This is a
KONOzw is the smart hub thermostat made with you in mind. It seamlessly connects to many smart hubs and blends in or stands out with its interchangeable Dcorsnap covers. KONOzw makes it easier than ever to personalize your comfort, dcor, and savings.
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline |
User Temperature Calibration. For example, sending a value of +50 means the calibration offset is +0.5F Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
-250 - 250 | Step-size = 10 |
Size: 2 Byte, Default Value: 95
Setting | Description |
---|---|
60 - 95 | Increment by 1F. The actual allowable range is dependent on the heat set point limit |
Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
50 - 75 | Increment by 1F. The actual allowable range is dependent on the heat set point limit |
Temperature Minimum Setpoint Deadband. For example, setting the value to 200 means the deadband is +2.0F Size: 2 Byte, Default Value: 200
Setting | Description |
---|---|
100 - 250 | Step-size = 10 |
Degree of change in ambient temperature in order to trigger the sending of temperature report Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
50 | 0.5F |
100 | 1.0F |
150 | 1.5F |
200 | 2.0F |
250 | 2.5F |
300 | 3.0F |
350 | 3.5F |
400 | 4.0F |
Regular Ambient Temperature Reporting Interval Size: 1 Byte, Default Value: 4
Setting | Description |
---|---|
1 - 24 | 1-24 hours |
Regular Operating State Reporting Interval Size: 1 Byte, Default Value: 4
Setting | Description |
---|---|
1 - 24 | 1-24 hours |
Command Echo for- Thermostat Mode- Thermostat Fan mode- Thermostat Setpoint Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
Temperature Unit (C/F) Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Celsius |
1 | Fahrenheit |
Available Control mode Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Heat and Cool, Auto |
1 | Heat Only |
2 | Cool Only |
3 | Heat and Cool, no Auto |
4 | reserved |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Furnace Gas |
1 | Furnace Electric |
2 | Heat Pump |
3 | Boiler no fan |
4 | reserved |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | O-valve |
1 | B-valve |
Size: 2 Byte, Default Value: 90
Setting | Description |
---|---|
60 - 90 | Increment by 1F |
Size: 2 Byte, Default Value: 45
Setting | Description |
---|---|
45 - 60 | Increment by 1F |
Hardware Platform | ZM5202 |
Device Type | Thermostat - HVAC |
Network Operation | Always On Slave |
Firmware Version | HW: 2 FW: 1.00:00.114 |
Z-Wave Version | 6.71.03 |
Certification ID | ZC10-19076681 |
Z-Wave Product Id | 0x0411.0x0001.0x2111 |
Thermostat Power Source | |
Sensors | |
Loads Controlled | |
Thermostat Modes | |
Color | |
Firmware Updatable | |
Thermostat HVAC Systems Supported | |
Supported Notification Types | |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |