This is a
PRODUCT FEATURES:- Powerful dry contact relays to control loads up to 15 A and 20 A- Perfect for outdoor lighting, pool pumps, garage door, or gas fireplace- Control up to 3 connected loads independently or together- Z-Wave or optional wall switch control (toggle or momentary type)- Built-in timers for each relay to simplify automation- Remembers and restores on/off status after power failure- Powered by 12-24 V DC/AC or USB C port for easy set-up- Wall mounting and minimal design for clean installation- S2 security protocol and the latest 500 Z-Wave chipSPECIFICATIONS:- Model Number: ZEN16- Z-Wave Signal Frequency: 908.42 MHz- Power: 12-24 V DC/AC or USB C-Maximum Load: Relay 1: 15A (1/3 HP), Relay 2: 15A (1/3 HP),Relay 3: 20A (3/4 HP)
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Basic set reports sent to the hub from the device. |
2 | 5 | Basic set reports sent to associated devices when Relay 1 changes state. |
3 | 5 | Basic set reports sent to associated devices when Relay 2 changes state. |
4 | 5 | Basic set reports sent to associated devices when Relay 3 changes state. |
Set the on off status for the relays after power failure. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | ALL relays forced to OFF (regardless of state prior to power outage); |
1 | ALL relays remember and restore on/off status after power failure |
2 | ALL relays forced to ON (regardless of state prior to power outage); |
3 | Relay 1 and Relay 2 remember and restore on/off status after power failure, Relay 3 forced to OFF; |
4 | Relay 1 and Relay 2 remember and restore on/off status after power failure, Relay 3 forced to ON. |
Use this parameter to set thetime aer which you want the deviceconnected to Relay 3 to automatically turn offonce it has been turned on. The numberentered as value corresponds to the numberof minutes. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | timer disabled |
1 - 65535 | minutes |
Use this parameter to set thetime aer which you want the deviceconnected to Relay 3 to automatically turn ononce it has been turned off. The numberentered as value corresponds to the numberof minutes. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | timer disabled |
1 - 65535 | minutes |
Enable or disable physicalon/off control of Relay 1 from the wall switchconnected to Sw1 terminal. If disabled, youllonly be able to control the connected devicevia Z-Wave. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | local control disabled |
1 | local control enabled |
Enable or disable physicalon/off control of Relay 2 from the wall switchconnected to Sw2 terminal. If disabled, youllonly be able to control the connected devicevia Z-Wave. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | local control disabled |
1 | local control enabled |
Enable or disable physicalon/off control of Relay 3 from the wall switchconnected to Sw3 terminal. If disabled, youllonly be able to control the connected devicevia Z-Wave. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | local control disabled |
1 | local control enabled |
Choose the wall switch type youwant to connect to the Sw1 terminal. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | momentary switch |
1 | toggle switch (light on when the switch is toggled up, light off when the switch is toggled down); |
2 | toggle switch (state changes whenever the switch is toggled). |
Choose the wall switch type you want to connect to the Sw2 terminal. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | momentary switch |
1 | toggle switch (light on when the switch is toggled up, light off when the switch is toggled down); |
2 | toggle switch (state changes whenever the switch is toggled) |
Choose the wall switch type you want to connect to the Sw3 terminal. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | momentary switch |
1 | toggle switch (light on when the switch is toggled up, light off when the switch is toggled down) |
2 | toggle switch (state changes whenever the switch is toggled) |
Choose if you want the LEDindicator to turn on when any of the relays areon or if all of them are off, or if you want it toremain on or off at all times. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | LED indicator is on when ALL of the relays are off, LED indicator is off when any of the relays is on (default); |
1 | LED indicator is on when any of the relays is on, LED indicator is off when ALL of the relays are off |
2 | LED indicator is always OFF |
3 | LED indicator is always ON. |
Use this parameter to set thetime aer which you want the deviceconnected to Relay 1 to automatically turn offonce it has been turned on. The numberentered as value corresponds to the numberof minutes. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | timer disabled |
1 - 65535 | minutes |
Use this parameter to set thetime aer which you want the device connected to Relay 1 to automatically turn ononce it has been turned off. The numberentered as value corresponds to the numberof minutes. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | timer disabled |
1 - 65535 | minutes |
Use this parameter to set thetime aer which you want the deviceconnected to Relay 2 to automatically turn offonce it has been turned on. The numberentered as value corresponds to the numberof minutes. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | timer disabled |
1 - 65535 | minutes |
Use this parameter to set thetime aer which you want the deviceconnected to Relay 2 to automatically turn ononce it has been turned off. The numberentered as value corresponds to the numberof minutes. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | timer disabled |
1 - 65535 | minutes |
Hardware Platform | ZM5202 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.00 |
Z-Wave Version | 6.82.00 |
Certification ID | ZC10-20016854 |
Z-Wave Product Id | 0x027A.0xa000.0xa00a |
Loads Controlled | 3 |
Color | Black |
Firmware Updatable | Updatable by Consumer by RF |
Electric Load Type | IncandescentInductive (e.g. Motor)LED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |