This product can be included and operated in any Z-Wave TM network with other Z-Wave TMcertified devices from other manufacturers and/or other applications.All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 4 | Used for returned events. |
2 | 4 | Used for Basic set event. |
Setting the BASIC command value.When the flood trigger off(0x00), send the BASIC CC to the group 2. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-127 - 127 | Setting the BASIC command value. |
The interval time for auto report the battery level. Size: 1 Byte, Default Value: 12
Setting | Description |
---|---|
0 - 127 | The tick time can setting by the configuration No.20. |
The interval time for auto report the temperature. Size: 1 Byte, Default Value: 12
Setting | Description |
---|---|
0 - 127 | The tick time can setting by the configuration No.20. |
The interval time for auto report the humidity. Size: 1 Byte, Default Value: 12
Setting | Description |
---|---|
0 - 127 | The tick time can setting by the configuration No.20. |
The interval time for auto report the flood state. Size: 1 Byte, Default Value: 12
Setting | Description |
---|---|
0 - 127 | The tick time can setting by the configuration No.20. |
Setting the BASIC command value.When the flood trigger on(0xFF), send the BASIC CC to the group 2. Size: 1 Byte, Default Value: -1
Setting | Description |
---|---|
-127 - 127 | Setting the BASIC command value. |
The interval time for auto report each tick. Size: 1 Byte, Default Value: 30
Setting | Description |
---|---|
-127 - 127 | Units of one minute. |
The temperature differential to report. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 127 | The unit is Fahrenheit. |
The humidity differential to report. Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 - 60 | The unit is percentage. |
Operation mode. Using bit to control. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Disable the Flood function. |
8 | Setting the temperature scale. |
32 | Disable the temperature report after event triggered. |
Multisensor function switch. Using bit to control. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
64 | Disable the humidity report after event triggered. |
Customer function switch, using bit control. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
8 | Disable send out BASIC OFF after the flood event cleared. |
64 | Disable to report battery state when the device triggered. |
Hardware Platform | SD3502 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 1 FW: 1.01:01.14 |
Z-Wave Version | 6.81.03 |
Certification ID | ZC10-20026862 |
Z-Wave Product Id | 0x013C.0x0002.0x0078 |
Firmware Updatable | Not Updatable |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |