Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The Z-Wave CO Sensor PSG04 is designed to give early warning of high concentration CO by giving off the alarm sounds from its build-in alarm horn, based on Z-WaveTM technology.It is the Z-WaveTM plus product, it support the security, OTA. Those newest features of the Z-WaveTM technology. Z-WaveTM is a wireless communication protocol designed for home automation, specifically to remotely control applications in residential and light commercial environments. The technology uses a low-power RF radio embedded or retrofitted into home electronics devices and systems, such as lighting, home access control, entertainment systems and household appliances.This product can be included and operated in any Z-WaveTM networkwith other Z-WaveTM certified devices from other manufacturers and/orother applications.All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 4 Used for returned events.

Configuration Parameters

Parameter 1: Auto Report Battery Time

The interval time for auto report the battery level.0 means turn off auto report battery. Each tick means 30 minutes. The default value is 12(6 hours).
Size: 1 Byte, Default Value: 0

Setting Description
0 - 127 Units of 30 minute.

Technical Data

Hardware Platform SD3502
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 1 FW: 1.02:01.02
Z-Wave Version 6.81.03
Certification ID ZC10-19106770
Z-Wave Product Id 0x013C.0x0002.0x0071
Firmware Updatable Not Updatable
Frequency XXfrequency
Maximum transmission power XXantenna
Notification Sensor