Quickstart

This is a secure Window Covering - Pos/End Aware for XXXQFrequencyName. To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

Aeotec New Generation Nano Shutter1. Used to control the motor of Curtain, support Shutter Mode and Venetian Mode .2. Can be calibrated according to diff e rent curtains3. Used to control other Z-Wave device directly.4. Support S2, more safe and more re liable5. Support SmartStart, faster inclusion

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Used for some commands auto sending when status changed.
2 5 Retransmit when receiving the follow commands

Configuration Parameters

Parameter 120: Switch Type of External Switch 1

Used to set Switch type of External Switch 1,and reports will return automatically during identify.
Size: 1 Byte, Default Value: 0

Setting Description
0 Unidentified mode when no identify is set, and indicate identify fails when in identify.
1 2-state switch mode
2 3 way switch mode
3 Push Button mode
4 Enter automatic identification mode(The blue led will fast blink)

Parameter 121: Switch Type of External Switch 1

Used to set Switch type of External Switch 1,and reports will return automatically during identify.
Size: 1 Byte, Default Value: 0

Setting Description
0 Unidentified mode when no identify is set, and indicate identify fails when in identify.
1 2-state switch mode
2 3 way switch mode
3 Push Button mode
4 Enter automatic identification mode(The blue led will fast blink)

Parameter 20: Motor Behavior After Power ON

Setting the Motor Behavior After Power ON.
Size: 1 Byte, Default Value: 0

Setting Description
0 Stay the same position before power off last time
1 Moves to 99%
2 Moves to 0%

Parameter 22: Determine motor run direction

Note:1.Motor will stop when receiving this command in moving;2.This configuration will not change after network exclusion or ConfigurationReset.
Size: 1 Byte, Default Value: 0

Setting Description
0 Shutter mode / Venetian mode :Out 1= Up moving/ Multilevel switch = 99%, Out 2= Down moving/ Multilevel switch = 0%
1 Shutter mode : Out 1= Down moving/ Multilevel switch = 0%, Out 2= Up moving/ Multilevel switch = 99%. Venetian mode :Out 1= Up moving/ Multilevel switch = 99%, Out 2= Down moving/ Multilevel switch = 0%
2 Shutter mode : Out 1= Up moving/ Multilevel switch = 99%, Out 2= Down moving/ Multilevel switch = 0% Venetian mode: Out 1= Down moving/ Multilevel switch = 0%, Out 2= Up moving/ Multilevel switch = 99%.
3 Shutter mode / Venetian mode : Out 1= Down moving/ Multilevel switch = 0%, Out 2= Up moving/ Multilevel switch = 99%.

Parameter 248: Function Setting of External Switch S1&S2

Used to Enable/Disable function of External Switch S1&S2.Note :This value can be combine, e.g. set to 3(1+2=3),means networking function and Reset function are both enable.
Size: 1 Byte, Default Value: 1

Setting Description
1 Enable network function, inclusion/exclusion
2 Enable reset to factory default function

Parameter 255: Reset Function

Used to reset configuration parameter value to default value or reset to factory default settings.NoteParameter 0x16, 0x22, 0x23, 0x24, 0x25, 0x27, 0x28 will not reset to default value by this command.
Size: 4 Byte, Default Value: 0

Setting Description
0 Reset all configuration parameters to default settings
1431655765 reset to factory default settings and removed from the z-wave network

Parameter 34: Set the Blade Turn Time

This parameter is to config the blade turn time(unit = 0.01s),which works only for venetian mode.Details can be found in section 4.2 of Advanced information Product Manual.Note:For Venetian, if this value is set too large for blade turning, curtain may move upwards or downwards.Calibration need to work correctly.Or this setting will force the curtain to move up or down.This configuration will not change after network exclusion or Configuration Reset.
Size: 2 Byte, Default Value: 150

Setting Description
10 - 32767 0.1 - 327.67seconds

Parameter 35: Curtain Trip Time

Curtain Trip Time is about the run time of the curtain (unit = 0.01s). Details can be found in section 4.2 of Advanced information Product Manual.Note:For Venetian, if this value is set too large for blade turning, curtain may move upwards or downwards.Calibration need to work correctly.Or this setting will force the curtain to move up or down.This configuration will not change after network exclusion or Configuration Reset.
Size: 2 Byte, Default Value: 15000

Setting Description
500 - 32767 5 - 327.67 seconds

Parameter 36: Enter/Exit Calibration

Note:Product will enter the right Curtain Mode after calibration, see Configuration 0x27(39)
Size: 1 Byte, Default Value: 0

Setting Description
0 Set:Exit Calibration Report: Not in Calibration
1 Set:Enter Shutter Mode Calibration Report: In Shutter Mode Calibration
2 Set:Enter Venetian Mode Calibration Report: In Venetian Mode Calibration

Parameter 37: User confirmation for Calibration

User confirmation for Calibration(set only)
Size: 1 Byte, Default Value: 0

Setting Description
0 Go to next step of calibration

Parameter 38: Calibration Status Report

Return Calibration Status(Get or Report)
Size: 1 Byte, Default Value: 0

Setting Description
0 Calibration Complete
1 Calibration start, going to Reference Point A
2 Reach Reference Point A, going to Reference Point B
3 Reach Reference Point B, waiting for Blade turn Calibraion(Only for Venetian Mode)
4 Going to Reference Point C(Only for Venetian Mode)
5 Calibration terminated

Parameter 39: Cutain Mode Setting

Set the Curtain Mode.Note:1. This Operation will enter repositioning automatically;2. This configuration will not change after network exclusion or Configuration Reset.
Size: 1 Byte, Default Value: 0

Setting Description
0 Shutter Mode
1 Venetian Mode

Parameter 40: Repositioning

Set to begin repositioning.
Size: 1 Byte, Default Value: 1

Setting Description
1 Repositioning begins

Parameter 41: Repositioning Status Report

Used to Get repositioning Status.
Size: 1 Byte, Default Value: 0

Setting Description
0 Repositioning complete
1 in repositioning

Parameter 42: Calibration Lock

Used to enable/disable calibration lock from different ways.
Size: 1 Byte, Default Value: 1

Setting Description
0 Disable calibration
1 Enable Action Button/ Command Calibration
2 Enable Action Button/ Command/S1/S2 Calibration

Parameter 80: Switch Status Report Selection

Choose which report to send when switch status change
Size: 1 Byte, Default Value: 2

Setting Description
0 No Report
1 Basic Report
2 Switch Multilevel Report

Parameter 85: Extern Button Mode Setting

Extern Button Mode SettingNote: when setting value to 2, we advice not to set only one external switchto push button, do remember to change the controller channel beforeoperating push button, or the curtain level will be wrong.
Size: 1 Byte, Default Value: 0

Setting Description
0 S1/S2 map to Z-Wave Button
1 S1 = Open or Stop, S2 = Close or Stop Note:Operation will not change the curtain mode, including press and hold ,short press.
2 1 When configuration 0x78/79 = 03 Press and hold S1 :blade folds to 180 Press and hold S2 Blade folds to 0 Short press S1 Blinds go downwards Short press S2 Blinds go upwards Note: The device will change its curtain mode if it does not match the current mode. 2 When Configuration 0x78/79 = others S1 = Open or Stop,S2 = Close or Stop ,operation will not change the curtain mode.

Technical Data

Hardware Platform ZM5101
Device Type Window Covering - Pos/End Aware
Network Operation Always On Slave
Firmware Version HW: 141 FW: 3.01:01.03
Z-Wave Version 6.81.03
Certification ID ZC10-19126810
Z-Wave Product Id 0x0371.0x0003.0x008D
Color White
Neutral Wire Required ok
Window Covering Control Features Manual CalibrationSupports Horizontal Blinds/LouversSupports Up/Down Motion
Firmware Updatable Updatable by Consumer by RF
Frequency XXfrequency
Maximum transmission power XXantenna
Window Covering - Pos/End Aware