This is a
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
The myTEM Radio Switch Dual is a universal, Z-Wave compatible wall or ceiling switch (ON/OFF) and is used to control two electrical devices (e.g. roller shutters, window blinds, lamps, fans, etc.). The power and energy con-sumption of the connected devices are measured.Two additional digital inputs and the programmable be-havior to the wireless commands allow flexible use in the house. At the same time, the device also serves as a Z-Wave repeater to improve range and stability of the Z-Wave network.The device is intended for installation in a flush-mounted box, e.g. behind light switches or sockets.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus LifelineSystem / Heartbeat; sent periodically (see Configuration Parameter Heartbeat)Power Mangement / Power has been applied; sent after Powerup and ResetMeter / Kilowatt; sent periodically and when values changes (see configuration parameter Send Interval Power and Minimum Delta Power Send)Meter / Kilowatt hours; sent periodically and when values changes (see configuration parameter Send Interval Energy and Minimum Delta Energy Send) |
2 | 5 | Binary Switch Report; sent when the output 1 changes state |
3 | 5 | Binary Switch Report; sent when the output 2 changes state |
4 | 5 | Binary Sensor Report; sent when the input 1 changes state |
5 | 5 | Binary Sensor Report; sent when the input 2 changes state |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
If the notification System Heartbeat is on, a notification report System Heartbeat is sent periodically every 60 minutes (default value). Size: 2 Byte, Default Value: 60
Setting | Description |
---|---|
1 - 1440 | Heartbeat rate [min] |
Period with which the power of output 2 is sent by a Meter Report. Size: 2 Byte, Default Value: 5
Setting | Description |
---|---|
1 - 120 | Interval power [min] |
When the power of output 2 changes this anount the energy value is sent by a Meter Report. Size: 2 Byte, Default Value: 5
Setting | Description |
---|---|
1 - 100 | Minimum delta power [%] |
Together with the mesured current and the Phase shift configuration parameter the Main Voltage confirguation parameter is used to calculate the power of the oututs. Size: 2 Byte, Default Value: 230
Setting | Description |
---|---|
20 - 280 | Main voltage [V] |
Together with the mesured current and the Main Voltage configuration parameter the Phase shift configruation parameter is used to calculate the power of the oututs. Size: 2 Byte, Default Value: 100
Setting | Description |
---|---|
0 - 100 | Phase shift [0.01] |
Period with which the energy of output 1 is sent by a Meter Report. Size: 2 Byte, Default Value: 5
Setting | Description |
---|---|
1 - 120 | Interval energy [min] |
When the energy of output 1 changes this anount the energy value is sent by a Meter Report. Size: 2 Byte, Default Value: 2000
Setting | Description |
---|---|
1 - 50000 | Minimum delta energy [0.001 kWh] |
Period with which the power of output 1 is sent by a Meter Report. Size: 2 Byte, Default Value: 5
Setting | Description |
---|---|
1 - 120 | Interval power [min] |
When the power of output 1 changes this anount the energy value is sent by a Meter Report. Size: 2 Byte, Default Value: 5
Setting | Description |
---|---|
1 - 100 | Minimum dleta power [%] |
Period with which the energy of output 2 is sent by a Meter Report. Size: 2 Byte, Default Value: 5
Setting | Description |
---|---|
1 - 120 | Interval energy [min] |
When the energy of output 2 changes this anount the energy value is sent by a Meter Report. Size: 2 Byte, Default Value: 2000
Setting | Description |
---|---|
1 - 50000 | Minimum delta energy [0.001 kWh] |
Hardware Platform | ZM5101 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.00 |
Z-Wave Version | 6.71.03 |
Certification ID | ZC10-19086712 |
Z-Wave Product Id | 0x034E.0x0001.0x0007 |
Loads Controlled | 2 |
Firmware Updatable | Updatable by Consumer by RF |
Supported Notification Types | Power ManagementSystem |
Supported Meter Type | Electric Energy |
Electric Load Type | ELV (Electronic)IncandescentInductive (e.g. Motor) |
Security V2 | S2_UNAUTHENTICATED ,S2_AUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |