Quickstart

This is a secure Window Covering - Pos/End Aware for XXXQFrequencyName. To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

DOOYA Z-wave curtain motor is designed with exceeding commercial standards, with its exceptional quietness and user friendly set up. Multiple control options enable the users to operate the curtain by remote, APP, or with hands. Pull to move function would be especially helpful and convenient to users who are not yet familiar with motorization. Durability in use guarantee a 10,000 times use. Additionally, the motor is more than what were mentioned above.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 GROUP 1 is lifeline service that assigned to curtain motor position. It enables the curtain motor to send reports to Z-Wave Controller or Z-Wave Gateway whenever the motor is starting or stopped.
2 5 GROUP 2 allows for Send Multilevel Report to associated devices in this group.This Group Support:

Configuration Parameters

Parameter 1: CONFIGURATION_SET

This parameter can be used to set the motor rotation direction,the motor direction isforward (Configuration Value set to 0) or the opposite direction(Configuration Value set to 1),The defaultvalue is 0
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 0: Forward 1: Opposite direction

Parameter 10: Parameter 10

Delete the limit:This command can delete the limit that has been set for the motor.
Size: 1 Byte, Default Value: 127

Setting Description
127 0x7F: Delete the device limits

Parameter 2: Set to start holding hands

This parameter can be used to set the motor open hand start function(Configuration Value set to 0) or closed(Configuration Value set to 1),The default value is 0
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 0: Enable motor open hand start function 1: Disable motor open hand start function

Parameter 3: Parameter 3

Configure weak electric switch mode:This parameter can be used to set the need of weak electric switch mode.Provide 4 kinds of weak electric switch mode is optional,respectively:Double-button reboundable switch(Configuration Value set to 1),Double-button notreboundable switch(Configuration Value set to 2),DC246 switch(Configuration Value set to 3),Single-button cyclic switch mode(Configuration Value set to 4),The default value is 1.
Size: 1 Byte, Default Value: 1

Setting Description
1 - 4 weak electric switch mode selection

Parameter 4: Parameter 4

Configure strong electric switch mode:This parameter can be used to set the need of strong electric switch mode.Provide 3 kinds of weak electric switch mode is optional,respectively:Double-button not reboundable(Configuration Value set to 0) ,Hotel mode(Configuration Value set to 1),Double-button reboundable mode(Configuration Value set to 2),The default value is 0.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 2 Configure strong electric switch mode

Parameter 5: Parameter 5

Read whether the total limit is set:This parameter can be used to read the motor's total limit is already set.Not set thelimit(Read into the Configuration Value is 0);Already set the limit(Read into the Configuration Value is 1)
Size: 1 Byte, Default Value: 0

Setting Description
0 Read whether the total limit is set

Parameter 6: Parameter 6

Read the device type:This parameter can be used to read the type of the motor.Motor types are divided into curtainmotor(Read into the Configuration Value is 0x01),shutter(Read into the Configuration Value is 0x11),Venetian blinds (Read into the Configuration Value is 0x12)
Size: 1 Byte, Default Value: 0

Setting Description
0 Read the device type:This parameter can be used to read the type of the motor
0 Read the device type:This parameter can be used to read the type of the motor

Parameter 7: Parameter 7

Read the motor power supply type:This parameter can be used to read the motor power supply typeThe power ofmotor is classified into:Mains power supply(Read into the Configuration Value is 0),battery power(Read into the Configuration Value is 1).
Size: 1 Byte, Default Value: 0

Setting Description
0 Read the motor power supply type

Parameter 8: Parameter 8

Manually set / cancel open borders:Manually set the open boundary of the curtain(Configuration Value set to 1),cancel manually open the border of the curtain(Configuration Value set to 0).
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 Manually set / cancel open borders

Parameter 9: Parameter 9

Manually set / cancel close borders:Manually set the close boundary of the curtain(Configuration Value set to 1),cancel manually close the border of the curtain(Configuration Value set to 0).
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 anually set / cancel close borders

Technical Data

Hardware Platform ZM5202
Device Type Window Covering - Pos/End Aware
Network Operation Always On Slave
Firmware Version HW: 144 FW: 1.14:01.04
Z-Wave Version 6.71.01
Certification ID ZC10-20016829
Z-Wave Product Id 0x030A.0x0103.0x0190
Frequency XXfrequency
Maximum transmission power XXantenna
Window Covering - Pos/End Aware