The Rehau RE.GUARD is a water manager which protects your home against water leakages and meassures your consumption of water.It has a highly sophisticated water meter and pressure meter built inside. Its algorithms are able to detect very small microleakages as well aslarger leakages like e.g. pipe bursts. The sensibility can be adapted to your needs. Furthermore statistics of your water consumption can be created to help you save water.This product is available at your professional plumber.Made and engineered in Europe
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Connection to Gateway etc. |
2 | 5 | Sends status of valve |
3 | 5 | Sends notiofication in case of leackage |
Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | 0-valve (always) off |
1 | 1-user absent=not at home=holiday |
2 | 2 = user present=at home |
3 | 3 = valve (always) on |
Size: 2 Byte, Default Value: 100
Setting | Description |
---|---|
0 - 32000 | pressure drop in kPa |
for micro leackage Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 - 99 | how many in one time period |
Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 60 | waiting time in minutes between two meassurements |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 2 | 0=disable detection, 1=blink LED, 2= blink LED andshut off valve |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | no leackage |
1 | leackage detected |
Size: 2 Byte, Default Value: 3000
Setting | Description |
---|---|
0 - 32000 | flowrate in l/h |
Size: 2 Byte, Default Value: 1000
Setting | Description |
---|---|
0 - 32000 | pressure drop in kPa |
Size: 2 Byte, Default Value: 300
Setting | Description |
---|---|
0 - 32000 | liter |
Size: 2 Byte, Default Value: 60
Setting | Description |
---|---|
0 - 32000 | time in minutes for water flow in present mode |
Size: 2 Byte, Default Value: 300
Setting | Description |
---|---|
0 - 32000 | max flow rate in absent mode liters/hour |
Size: 2 Byte, Default Value: 1000
Setting | Description |
---|---|
0 - 32000 | max pressure drop in absent mode |
Size: 2 Byte, Default Value: 100
Setting | Description |
---|---|
0 - 32000 | max. liter of water in absent mode |
Size: 2 Byte, Default Value: 30
Setting | Description |
---|---|
0 - 32000 | max. time of water flow in absent mode in minutes |
0=disable detection, 1=blink LED, 2= blink LED and shut off valve Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 - 2 | 0=disable detection, 1=blink LED, 2= blink LED and shut off valve |
0=disable detection, 1=blink LED, 2= blink LED andshut off valve Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 2 | 0=disable detection, 1=blink LED, 2= blink LED andshut off valve |
Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 7 | shows backup battery voltage |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | 0=time not set 1=time set correctly |
Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 2147483647 | Read only: Counting total operation time internally |
Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 2147483647 | Read only counting operation time since last power off |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 23 | hour of day |
minutes in time stamp Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 59 | minute |
Size: 2 Byte, Default Value: 250
Setting | Description |
---|---|
0 - 32000 | 1C = 10; Recommended 25C by international standards |
Size: 2 Byte, Default Value: 20
Setting | Description |
---|---|
0 - 32000 | 1C = 10; Water icing prevention |
error codes; see documentation for Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 37 | showing different error codes. See website for error description |
127 = 1111111 in binary, 0 -> automatic schedule time interval is used, see u0022data_definiton_commentu0022 Size: 1 Byte, Default Value: 127
Setting | Description |
---|---|
1 - 127 | 1111111 in binary, |
Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 168 | How many days |
Size: 2 Byte, Default Value: 100
Setting | Description |
---|---|
0 - 32000 | seconds measuring time |
Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 32000 | presssure drop in kPa |
Hardware Platform | ZM5101 |
Device Type | Valve |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.05:01.06 |
Z-Wave Version | 6.71.03 |
Certification ID | ZC10-19096760 |
Z-Wave Product Id | 0x0413.0x0001.0x0001 |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |