Quickstart

This is a Window Covering - Pos/End Aware for XXXQFrequencyName. To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

Roller Blind IO is ready to operate with Z-Wave controllers and configured to be managed by Simon100 IO APP using the HUB plug IO for getting a better user experience. Sending the Blind Up/Down or setting a specific position

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 3 Z-Wave Plus LifelinePosition Report when Sunblind is stopped and is changed:- % new position -> CC Basic, Basic Report, Value 0xXX from 0x00 to 0x63Calibration requirement change. (If device needs to be calibrated and is Added into a Z-Wave network, it will report after receive an Association Set of life line).- Calibration required -> CC Configuration, Configuration Report, Param 23, Value 0xFF- Calibration not required -> CC Configuration, Configuration Report, Param 23, Value 0x00After reset the Z-Wave module, a DEVICE-RESET-LOCALLY-NOTIFICATION is sent.
2 20 CtrlWhen Touch area is detected o key is pressed without touch area detection:CC Configuration, Configuration Get, Param 21 -> Sent if param 28 value is 0x00, there is only 1 device is associated and it is a Simon device. Used to know the associated device state.CC Basic, Basic Get -> Sent if param 28 value is 0x00, there is only 1 device is associated and it is not a Simon device. Used to know the associated device state.COMMAND_CLASS_BASIC_REPORTAssociates are sent when the sunblind remains stoped for 1.5s after changing positions.% New position -> CC Basic, Basic Report, Value 0x00 - 0x63

Configuration Parameters

Parameter 1: Association LED

Allows to turn ON or OFF the central LED
Size: 1 Byte, Default Value: 0

Setting Description
0 Turns the LED OFF
255 - 0 Turns the LED ON

Parameter 12: Behavior of LED in repose

Sets the central led ilumination when the key is in repose state
Size: 1 Byte, Default Value: 0

Setting Description
0 LED OFF
255 LED on at 20 percent of maximum level

Parameter 13: Lock Input

Locks or Unlocks the direct control of the load
Size: 1 Byte, Default Value: 0

Setting Description
0 Unlock the direct control of load.
255 Lock the direct control of load

Parameter 14: Calibration

Performs a device calibration
Size: 1 Byte, Default Value: 0

Setting Description
255 Sunblind starts its callibration process

Parameter 15: Reset Default

Resets groups, Z-Wave status, and some or all configurations depending on the configuration value (write only)
Size: 1 Byte, Default Value: 0

Setting Description
17170 Parameters, except Lock long press are restored to default
39015 Parameters, Groups, and Z-Wave status are restored to default

Parameter 20: Identify

Allows to identify a product using its central LED (write only)
Size: 1 Byte, Default Value: 0

Setting Description
255 The central LED blinks for 5 seconds in order to identify the device

Parameter 21: Device state

Reports the actual state of the load
Size: 1 Byte, Default Value: 0

Setting Description
45056 LED OFF
45057 LED ON
45312 LED OFF
45567 LED ON

Parameter 23: Calibration required

Reports if calibration is required or not (read only)
Size: 1 Byte, Default Value: 0

Setting Description
0 Calibration is not required
255 It is necessary to calibrate the curtain to work properly

Parameter 24: Operating Mode

Changes operating mode between Windows shutter and Sunblind
Size: 1 Byte, Default Value: 255

Setting Description
0 Operating mode for Window Shutter
255 Operating Mode for SundBlinds

Parameter 27: Lock long press

Locks or unlocks the long press on the key
Size: 1 Byte, Default Value: 0

Setting Description
0 Long press works as described previously
255 Long press from 2 seconds to 20 seconds does not send a Node info. With a long press above 30 seconds, all parameters except Lock long press are restored to default and device sends a Node Info.

Parameter 4: UP Time

Sets time it takes to pull up the blind (ramp time)
Size: 1 Byte, Default Value: 0

Setting Description
0 Instantly
1 - 127 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution
128 - 255 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution

Parameter 5: DOWN Time

Sets time it takes to pull down the blind (ramp time)
Size: 1 Byte, Default Value: 0

Setting Description
0 Instantly
1 - 127 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution
128 - 254 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution

Technical Data

Hardware Platform ZM5202
Device Type Window Covering - Pos/End Aware
Network Operation Always On Slave
Firmware Version HW: 1 FW: 4.24:75.53:66.47
Z-Wave Version 6.51.07
Certification ID ZC10-20016844
Z-Wave Product Id 0x0267.0x0004.0x0000
Firmware Updatable Updatable by Professional/Technician
Window Covering Control Features Automatic Calibration
Neutral Wire Required ok
Frequency XXfrequency
Maximum transmission power XXantenna
Window Covering - Pos/End Aware