodes. For example : If the threshold of accumulated water flow is set as 1KL. PAB04 will send meter report whenever it detects the accumulated water flow crossing over 1KL2KL3KLetc.
Size: 2 Byte, Default Value: 1

Setting Description
0 0 : Disable accumulated meter report
1 - 255 1~255 : 1~255 US Gallon or KL

Parameter 3: Differential of Instant Water Flow

When the variation of instant water flow is over the differential, PAB04 will send Multilevel Sensor report (Liter/h) to group1 nodes. In order to avoid too frequent report, it will not report when the instant water flow vary lower than the configured percentage of one liter.
Size: 1 Byte, Default Value: 10

Setting Description
0 0 : Disable instant water flow Report
1 - 100 1~100 : 1% ~ 100%

Parameter 4: Pulse count per liter

The calculation of accumulated water flow and instant water flow is based on this value of the attached meter. Check the specification of the water meter, you can find Pulse Frequency.For example : 7.5Q, Q is flow rate in L/min. Then the pulse count per liter will be 450, this value is count from 7.5 (L/min) multiply 60 seconds.
Size: 2 Byte, Default Value: 450

Setting Description
1 - 32767 450 Pulse/L

Parameter 5: Relay Control mode

If the relay control mode is set as 0 (NC), it will turn on the valve by closing the relay contact. If the relay control mode is set as 1 (NO), it will turn on the valve by opening the relay contact.
Size: 1 Byte, Default Value: 0

Setting Description
0 0 : NC
1 1 : NO

Parameter 6: Periodic Auto Report Timer

The auto report timer define how long will PAB04 report the meter report of accumulated water flow. At the same time it also sand the Multilevel Sensor report of instant water flow and Switch Binary Report of the state of the connected valve.
Size: 2 Byte, Default Value: 60

Setting Description
0 0Disable Periodic Auto Report
1 - 1440 1~1440 1min ~ 1440 min

Technical Data

Hardware Platform SD3502
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.01
Z-Wave Version 6.81.03
Certification ID ZC10-20026864
Z-Wave Product Id 0x013C.0x0001.0x0076
Color White
Firmware Updatable Updatable by Consumer by RF
Frequency XXfrequency
Maximum transmission power XXantenna
On/Off Power Switch