DOOYA Z-wave curtain motor is designed with exceeding commercial standards, with its exceptional quietness and user friendly set up. Multiple control options enable the users to operate the curtain by remote, APP, or with hands. Pull to move function would be especially helpful and convenient to users who are not yet familiar with motorization. Durability in use guarantee a 10,000 times use. Additionally, the motor is more than what were mentioned above.
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | GROUP 1 is lifeline service that assigned to curtain motor position. It enables the curtain motor to send reports to Z-Wave Controller or Z-Wave Gateway whenever the motor is starting or stopped. |
2 | 5 | GROUP 2 allows for Send Multilevel Report to associated devices in this group.This Group Support: |
This parameter can be used to set the motor rotation direction,the motor direction isforward (Configuration Value set to 0) or the opposite direction(Configuration Value set to 1),The defaultvalue is 0 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | 0: Forward 1: Opposite direction |
Delete the limit:This command can delete the limit that has been set for the motor. Size: 1 Byte, Default Value: 127
Setting | Description |
---|---|
127 | 0x7F: Delete the device limits |
This parameter can be used to set the motor open hand start function(Configuration Value set to 0) or closed(Configuration Value set to 1),The default value is 0 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | 0: Enable motor open hand start function 1: Disable motor open hand start function |
Configure weak electric switch mode:This parameter can be used to set the need of weak electric switch mode.Provide 4 kinds of weak electric switch mode is optional,respectively:Double-button reboundable switch(Configuration Value set to 1),Double-button notreboundable switch(Configuration Value set to 2),DC246 switch(Configuration Value set to 3),Single-button cyclic switch mode(Configuration Value set to 4),The default value is 1. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 - 4 | weak electric switch mode selection |
Configure strong electric switch mode:This parameter can be used to set the need of strong electric switch mode.Provide 3 kinds of weak electric switch mode is optional,respectively:Double-button not reboundable(Configuration Value set to 0) ,Hotel mode(Configuration Value set to 1),Double-button reboundable mode(Configuration Value set to 2),The default value is 0. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 2 | Configure strong electric switch mode |
Read whether the total limit is set:This parameter can be used to read the motor's total limit is already set.Not set thelimit(Read into the Configuration Value is 0);Already set the limit(Read into the Configuration Value is 1) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Read whether the total limit is set |
Read the device type:This parameter can be used to read the type of the motor.Motor types are divided into curtainmotor(Read into the Configuration Value is 0x01),shutter(Read into the Configuration Value is 0x11),Venetian blinds (Read into the Configuration Value is 0x12) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Read the device type:This parameter can be used to read the type of the motor |
0 | Read the device type:This parameter can be used to read the type of the motor |
Read the motor power supply type:This parameter can be used to read the motor power supply typeThe power ofmotor is classified into:Mains power supply(Read into the Configuration Value is 0),battery power(Read into the Configuration Value is 1). Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Read the motor power supply type |
Manually set / cancel open borders:Manually set the open boundary of the curtain(Configuration Value set to 1),cancel manually open the border of the curtain(Configuration Value set to 0). Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Manually set / cancel open borders |
Manually set / cancel close borders:Manually set the close boundary of the curtain(Configuration Value set to 1),cancel manually close the border of the curtain(Configuration Value set to 0). Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | anually set / cancel close borders |
Hardware Platform | ZM5202 |
Device Type | Window Covering - Pos/End Aware |
Network Operation | Always On Slave |
Firmware Version | HW: 144 FW: 1.14:01.04 |
Z-Wave Version | 6.71.01 |
Certification ID | ZC10-20016829 |
Z-Wave Product Id | 0x030A.0x0103.0x0190 |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |