This is a
Socket iO is ready to operate with Z-Wave controllers and configured to be managed by Simon100 iO APP using the HUB plug iO for getting a better user experience. allowing the control of the socket and LEDs integrated.
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 3 | Z-Wave Plus LifelineCOMMAND_CLASS_BASIC_REPORTIt is sent to the associated nodes when the loadchanges state:ON-> 0xFFOFF-> 0x00COMMAND_CLASS_METER_REPORT_V4It is sent to the associated nodes when the powerconsumed varies more than 10%Electric meter, Consumed, Watts, Size 4, Precision 1, Value (W)COMMAND_CLASS_DEVICE_RESET_LOCALLY_NOTIFICATIONThe associated nodes are sent when the device isremoved from the Z-Wave network |
2 | 20 | CtrlCOMMAND_CLASS_BASIC_REPORTIt is sent to the associated nodes when the loadchanges state:ON-> 0xFFOFF-> 0x00 |
Allows to turn ON or OFF the central LED Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Turns the LED OFF |
255 | Turns the LED ON |
Sets the delay time to turn on the device Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disables timing |
1 - 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution |
128 - 254 | 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution |
Sets the time the device stays on Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disables timing |
1 - 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution |
128 - 254 | 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution |
Locks or Unlocks the direct control of the load Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Enables the push button to control the load |
255 | Disables the action of the push button of the load |
Resets groups, Z-Wave status, and some or all configurations depending on the configuration value (write only) Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
17170 | Parameters, except Lock long press are restored to default |
39015 | Parameters, Groups, and Z-Wave status are restored to default |
Sets the delay time to turn off the device Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disables timing |
1 - 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution |
128 - 254 | 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution |
Controls the state of the load after a reset action Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 | Restart with the relay disabled. |
255 | Recover the previous state. |
Controls the behavior of the product when the key is pressed Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | When short press, device toggles the load |
1 | When short press, device turns ON the load |
2 | When short press, device turns OFF the load |
Allows to set a power consumption limit in Watts Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disables custom consumption limit |
1 - 65535 | Sets the power in Watts that is supported |
Allows to identify a product using its central LED (write only) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
255 | the central LED blinks for 5 seconds in order to identify the device |
Reports the state of the charge (read only) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
45056 | Load is OFF |
45057 | Load is ON |
45312 | Load is OFF |
45567 | Load is ON |
Locks or unlocks the long press on the key Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Long press works as described previously |
255 | Long press from 2 seconds to 30 seconds does not send a Node info. With a long press above 30 seconds, all parameters except Lock long press are restored to default and device sends a Node info |
Enables or disables the beacon function Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disables the beacon function |
1 - 99 | Sets the intensity of the beacon LEDs |
Hardware Platform | ZM5202 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 4.24:68.49 |
Z-Wave Version | 6.51.07 |
Certification ID | ZC10-20016836 |
Z-Wave Product Id | 0x0267.0x0009.0x0000 |
Neutral Wire Required | ok |
Supported Meter Type | Electric Energy |
Firmware Updatable | Updatable by Professional/Technician |
Switch Type | Push Button with Indicator |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |