This is a
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
PRODUCT FEATURES:- Powerful dry contact relays to control loads up to 15 A and 20 A- Perfect for outdoor lighting, pool pumps, garage door, or gas fireplace- Control up to 3 connected loads independently or together- Z-Wave or optional wall switch control (toggle or momentary type)- Built-in timers for each relay to simplify automation- Remembers and restores on/off status after power failure- Powered by 12-24 V DC/AC or USB C port for easy set-up- Wall mounting and minimal design for clean installation- S2 security protocol and the latest 500 Z-Wave chipSPECIFICATIONS:- Model Number: ZEN16- Z-Wave Signal Frequency: 908.42 MHz- Power: 12-24 V DC/AC or USB C-Maximum Load: Relay 1: 15A (1/3 HP), Relay 2: 15A (1/3 HP),Relay 3: 20A (3/4 HP)
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Basic set reports sent to the hub from the device. |
2 | 5 | Basic set reports sent to associated devices when Relay 1 changes state. |
3 | 5 | Basic set reports sent to associated devices when Relay 2 changes state. |
4 | 5 | Basic set reports sent to associated devices when Relay 3 changes state. |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Set the on off status for the relays after power failure. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | ALL relays forced to OFF (regardless of state prior to power outage); |
1 | ALL relays remember and restore on/off status after power failure |
2 | ALL relays forced to ON (regardless of state prior to power outage); |
3 | Relay 1 and Relay 2 remember and restore on/off status after power failure, Relay 3 forced to OFF; |
4 | Relay 1 and Relay 2 remember and restore on/off status after power failure, Relay 3 forced to ON. |
Use this parameter to set thetime aer which you want the deviceconnected to Relay 3 to automatically turn offonce it has been turned on. The numberentered as value corresponds to the numberof minutes. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | timer disabled |
1 - 65535 | minutes |
Use this parameter to set thetime aer which you want the deviceconnected to Relay 3 to automatically turn ononce it has been turned off. The numberentered as value corresponds to the numberof minutes. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | timer disabled |
1 - 65535 | minutes |
Enable or disable physicalon/off control of Relay 1 from the wall switchconnected to Sw1 terminal. If disabled, youllonly be able to control the connected devicevia Z-Wave. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | local control disabled |
1 | local control enabled |
Enable or disable physicalon/off control of Relay 2 from the wall switchconnected to Sw2 terminal. If disabled, youllonly be able to control the connected devicevia Z-Wave. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | local control disabled |
1 | local control enabled |
Enable or disable physicalon/off control of Relay 3 from the wall switchconnected to Sw3 terminal. If disabled, youllonly be able to control the connected devicevia Z-Wave. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | local control disabled |
1 | local control enabled |
Choose the wall switch type youwant to connect to the Sw1 terminal. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | momentary switch |
1 | toggle switch (light on when the switch is toggled up, light off when the switch is toggled down); |
2 | toggle switch (state changes whenever the switch is toggled). |
Choose the wall switch type you want to connect to the Sw2 terminal. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | momentary switch |
1 | toggle switch (light on when the switch is toggled up, light off when the switch is toggled down); |
2 | toggle switch (state changes whenever the switch is toggled) |
Choose the wall switch type you want to connect to the Sw3 terminal. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | momentary switch |
1 | toggle switch (light on when the switch is toggled up, light off when the switch is toggled down) |
2 | toggle switch (state changes whenever the switch is toggled) |
Choose if you want the LEDindicator to turn on when any of the relays areon or if all of them are off, or if you want it toremain on or off at all times. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | LED indicator is on when ALL of the relays are off, LED indicator is off when any of the relays is on (default); |
1 | LED indicator is on when any of the relays is on, LED indicator is off when ALL of the relays are off |
2 | LED indicator is always OFF |
3 | LED indicator is always ON. |
Use this parameter to set thetime aer which you want the deviceconnected to Relay 1 to automatically turn offonce it has been turned on. The numberentered as value corresponds to the numberof minutes. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | timer disabled |
1 - 65535 | minutes |
Use this parameter to set thetime aer which you want the device connected to Relay 1 to automatically turn ononce it has been turned off. The numberentered as value corresponds to the numberof minutes. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | timer disabled |
1 - 65535 | minutes |
Use this parameter to set thetime aer which you want the deviceconnected to Relay 2 to automatically turn offonce it has been turned on. The numberentered as value corresponds to the numberof minutes. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | timer disabled |
1 - 65535 | minutes |
Use this parameter to set thetime aer which you want the deviceconnected to Relay 2 to automatically turn ononce it has been turned off. The numberentered as value corresponds to the numberof minutes. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | timer disabled |
1 - 65535 | minutes |
Hardware Platform | ZM5202 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.00 |
Z-Wave Version | 6.82.00 |
Certification ID | ZC10-20016854 |
Z-Wave Product Id | 0x027A.0xa000.0xa00a |
Loads Controlled | 3 |
Color | Black |
Firmware Updatable | Updatable by Consumer by RF |
Electric Load Type | IncandescentInductive (e.g. Motor)LED |
Security V2 | S2_UNAUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |