This is a secure On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

Touch switch is an in-wall switchgear based on Z-Wave wireless radio frequency technology for intelligent control. This product can be added to the gateway or PC controller supporting Z-Wave Plus, remotely controlled through the APP interface, or manually controlled by the touch. In addition, the product also supports the scene mode, the user can configure the scene through the APP, combine various devices in the same scene, and run the scene function through the APP or manually.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plus Lifeline
2 5 scene control
3 5 Endpoint 1: Switch status report
4 5 Endpoint 2: Switch status report

Configuration Parameters

Parameter 21: Setting device status after power failure

Define how the Switch reacts after the power supply is back on.
Size: 1 Byte, Default Value: 0

Setting Description
0 Touch Switch memorizes its state after a power failure.
1 Touch Switch does not memorize its state after a power failure. Connected device will be on after the power supply is reconnected.
2 Touch Switch does not memorize its state after a power failure. Connected device will be off after the power supply is reconnected.

Parameter 24: Notification when Load status change

Touch Switch can send notifications to association device when state of Touch Switchs load change.
Size: 1 Byte, Default Value: 1

Setting Description
0 The function is disabled.
1 Send Switch binary report.
2 Send Switch binary report only when Load condition is not changed by Z-WAVE Command.

Technical Data

Hardware Platform ZM5202
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.00
Z-Wave Version 6.81.03
Certification ID ZC10-19086710
Z-Wave Product Id 0x041A.0x0100.0x0003
Color White
Z-Wave Scene Type Scene & Central Scene
Switch Type Push Button with Indicator
Loads Controlled 2
Firmware Updatable Updatable by Consumer via Internet
Electric Load Type Dimmable ELV (Magnetic)Dimmable FluorescentDimmable LEDDimmable MLV (Magnetic)ELV (Electronic)FluorescentIncandescentInductive (e.g. Motor)LEDMLV (Magnetic)
Communications Protocol Z-Wave Serial API
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)On/Off Power Switch