Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

Monitor your home from anywhere with the Z-Wave Plus Flood/Freeze Sensor. When paired with a compatible hub, the smart sensor provides notification when water levels or temperatures change.Trigger eventsThe sensor communicates with your hub to initiate desired actions of Z-Wave devices. Increase peace of mind by automatically turning on lights, sending a notification to your phone, activating an alarm or more when temperatures or water levels change.Detection alarmBuilt-in speaker emits audible alert when water levels or temperatures change to allow immediate action by anyone in the area. Dual functionBase contacts and a detachable probe accommodate various setups. Recessed contacts on the base of the sensor are ideal for placement on flat surfaces. The included probe extends reach for use in wells, sump pump holes and other small spaces. Temperature sensorIn temperature-sensitive spaces, protect against costly damage caused by freezing or overheating. Indicator lightLED indicator displays status and provides feedback during programming. It also serves as notification if tampering with the sensor occurs.Universal compatibilityZ-Wave Plus and all previous Z-Wave generations work together to allow continued expansion of your home-automation network.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 This device supports lifeline and notification (association group 1) supporting 5 nodes.Lifeline association supports the device reset locally function.

Configuration Parameters

Parameter 19: Alternate Exclusion

When enabled, press the button three times quickly when prompted to remove device.
Size: 2 Byte, Default Value: 0

Setting Description
0 Press the button once when prompted to remove device
1 Press the button three times quickly when prompted to remove device

Parameter 21: Reverse detection of wet/dry


Size: 2 Byte, Default Value: 1

Setting Description
1 Normal detection(water detected)
2 Reverse detection(dry detected)

Parameter 22: Temperature Report Interval (When battery operated)


Size: 2 Byte, Default Value: 60

Setting Description
60 Hourly
5 - 60 5-60 Minutes
360 6 Hours
720 12 Hours
1440 Daily

Parameter 23: Battery Report Interval


Size: 2 Byte, Default Value: 1440

Setting Description
5 - 60 5-60 Minutes
360 6 Hours
720 12 Hours
1440 Daily

Parameter 50: Low Temp Alarm

Notification type: Heat = 04Under limit event = 06Under limit non-event = 00
Size: 2 Byte, Default Value: 33

Setting Description
-4 - 122 -4F to 122F
33 33F (Default)

Parameter 51: High Temp Alarm

Notification type: Heat = 04Over limit event = 02Over limit non-event = 00
Size: 2 Byte, Default Value: 104

Setting Description
-4 - 122 -4F to 122F
104 104F (Default)

Parameter 52: Temperature Report Interval (When USB operated)


Size: 2 Byte, Default Value: 60

Setting Description
5 - 60 5-60 Minutes
60 Hourly
360 6 Hours

Parameter 53: Tamper Alert Configuration


Size: 2 Byte, Default Value: 1

Setting Description
1 (Default) - Red LED continuous flash and beeps
2 Red LED flashes once, continuous beeps
3 Red LED continuous flash, no beeps
4 Red LED flash once, no beeps
5 No LED, no beeps

Technical Data

Hardware Platform ZM5101
Device Type Notification Sensor
Network Operation Always On Slave
Firmware Version HW: 255 FW: 5.55
Z-Wave Version 6.81.03
Certification ID ZC10-19106780
Z-Wave Product Id 0x0063.0x4953.0x3236
Color
Frequency XXfrequency
Maximum transmission power XXantenna
Notification Sensor