Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

SDCO-1-ZW is capable of sending wireless signals to the Z-Wave gateway/control panel upon detection of smoke particles or Carbon Monoxide. The device is also serially connected with other sensors in the Z-Wave gateway to serve as an extra siren. When any other sensor in the Z-Wave network is activated and sends an alarm signal, the Smoke Detector will also raise alarm with its built-in buzzer as a siren to help sound warning (for serial connection models).

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Battery CC (COMMAND_CLASS_BATTERY) Notification CC,V8 (COMMAND_CLASS_NOTIFICATION) Sensor Multilevel CC, V11 (COMMAND_CLASS_SENSOR_MULTILEVEL) Device Reset Locally CC (COMMAND_CLASS_DEVICE_RESET_LOCALLY)
2 1 When the Smoke Detector is active, it will send Basic Set (0xFF) in Group 2. When the Smoke Detector is restored, it will send Basic Set (0x00) in Group 2.

Technical Data

Hardware Platform ZM5202
Device Type Notification Sensor
Network Operation Listening Sleeping Slave
Firmware Version HW: 255 FW: 3.08
Z-Wave Version 6.81.03
Certification ID ZC10-19126806
Z-Wave Product Id 0x018E.0x0003.0x0014
Frequency XXfrequency
Maximum transmission power XXantenna
Notification Sensor