This is a
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Roller Blind IO is ready to operate with Z-Wave controllers and configured to be managed by Simon100 IO APP using the HUB plug IO for getting a better user experience. Sending the Blind Up/Down or setting a specific position
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 3 | Z-Wave Plus LifelinePosition Report when Sunblind is stopped and is changed:- % new position -> CC Basic, Basic Report, Value 0xXX from 0x00 to 0x63Calibration requirement change. (If device needs to be calibrated and is Added into a Z-Wave network, it will report after receive an Association Set of life line).- Calibration required -> CC Configuration, Configuration Report, Param 23, Value 0xFF- Calibration not required -> CC Configuration, Configuration Report, Param 23, Value 0x00After reset the Z-Wave module, a DEVICE-RESET-LOCALLY-NOTIFICATION is sent. |
2 | 20 | CtrlWhen Touch area is detected o key is pressed without touch area detection:CC Configuration, Configuration Get, Param 21 -> Sent if param 28 value is 0x00, there is only 1 device is associated and it is a Simon device. Used to know the associated device state.CC Basic, Basic Get -> Sent if param 28 value is 0x00, there is only 1 device is associated and it is not a Simon device. Used to know the associated device state.COMMAND_CLASS_BASIC_REPORTAssociates are sent when the sunblind remains stoped for 1.5s after changing positions.% New position -> CC Basic, Basic Report, Value 0x00 - 0x63 |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Allows to turn ON or OFF the central LED Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Turns the LED OFF |
255 - 0 | Turns the LED ON |
Sets the central led ilumination when the key is in repose state Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | LED OFF |
255 | LED on at 20 percent of maximum level |
Locks or Unlocks the direct control of the load Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Unlock the direct control of load. |
255 | Lock the direct control of load |
Performs a device calibration Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
255 | Sunblind starts its callibration process |
Resets groups, Z-Wave status, and some or all configurations depending on the configuration value (write only) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
17170 | Parameters, except Lock long press are restored to default |
39015 | Parameters, Groups, and Z-Wave status are restored to default |
Allows to identify a product using its central LED (write only) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
255 | The central LED blinks for 5 seconds in order to identify the device |
Reports the actual state of the load Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
45056 | LED OFF |
45057 | LED ON |
45312 | LED OFF |
45567 | LED ON |
Reports if calibration is required or not (read only) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Calibration is not required |
255 | It is necessary to calibrate the curtain to work properly |
Changes operating mode between Windows shutter and Sunblind Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 | Operating mode for Window Shutter |
255 | Operating Mode for SundBlinds |
Locks or unlocks the long press on the key Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Long press works as described previously |
255 | Long press from 2 seconds to 20 seconds does not send a Node info. With a long press above 30 seconds, all parameters except Lock long press are restored to default and device sends a Node Info. |
Sets time it takes to pull up the blind (ramp time) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Instantly |
1 - 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution |
128 - 255 | 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution |
Sets time it takes to pull down the blind (ramp time) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Instantly |
1 - 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution |
128 - 254 | 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution |
Hardware Platform | ZM5202 |
Device Type | Window Covering - Pos/End Aware |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 4.24:75.53:66.47 |
Z-Wave Version | 6.51.07 |
Certification ID | ZC10-20016843 |
Z-Wave Product Id | 0x0267.0x0004.0x0000 |
Neutral Wire Required | ok |
Window Covering Control Features | |
Firmware Updatable | |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |