This is a
Simon Electronic Switch IO integrated by Electronic Switch that provides power Switch and Rocker that provides Z-Wave communication attributes.
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 3 | On/Off Report when load state is changed:- On -> CC Basic, Basic Report, Value 0xFF- Off -> CC Basic, Basic Report, Value 0x00Instant Power Consumption vary over 10% and is stable almost 2sec- CC Meter, Meter Report, Electric meter, Consumed, Watts, Size 4, Precision 1, Value (W)Calibration requirement change. (If device needs to be calibrated and is Added into a Z-Wave network, it will report after receive an Association Set of life line).- Calibration required -> CC Configuration, Configuration Report, Param 23, Value 0xFF- Calibration not required -> CC Configuration, Configuration Report, Param 23, Value 0x00After reset the Z-Wave module, a DEVICE-RESET-LOCALLY-NOTIFICATION is sent.Report |
2 | 20 | Ctrl On/Off Report when load state is changed:- On -> CC Basic, Basic Report, Value 0xFF- Off -> CC Basic, Basic Report, Value 0x00 |
Allows to turn ON or OFF the central LED Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Turns the LED OFF |
255 | Turns the LED ON |
Sets the delay time to turn on the light Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disables timing |
1 - 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution |
128 - 254 | 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution |
Sets the time the light stays on Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disables timing |
1 - 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution |
128 - 254 | 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution |
Sets the central led ilumination when the key is in repose state Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | LED OFF |
255 | LED on at 20 percent of maximum level |
Locks or Unlocks the direct control of the load Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Unlock the direct control of load |
255 | Lock the direct control of load |
Resets groups, Z-Wave status, and some or all configurations depending on the configuration value (write only) Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
17170 | Parameters, except Lock long press are restored to default |
39015 | Parameters, Groups, and Z-Wave status are restored to default value. |
Sets the delay time to turn off the light Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disables timing |
1 - 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution |
128 - 254 | 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution |
Controls the behavior of the product when the key is pressed Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | When short press, device toggles the load |
1 | When short press, device turns ON the load |
2 | When short press, device turns OFF the load |
4 | When short press, device turns ON the load. When hold press from 2 seconds to 10 seconds device turns OFF the load. The Slider does not works.With this configuration, the device will not send the Node Info neither Show the LEDs feedback with this press action |
Allows to identify a product using its central LED (write only) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
255 | the central LED blinks for 5 seconds in order to identify the device |
Reports the state of the charge (read only) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
45056 | Load is OFF |
45057 | Load is ON |
45312 | Load is OFF |
45567 | Load is ON |
Reports if calibration is required or not (read only) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Calibration is not required |
255 | It is necessary to calibrate the dimmer to work properly |
Locks or unlocks the long press on the key Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Long press works as described previously |
255 | Long press from 2 seconds to 20 seconds does not send a Node info. With a long press above 30 seconds, all parameters except Lock long press |
Performs a device calibration Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Device performs calibration using Trailing and leading Edge and decides which one is better |
2 | Device is calibrated using Trailing Edge. |
3 | Device is calibrated using Leading Edge |
Hardware Platform | ZM5202 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 4.24:72.15:65.15 |
Z-Wave Version | 6.51.07 |
Certification ID | ZC10-20016833 |
Z-Wave Product Id | 0x0267.0x0001.0x0000 |
Firmware Updatable | Updatable by Professional/Technician |
Neutral Wire Required | ok |
Supported Meter Type | Electric Energy |
Switch Type | Push Button with Indicator |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |