Simon iO Dimmer is integrated by Electronic Dimmer and a Rocker,that provides Z-Wave communication attributes. The touch surface offers a slider area in order to adjust the light level showing the dimming intensity with 7 LEDs . Simon iO Dimmer is ready to operate with Z-Wave controllers and configured to be managed by Simon100 IO APP using the HUB plug IO for getting a better user experience.
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 3 | On/Off Report when load state is changed:- On -> CC Basic, Basic Report, Value 0x01 - 0x63 Report the dimming level- Off -> CC Basic, Basic Report, Value 0x00Instant Power Consumption vary over 10% and is stable almost 2sec- CC Meter, Meter Report, Electric meter, Consumed, Watts, Size 4, Precision 1, Value (W)Calibration requirement change. (If device needs to be calibrated and is Added into a Z-Wave network,it will report after receive an Association Set of life line).- Calibration required -> CC Configuration, Configuration Report, Param 23, Value 0xFF- Calibration not required -> CC Configuration, Configuration Report, Param 23, Value 0x00After reset the Z-Wave module, a DEVICE-RESET-LOCALLY-NOTIFICATION is sent. |
2 | 20 | On/Off Report when load state is changed: |
Allows to turn ON or OFF the central LED Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Turns the LED OFF |
-128 | Turns the central LED ON |
Sets the delay time to turn on the light Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Instantly. Disable timming |
1 - 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution |
-128 - -1 | 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution |
Sets the time the light stays on Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Instantly. Disable timming |
1 - 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution |
-128 - -1 | 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution |
Sets the central led illumination when the key is in repose state Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | LED OFF |
-128 | Central LED on at 20% of maximum level |
Locks or Unlocks the direct control of the load Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Unlock the direct control of load. |
-128 | Lock the direct control of the load |
Resets groups, Z-Wave status, and some or all configurations depending on the configuration value (write-only) Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
-26521 | Parameters, Groups, and Z-Wave status are restored to default. |
17170 | Parameters, except Lock long press are restored to default |
Sets the delay time to turn off the light Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Instantly. Disable timming |
1 - 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution |
-128 - -1 | 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution |
Controls the behavior of the product when the key is pressed Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 | when press t is less than 2sec device toggles the load. The Slider does not work |
1 | when press t is less than 2secc device turns ON the load. The Slider does not works |
2 | when press t is less than 2sec device turns OFF the load. The Slider does not works |
4 | when press t is less than 2sec device turns ON the load. when press time is between 2 and 10 seconds device turns OFF the load. The Slider does not works.With this configuration, the device will not send the Node Info neither Show the LEDs feedback with this press action. The Slider does not works. |
5 | (default value) when press t is less than 2sec device toggles the load. The Slider dims the load when it is ON. |
Allows to identify a product using its central LED (write only) Size: 1 Byte, Default Value: -128
Setting | Description |
---|---|
-128 | Allows to identify a product using its central LED |
Reports the state of the charge (read only) Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
-20480 | Load is OFF |
-20479 | Load is ON |
-20224 - -20125 | Last active dimming value |
Reports if calibration is required or not (read only) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Calibration is not required |
-128 | It is necessary to calibrate the dimmer to work properly |
Locks or unlocks the long press on the key Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-128 | Hold Press from 2sec to 20 sec does not performs a Node info,Hold Press of 10 to 15 does not performs a automatic callibration,Hold press of 15 to 30 does not changes the sunblind or awing changes, Hold press of 30sec restores configuration except Lock Hold Press, and sends a Node info in order to add or remove from Z-Wave Network |
0 | Long press works as described previously |
Sets the time it takes to turn on the light (ramp time) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Instantly. Disable timming |
1 - 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution |
-128 - -1 | 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution |
Sets the time it takes to turn off the light (ramp time) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Instantly. Disable timming |
1 - 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution |
-128 - -1 | 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution |
Sets the minimum dimming value in percentage Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 - 99 | Sets the minimum dimming value in percentage |
Sets the maximum dimming value in percentage Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 - 99 | Sets the maximum dimming value in percentage |
Returns or sets the last non zero dimming value. In case of Set, the device turns ON the load Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 - 99 | Returns or sets the last non zero dimming value. |
Performs a device calibration Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | Device performs calibration using Trailing and leading Edge and decides which one is better. |
2 | Device is calibrated using Trailing Edge |
3 | Device is calibrated using Leading Edge |
Hardware Platform | ZM5202 |
Device Type | Light Dimmer Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 4.24:78.59:70.48 |
Z-Wave Version | 6.51.07 |
Certification ID | ZC10-20016848 |
Z-Wave Product Id | 0x0267.0x0007.0x0000 |
Firmware Updatable | Updatable by Professional/Technician |
Electric Load Type | Dimmable ELV (Magnetic)Dimmable LEDDimmable MLV (Magnetic)Incandescent |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |