Quickstart

This is a Wall Controller for XXXQFrequencyName. To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

Master Dimmer iO is ready to operate with Z-Wave controllers and configured to be managed by Simon100 iO APP using the HUB plug iO for getting a better user experience. allowing the control of other Z-Wave devices via Basic Set/Get commands.Available colors Black and White.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 3 Z-Wave Plus LifelineAfter reset the Z-Wave module, a DEVICE-RESET-LOCALLY-NOTIFICATION is sent.Pressing without having nodes associated with the control group is notified by a CENTRAL_SCENE_NOTIFICATION
2 20 CtrlDuring Association process or then Association Set is receivedCC Manufacturer Specific, Manufacturer Specific Get: (to discover manufacturer)CC Association, Association Set: (review param 28 to know more about this command use).CC Association, Association Remove: (review param 28 to know more about this command use).CC Configuration, Configuration Set Param 1, 0xFF -> when association process is started this Configuration Set will be sent to all Simon devices in group to identify devices involved in this group.CC Configuration, Configuration Set Param 1, 0x00 -> when association process is finished this Configuration Set will be sent to all Simon devices in group to identify devices involved in this group.CC Configuration, Configuration Set Param 1, 0xFF ->Sent when a new device is associated thought association process and this device is a Simon device.CC Configuration, Configuration Set Param 1, 0x00 -> Sent when a device is disassociated thought association process and this device is a Simon device.When Touch area is detected o key is pressed without touch area detection:CC Configuration, Configuration Get, Param 21 -> Sent if param 28 value is 0x00, there is only 1 device is associated and it is a Simon device. Used to know the associated device state.CC Basic, Basic Get -> Sent if param 28 value is 0x00, there is only 1 device is associated and it is not a Simon device. Used to know the associated device state.When pressed and later than knowing the controlled devices state:COMMAND_CLASS_BASIC_SETIt is sent to the associated nodes after a push to change its state:Value: 0xFF to enable / 0x00 to disableIt is relayed to the associated nodes when Z-Wave receives a BASIC_SET.COMMAND_CLASS_MULTILEVEL_SETIt is sent to the associated nodes after a push to change its state:It is relayed to the associated nodes upon receipt by Z-Wave.

Configuration Parameters

Parameter 1: Association LED

Allows to turn ON or OFF the central LED
Size: 1 Byte, Default Value: 0

Setting Description
0 Turns the LED OFF
255 Turns the LED ON

Parameter 12: Behavior of LED in repose

Sets the central led ilumination when the key is in repose state
Size: 1 Byte, Default Value: 0

Setting Description
0 LED OFF
255 LED on at 20 percent of maximum level

Parameter 13: Lock Input

Locks or Unlocks the direct control of the load
Size: 1 Byte, Default Value: 0

Setting Description
0 Unlock the direct control of load
255 Lock the direct control of load

Parameter 15: Reset default

Resets groups, Z-Wave status, and some or all configurations depending on the configuration value (write only)
Size: 2 Byte, Default Value: 0

Setting Description
17170 Parameters, except Lock long press are restored to default
39015 Parameters, Groups, and Z-Wave status are restored to default value.

Parameter 18: Manual association lock

Locks or unlocks the manual association
Size: 1 Byte, Default Value: 0

Setting Description
0 Unblocked
255 Blocked

Parameter 19: Press action

Controls the behavior of the product when the key is pressed
Size: 1 Byte, Default Value: 0

Setting Description
0 When short press, switches between the last power on and off (depending on the status of the associated control) by sending a Basic Set to 0x00 or 0xFF to the associated nodes. The Slider does not work.
1 When short press, always activates those associated with the last power on by sending a Basic Set to 0xFF
2 When short press, always deactivates associates by sending a Basic Set to 0x00
4 When short press, always activates the associated nodes by sending a Basic Set to 0xFFWhen hold press from 2 seconds to 10 seconds always turns off the associated nodes by sending a Basic Set to 0x00. Does not send Node Info nor does the central LED flash.
5 The described actions are performed for value 0, but sending the Multilevel Set

Parameter 20: Identify

Allows to identify a product using its central LED (write only)
Size: 1 Byte, Default Value: 0

Setting Description
255 the central LED blinks for 5 seconds in order to identify the device

Parameter 21: Device state

Reports the actual state of the device
Size: 2 Byte, Default Value: 0

Setting Description
45056 Load is OFF
45057 Load is ON
45312 Lighting percentage level associated node

Parameter 27: Lock long press

Locks or unlocks the long press on the key
Size: 1 Byte, Default Value: 0

Setting Description
0 Long press works as described previously
255 Long press from 2 seconds to 20 seconds does not send a Node info. With a long press above 30 seconds, all parameters except Lock long press are restored to default and device sends a Node Info.

Parameter 28: Consult on Touch Detection

Controls if a state of an associated device or devices will be consulted when touch is detected
Size: 1 Byte, Default Value: 0

Setting Description
0 If there is 1 Associated device, when Touch is detected, controlled device state will be consulted
255 If there is 1 Associated device, when Touch is detected, controlled device state is not consulted.

Parameter 29: Enable automatic reporting CENTRAL_SCENE

Enables or disables the Central Scene Command Class
Size: 1 Byte, Default Value: 0

Setting Description
0 Enables CC Central Scene Notification when there are no nodes associated with the control group and Inhibits error signaling by pressing less than 2 seconds if there are no associated nodes.
255 Enables error signaling by pressing less than 2 seconds if there are no associated nodes

Technical Data

Hardware Platform ZM5202
Device Type Wall Controller
Network Operation Always On Slave
Firmware Version HW: 1 FW: 4.24:79.50
Z-Wave Version 6.51.07
Certification ID ZC10-20016849
Z-Wave Product Id 0x0267.0x0008.0x0000
Firmware Updatable Updatable by Professional/Technician
Neutral Wire Required ok
Z-Wave Scene Type Central Scene
Frequency XXfrequency
Maximum transmission power XXantenna
Wall Controller