Quickstart

This is a secure Light Dimmer Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.Each module is designed to act as a repeater,which will re-transmit a radio frequency (RF) signal by routing the signal ,around obstacles and radio dead spots to ensure that the signal is received at its intended destination.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Z-Wave Plus Lifeline
2 5 basic set command

Configuration Parameters

Parameter 1: Locally Button function

Locally Button function
Size: 1 Byte, Default Value: 0

Setting Description
0 Up Button ON,Down Button OFF
1 Up Button OFF,Down Button ON
2 Up Button: On/OffDown Button: On/Off

Parameter 10: Multilevel minimumvalue can be set

Multilevel minimumvalue can be setThe minimum luminance value of the dimmingLocal Button
Size: 1 Byte, Default Value: 1

Setting Description
0 - 99 Multilevel minimumvalue can be setThe minimum luminance value of the dimmingLocal Button

Parameter 11: Multilevel maxmum value can be set

Multilevel maxmum value can be setThe maxmum luminance value of the dimmingLocal Button
Size: 1 Byte, Default Value: 0

Setting Description
0 - 99 Multilevel maxmum value can be setThe maxmum luminance value of the dimmingLocal Button

Parameter 12: quickly press UPPER paddle 2 times

when switch is off and quickly press UPPER paddle 2 times, switch turns on to x brightness Local Button
Size: 1 Byte, Default Value: 0

Setting Description
0 Turn ON to 99
1 turn on to the value relate

Parameter 14: Double Tap Behavior

Double Tap Behavior
Size: 1 Byte, Default Value: 0

Setting Description
0 enable double tap to full brightness
1 disable double tap to full brightness, single tap to last brightness level
2 disable double tap to full brightness, single tap always to full brightness

Parameter 15: Enable or Disable local control

Enable or Disable local control
Size: 1 Byte, Default Value: 1

Setting Description
0 disable
1 enable

Parameter 2: Status LED Configuration

Status LED Configuration
Size: 1 Byte, Default Value: 0

Setting Description
0 Output and the LED are in the different state.
1 Output and the LED are in the same state.
2 Always OFF
3 Always ON

Parameter 3: Enable Auto Turn-OFF Timer

Enable Auto Turn-OFF Timer
Size: 1 Byte, Default Value: 0

Setting Description
0 Auto Turn-OFF Timer Disabled
1 Auto Turn-OFF Timer Enabled

Parameter 4: Count Down Configuration

Count Down Configuration(Turn off the output by time
Size: 4 Byte, Default Value: 60

Setting Description
1 - 65535 Count Down Configuration(Turn off the output by time

Parameter 5: Enable Auto Turn-ON Timer

Enable Auto Turn-ON Timer
Size: 1 Byte, Default Value: 0

Setting Description
0 Auto Turn-ON Timer Disabled
1 Auto Turn-ON Timer Enabled

Parameter 6: Count Down Configuration

Count Down Configuration(Turn ON the output by time
Size: 4 Byte, Default Value: 60

Setting Description
1 - 65535 Count Down Configuration(Turn ON the output by time

Parameter 7: Association Setting Parameter

Association Setting Parameter
Size: 1 Byte, Default Value: 15

Setting Description
0 None
1 Local
2 3-way
3 3-way&Local
4 Z-Wave hub
5 Z-Wave hub&Local
6 Z-Wave hub&3-way
7 Z-Wave hub&Local&3-way
8 Timer
9 Timer&Local
10 Timer&3-way
11 Timer&3-way&Local
12 Timer&Z-Wave hub
13 Timer&Z-Wave hub&Local
14 Timer&Z-Wave hub&3-way
15 ALL

Parameter 8: Restores state after power failure

Restores state after power failure
Size: 1 Byte, Default Value: 2

Setting Description
0 Output OFF.
1 Output ON
2 The state before a power outage.

Parameter 9: Dimmer Speed Parameter Local Button

Dimmer Speed Parameter Local Button
Size: 1 Byte, Default Value: 1

Setting Description
1 - 99 from 0x63 to 0x00 or from 0x00 to 0x63 need XXs

Technical Data

Hardware Platform ZM5202
Device Type Light Dimmer Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.00
Z-Wave Version 6.81.03
Certification ID ZC10-19086704
Z-Wave Product Id 0x0312.0xA000.0xAA02
Z-Wave Scene Type Scene
Switch Type Toggle
Firmware Updatable Updatable by Consumer by RF
Electric Load Type Dimmable LEDIncandescent
Color White
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoLight Dimmer Switch