Quickstart

This is a secure On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

PRODUCT FEATURES:- Powerful dry contact relays to control loads up to 15 A and 20 A- Perfect for outdoor lighting, pool pumps, garage door, or gas fireplace- Control up to 3 connected loads independently or together- Z-Wave or optional wall switch control (toggle or momentary type)- Built-in timers for each relay to simplify automation- Remembers and restores on/off status after power failure- Powered by 12-24 V DC/AC or USB C port for easy set-up- Wall mounting and minimal design for clean installation- S2 security protocol and the latest 500 Z-Wave chipSPECIFICATIONS:- Model Number: ZEN16- Z-Wave Signal Frequency: 908.42 MHz- Power: 12-24 V DC/AC or USB C-Maximum Load: Relay 1: 15A (1/3 HP), Relay 2: 15A (1/3 HP),Relay 3: 20A (3/4 HP)

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Basic set reports sent to the hub from the device.
2 5 Basic set reports sent to associated devices when Relay 1 changes state.
3 5 Basic set reports sent to associated devices when Relay 2 changes state.
4 5 Basic set reports sent to associated devices when Relay 3 changes state.

Configuration Parameters

Parameter 1: On Off Status After Power Failure

Set the on off status for the relays after power failure.
Size: 1 Byte, Default Value: 1

Setting Description
0 ALL relays forced to OFF (regardless of state prior to power outage);
1 ALL relays remember and restore on/off status after power failure
2 ALL relays forced to ON (regardless of state prior to power outage);
3 Relay 1 and Relay 2 remember and restore on/off status after power failure, Relay 3 forced to OFF;
4 Relay 1 and Relay 2 remember and restore on/off status after power failure, Relay 3 forced to ON.

Parameter 10: Auto Turn-Off Timer for Relay 3

Use this parameter to set thetime aer which you want the deviceconnected to Relay 3 to automatically turn offonce it has been turned on. The numberentered as value corresponds to the numberof minutes.
Size: 4 Byte, Default Value: 0

Setting Description
0 timer disabled
1 - 65535 minutes

Parameter 11: Auto Turn-On Timer for Relay 3

Use this parameter to set thetime aer which you want the deviceconnected to Relay 3 to automatically turn ononce it has been turned off. The numberentered as value corresponds to the numberof minutes.
Size: 4 Byte, Default Value: 0

Setting Description
0 timer disabled
1 - 65535 minutes

Parameter 12: Enable/Disable Manual Control for Sw1

Enable or disable physicalon/off control of Relay 1 from the wall switchconnected to Sw1 terminal. If disabled, youllonly be able to control the connected devicevia Z-Wave.
Size: 1 Byte, Default Value: 1

Setting Description
0 local control disabled
1 local control enabled

Parameter 13: Enable/Disable Manual Control for Sw2

Enable or disable physicalon/off control of Relay 2 from the wall switchconnected to Sw2 terminal. If disabled, youllonly be able to control the connected devicevia Z-Wave.
Size: 1 Byte, Default Value: 1

Setting Description
0 local control disabled
1 local control enabled

Parameter 14: Enable/Disable Manual Control for Sw3

Enable or disable physicalon/off control of Relay 3 from the wall switchconnected to Sw3 terminal. If disabled, youllonly be able to control the connected devicevia Z-Wave.
Size: 1 Byte, Default Value: 1

Setting Description
0 local control disabled
1 local control enabled

Parameter 2: Switch Type for Relay 1 (Sw1)

Choose the wall switch type youwant to connect to the Sw1 terminal.
Size: 1 Byte, Default Value: 2

Setting Description
0 momentary switch
1 toggle switch (light on when the switch is toggled up, light off when the switch is toggled down);
2 toggle switch (state changes whenever the switch is toggled).

Parameter 3: Switch Type for Relay 2 (Sw2)

Choose the wall switch type you want to connect to the Sw2 terminal.
Size: 1 Byte, Default Value: 2

Setting Description
0 momentary switch
1 toggle switch (light on when the switch is toggled up, light off when the switch is toggled down);
2 toggle switch (state changes whenever the switch is toggled)

Parameter 4: Switch Type for Relay 3 (Sw3)

Choose the wall switch type you want to connect to the Sw3 terminal.
Size: 1 Byte, Default Value: 2

Setting Description
0 momentary switch
1 toggle switch (light on when the switch is toggled up, light off when the switch is toggled down)
2 toggle switch (state changes whenever the switch is toggled)

Parameter 5: LED Indicator Control

Choose if you want the LEDindicator to turn on when any of the relays areon or if all of them are off, or if you want it toremain on or off at all times.
Size: 1 Byte, Default Value: 0

Setting Description
0 LED indicator is on when ALL of the relays are off, LED indicator is off when any of the relays is on (default);
1 LED indicator is on when any of the relays is on, LED indicator is off when ALL of the relays are off
2 LED indicator is always OFF
3 LED indicator is always ON.

Parameter 6: Auto Turn-Off Timer for Relay 1

Use this parameter to set thetime aer which you want the deviceconnected to Relay 1 to automatically turn offonce it has been turned on. The numberentered as value corresponds to the numberof minutes.
Size: 4 Byte, Default Value: 0

Setting Description
0 timer disabled
1 - 65535 minutes

Parameter 7: Auto Turn-On Timer for Relay 1

Use this parameter to set thetime aer which you want the device connected to Relay 1 to automatically turn ononce it has been turned off. The numberentered as value corresponds to the numberof minutes.
Size: 4 Byte, Default Value: 0

Setting Description
0 timer disabled
1 - 65535 minutes

Parameter 8: Auto Turn-Off Timer for Relay 2

Use this parameter to set thetime aer which you want the deviceconnected to Relay 2 to automatically turn offonce it has been turned on. The numberentered as value corresponds to the numberof minutes.
Size: 4 Byte, Default Value: 0

Setting Description
0 timer disabled
1 - 65535 minutes

Parameter 9: Auto Turn-On Timer for Relay 2

Use this parameter to set thetime aer which you want the deviceconnected to Relay 2 to automatically turn ononce it has been turned off. The numberentered as value corresponds to the numberof minutes.
Size: 4 Byte, Default Value: 0

Setting Description
0 timer disabled
1 - 65535 minutes

Technical Data

Hardware Platform ZM5202
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.00
Z-Wave Version 6.82.00
Certification ID ZC10-20016854
Z-Wave Product Id 0x027A.0xa000.0xa00a
Loads Controlled 3
Color Black
Firmware Updatable Updatable by Consumer by RF
Electric Load Type IncandescentInductive (e.g. Motor)LED
Frequency XXfrequency
Maximum transmission power XXantenna
On/Off Power Switch