Quickstart

This is a secure On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The dual relay in-wall module contains two sets of relays and switches, with each set dedicated for controlling lighting or an appliance in your home. Each relay can be turned on/off individually using Z-wave commands or using the switches connected to the module. At 230V voltage, this module can support up to 2*4.3A output, 2*1000W resistive load. This unit is to be installed and sealed inside an electrical switch box.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 When the device is powered for the first time, the device sends a notification report to the node of group 1.When a factory reset is performed, the device sends a Reset Locally Notification to the node of group 1.When a relay output is activated by the switch, the device sends a binary switch report to the node of group 1.
2 5 When key 1 is pressed, the device sends a BASIC SET command containing a value to the nodes of group 2.(If the relay output is off, the Basic Set is value=0x00, if the relay output is on, the Basic Set is value=0xFF)
3 5 When key 2 is pressed, the device sends a BASIC SET command containing a value to the nodes of group 3.(If the relay output is off, the Basic Set is value=0x00, if the relay output is on, the Basic Set is value=0xFF)

Configuration Parameters

Parameter 1: Key 1

0: Momentary button1: Switch (Toggle)
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 0: Momentary button, 1: Switch (Toggle)

Parameter 2: Key 2

0: Momentary button1: Switch (Toggle)
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 0: Momentary button, 1: Switch (Toggle)

Parameter 3: Relay 1 Auto Off Time

0: No Auto Off
Size: 4 Byte, Default Value: 0

Setting Description
0 - 43200 0: No Auto Off

Parameter 4: Relay 2 Auto Off Time

0: No Auto Off
Size: 4 Byte, Default Value: 0

Setting Description
0 - 43200 0: No Auto Off

Parameter 5: Remember relay 1 last state

0: do not remember1: remember
Size: 1 Byte, Default Value: 1

Setting Description
0 - 1 0: do not remember, 1: remember

Parameter 6: Remember relay 2 last state

0: do not remember1: remember
Size: 1 Byte, Default Value: 1

Setting Description
0 - 1 0: do not remember, 1: remember

Technical Data

Hardware Platform SD3502
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.01:00.01
Z-Wave Version 6.81.03
Certification ID ZC10-19116788
Z-Wave Product Id 0x0403.0x0003.0x0005
Loads Controlled 2
Neutral Wire Required ok
Color White
Firmware Updatable Updatable by Consumer by RF
Frequency XXfrequency
Maximum transmission power XXantenna
On/Off Power Switch