Quickstart

This is a On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

Simon Electronic Switch IO integrated by Electronic Switch that provides power Switch and Rocker that provides Z-Wave communication attributes.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 3 On/Off Report when load state is changed:- On -> CC Basic, Basic Report, Value 0xFF- Off -> CC Basic, Basic Report, Value 0x00Instant Power Consumption vary over 10% and is stable almost 2sec- CC Meter, Meter Report, Electric meter, Consumed, Watts, Size 4, Precision 1, Value (W)Calibration requirement change. (If device needs to be calibrated and is Added into a Z-Wave network, it will report after receive an Association Set of life line).- Calibration required -> CC Configuration, Configuration Report, Param 23, Value 0xFF- Calibration not required -> CC Configuration, Configuration Report, Param 23, Value 0x00After reset the Z-Wave module, a DEVICE-RESET-LOCALLY-NOTIFICATION is sent.Report
2 20 Ctrl On/Off Report when load state is changed:- On -> CC Basic, Basic Report, Value 0xFF- Off -> CC Basic, Basic Report, Value 0x00

Configuration Parameters

Parameter 1: Association LED

Allows to turn ON or OFF the central LED
Size: 1 Byte, Default Value: 0

Setting Description
0 Turns the LED OFF
255 Turns the LED ON

Parameter 10: Delay ON

Sets the delay time to turn on the light
Size: 1 Byte, Default Value: 0

Setting Description
0 Disables timing
1 - 127 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution
128 - 254 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution

Parameter 11: Activation TIME

Sets the time the light stays on
Size: 1 Byte, Default Value: 0

Setting Description
0 Disables timing
1 - 127 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution
128 - 254 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution

Parameter 12: Behaviour of LED in repose

Sets the central led ilumination when the key is in repose state
Size: 1 Byte, Default Value: 0

Setting Description
0 LED OFF
255 LED on at 20 percent of maximum level

Parameter 13: Lock Input

Locks or Unlocks the direct control of the load
Size: 1 Byte, Default Value: 0

Setting Description
0 Unlock the direct control of load
255 Lock the direct control of load

Parameter 15: Reset default

Resets groups, Z-Wave status, and some or all configurations depending on the configuration value (write only)
Size: 2 Byte, Default Value: 0

Setting Description
17170 Parameters, except Lock long press are restored to default
39015 Parameters, Groups, and Z-Wave status are restored to default value.

Parameter 16: Delay OFF

Sets the delay time to turn off the light
Size: 1 Byte, Default Value: 0

Setting Description
0 Disables timing
1 - 127 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution
128 - 254 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution

Parameter 19: Press action

Controls the behavior of the product when the key is pressed
Size: 1 Byte, Default Value: 0

Setting Description
0 When short press, device toggles the load
1 When short press, device turns ON the load
2 When short press, device turns OFF the load
4 When short press, device turns ON the load. When hold press from 2 seconds to 10 seconds device turns OFF the load. The Slider does not works.With this configuration, the device will not send the Node Info neither Show the LEDs feedback with this press action

Parameter 20: Identify

Allows to identify a product using its central LED (write only)
Size: 1 Byte, Default Value: 0

Setting Description
255 the central LED blinks for 5 seconds in order to identify the device

Parameter 21: State of charge

Reports the state of the charge (read only)
Size: 1 Byte, Default Value: 0

Setting Description
45056 Load is OFF
45057 Load is ON
45312 Load is OFF
45567 Load is ON

Parameter 23: Calibration Required

Reports if calibration is required or not (read only)
Size: 1 Byte, Default Value: 0

Setting Description
0 Calibration is not required
255 It is necessary to calibrate the dimmer to work properly

Parameter 27: Lock long press

Locks or unlocks the long press on the key
Size: 1 Byte, Default Value: 0

Setting Description
0 Long press works as described previously
255 Long press from 2 seconds to 20 seconds does not send a Node info. With a long press above 30 seconds, all parameters except Lock long press

Parameter 9: Calibration

Performs a device calibration
Size: 1 Byte, Default Value: 0

Setting Description
1 Device performs calibration using Trailing and leading Edge and decides which one is better
2 Device is calibrated using Trailing Edge.
3 Device is calibrated using Leading Edge

Technical Data

Hardware Platform ZM5202
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 4.24:72.15:65.15
Z-Wave Version 6.51.07
Certification ID ZC10-20016833
Z-Wave Product Id 0x0267.0x0001.0x0000
Firmware Updatable Updatable by Professional/Technician
Neutral Wire Required ok
Supported Meter Type Electric Energy
Switch Type Push Button with Indicator
Frequency XXfrequency
Maximum transmission power XXantenna
On/Off Power Switch