This is a
Roller Blind IO is ready to operate with Z-Wave controllers and configured to be managed by Simon100 IO APP using the HUB plug IO for getting a better user experience. Sending the Blind Up/Down or setting a specific position
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 3 | Z-Wave Plus LifelinePosition Report when Sunblind is stopped and is changed:- % new position -> CC Basic, Basic Report, Value 0xXX from 0x00 to 0x63Calibration requirement change. (If device needs to be calibrated and is Added into a Z-Wave network, it will report after receive an Association Set of life line).- Calibration required -> CC Configuration, Configuration Report, Param 23, Value 0xFF- Calibration not required -> CC Configuration, Configuration Report, Param 23, Value 0x00After reset the Z-Wave module, a DEVICE-RESET-LOCALLY-NOTIFICATION is sent. |
2 | 20 | CtrlWhen Touch area is detected o key is pressed without touch area detection:CC Configuration, Configuration Get, Param 21 -> Sent if param 28 value is 0x00, there is only 1 device is associated and it is a Simon device. Used to know the associated device state.CC Basic, Basic Get -> Sent if param 28 value is 0x00, there is only 1 device is associated and it is not a Simon device. Used to know the associated device state.COMMAND_CLASS_BASIC_REPORTAssociates are sent when the sunblind remains stoped for 1.5s after changing positions.% New position -> CC Basic, Basic Report, Value 0x00 - 0x63 |
Allows to turn ON or OFF the central LED Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Turns the LED OFF |
255 - 0 | Turns the LED ON |
Sets the central led ilumination when the key is in repose state Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | LED OFF |
255 | LED on at 20 percent of maximum level |
Locks or Unlocks the direct control of the load Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Unlock the direct control of load. |
255 | Lock the direct control of load |
Performs a device calibration Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
255 | Sunblind starts its callibration process |
Resets groups, Z-Wave status, and some or all configurations depending on the configuration value (write only) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
17170 | Parameters, except Lock long press are restored to default |
39015 | Parameters, Groups, and Z-Wave status are restored to default |
Allows to identify a product using its central LED (write only) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
255 | The central LED blinks for 5 seconds in order to identify the device |
Reports the actual state of the load Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
45056 | LED OFF |
45057 | LED ON |
45312 | LED OFF |
45567 | LED ON |
Reports if calibration is required or not (read only) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Calibration is not required |
255 | It is necessary to calibrate the curtain to work properly |
Changes operating mode between Windows shutter and Sunblind Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 | Operating mode for Window Shutter |
255 | Operating Mode for SundBlinds |
Locks or unlocks the long press on the key Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Long press works as described previously |
255 | Long press from 2 seconds to 20 seconds does not send a Node info. With a long press above 30 seconds, all parameters except Lock long press are restored to default and device sends a Node Info. |
Sets time it takes to pull up the blind (ramp time) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Instantly |
1 - 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution |
128 - 255 | 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution |
Sets time it takes to pull down the blind (ramp time) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Instantly |
1 - 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution |
128 - 254 | 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution |
Hardware Platform | ZM5202 |
Device Type | Window Covering - Pos/End Aware |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 4.24:75.53:66.47 |
Z-Wave Version | 6.51.07 |
Certification ID | ZC10-20016844 |
Z-Wave Product Id | 0x0267.0x0004.0x0000 |
Firmware Updatable | Updatable by Professional/Technician |
Window Covering Control Features | Automatic Calibration |
Neutral Wire Required | ok |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |