This is a
The dual relay in-wall module contains two sets of relays and switches, with each set dedicated for controlling lighting or an appliance in your home. Each relay can be turned on/off individually using Z-wave commands or using the switches connected to the module. At 230V voltage, this module can support up to 2*4.3A output, 2*1000W resistive load. This unit is to be installed and sealed inside an electrical switch box.
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | When the device is powered for the first time, the device sends a notification report to the node of group 1.When a factory reset is performed, the device sends a Reset Locally Notification to the node of group 1.When a relay output is activated by the switch, the device sends a binary switch report to the node of group 1. |
2 | 5 | When key 1 is pressed, the device sends a BASIC SET command containing a value to the nodes of group 2.(If the relay output is off, the Basic Set is value=0x00, if the relay output is on, the Basic Set is value=0xFF) |
3 | 5 | When key 2 is pressed, the device sends a BASIC SET command containing a value to the nodes of group 3.(If the relay output is off, the Basic Set is value=0x00, if the relay output is on, the Basic Set is value=0xFF) |
0: Momentary button1: Switch (Toggle) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | 0: Momentary button, 1: Switch (Toggle) |
0: Momentary button1: Switch (Toggle) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | 0: Momentary button, 1: Switch (Toggle) |
0: No Auto Off Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 43200 | 0: No Auto Off |
0: No Auto Off Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 43200 | 0: No Auto Off |
0: do not remember1: remember Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 1 | 0: do not remember, 1: remember |
0: do not remember1: remember Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 1 | 0: do not remember, 1: remember |
Hardware Platform | SD3502 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.01:00.01 |
Z-Wave Version | 6.81.03 |
Certification ID | ZC10-19116788 |
Z-Wave Product Id | 0x0403.0x0003.0x0005 |
Loads Controlled | 2 |
Neutral Wire Required | ok |
Color | White |
Firmware Updatable | Updatable by Consumer by RF |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |