Quickstart

This is a secure On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The myTEM Radio Switch Dual Plus is a universal, Z-Wave compatible wall or ceiling switch (ON/OFF) and is used to control two electrical devices. Two additional digital inputs and the programmable behav-ior to the wireless commands allow flexible use in the house. Optionally, a myTEM Touch Add-on control panel can be attached to the connector.The device is intended for installation in a flush-mounted box.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plus LifelineSystem / Heartbeat; sent periodically (see Configuration Parameter Heartbeat)Power Mangement / Power has been applied; sent after Powerup and Reset
2 5 Binary Switch Report; sent when the output 1 changes state
3 5 Binary Switch Report; sent when the output 2 changes state
4 5 Binary Sensor Report; sent when the input 1 changes state
5 5 Binary Sensor Report; sent when the input 2 changes state

Configuration Parameters

Parameter 1: Heartbeat Rate

If the notification System Heartbeat is on, a notification report System Heartbeat is sent periodically every 60 minutes (default value).
Size: 2 Byte, Default Value: 60

Setting Description
1 - 1440 Heartbeat rate [min]

Parameter 2: Send Interval Temperature

Period with which the measured temperature is sent by a Multilevel Sensor Report.
Size: 2 Byte, Default Value: 30

Setting Description
1 - 120 Send interval temperature [min]

Parameter 3: Minum Delta Temperature Send

When the temperature changes this anount the temperature value is sent by a Multilevel Sensor Report.
Size: 2 Byte, Default Value: 5

Setting Description
1 - 100 Minimum delta temperature [0.1 K]

Parameter 4: Send Interval Humidity

Period with which the measured humidity is sent by a Multilevel Sensor Report.
Size: 2 Byte, Default Value: 30

Setting Description
1 - 120 Send interval humidiy [min]

Parameter 5: Minimum Delta Humidity Send

When the humidity changes this anount the temperature value is sent by a Multilevel Sensor Report.
Size: 2 Byte, Default Value: 10

Setting Description
10 - 1000 Minimum delta humidity [0.1 %]

Technical Data

Hardware Platform ZM5101
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.00
Z-Wave Version 6.71.03
Certification ID ZC10-19076686
Z-Wave Product Id 0x034E.0x0001.0x0008
Electric Load Type ELV (Electronic)IncandescentInductive (e.g. Motor)
Loads Controlled 2
Supported Notification Types Power ManagementSystem
Firmware Updatable Updatable by Consumer by RF
Switch Type Push Button
Color White
Sensors Air TemperatureHumidity
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)On/Off Power Switch