Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

Aeotec Door/ Window Sensor 7 is a small window position sensor for your smart home, it monitors window and their exact opening position and lets your know when a window is tilted or completely opened. It also supports connecting external binary sensors through the dry binary contact of the Door/ Window sensor.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plus Lifeline
2 5 Control devices when magnet or external dry contacts trips
3 5 Sends our alarm message when magnet controlled or external dry sensor trips.
4 5 Sends alarm messages when tamper is tripped

Configuration Parameters

Parameter 1: Sensor Operation Mode

This parameter defines if the internal magnet sensor or the external terminal input is detected and used to issue alarm notification. There is always one input active only. The other sensor input the deactivated.
Size: 1 Byte, Default Value: 0

Setting Description
0 Internal Magnet Sensor Used
1 External Terminal Inputs Used

Parameter 10: Time Delay of Off command frame

Off command is sent after a delay defined in this parameter.
Size: 2 Byte, Default Value: 0

Setting Description
0 - 32400 seconds

Parameter 11: Delay of Tamper Alarm Cancellation

Time a tamper alarm is delayed.
Size: 2 Byte, Default Value: 0

Setting Description
0 - 32400 seconds

Parameter 12: Reporting Tamper Alarm Cancellation

This parameter defines if the alarm cancellation event is reported.
Size: 1 Byte, Default Value: 1

Setting Description
0 Do not send Report
1 Send Report

Parameter 13: Central Scene Event Functionality

This parameter enables/disablesthe central scene function.
Size: 1 Byte, Default Value: 0

Setting Description
0 Disabled
1 Enabled

Parameter 14: Tilt Sensor Functionality

This parameter enables/disablesthe tilt function.
Size: 1 Byte, Default Value: 1

Setting Description
0 Disabled
1 Enabled

Parameter 2: Sensor State Polarity

This parameter defines the polarity of the magnet sensor.
Size: 1 Byte, Default Value: 0

Setting Description
0 Closed when Magnet in proximity
1 Opened when Magnet in proximity

Parameter 3: Visual LED Indications

This parameter defines when the red LED will indicate events. Disabling all indications may extend battery life.
Size: 1 Byte, Default Value: 7

Setting Description
1 No Indications
2 Open/Close Status Change
4 Wake Up
16 Device Tampering

Parameter 4: Range Test after double click

Allows to enable the activation of a Z-Wave range test with double clicking the tamper switch.
Size: 1 Byte, Default Value: 0

Setting Description
0 Disabled
1 Enabled

Parameter 5: 2nd Association Group Trigger

his parameter defines the status of the magnet switch that causes sending a BASIC command to all devices of Association Group 2.
Size: 1 Byte, Default Value: 0

Setting Description
0 Switch after Open and Close
1 Switch after Open
2 Switch after Close

Parameter 6: Command Sent to Devices of Association Group 2

This parameter defines which commands is sent to 2nd Association Group
Size: 1 Byte, Default Value: 2

Setting Description
0 On
1 Off
2 On and Off

Parameter 7: BASIC command value sent to 2nd Association Group on On event

This is the BASIC command value sent in case of On event.
Size: 1 Byte, Default Value: -1

Setting Description
-1 Value
0 - 99 Value

Parameter 8: BASIC command value sent to 2nd Association Group on Off event

This is the BASIC command value sent in case of Off event.
Size: 1 Byte, Default Value: 0

Setting Description
-1 Value
0 - 99 Value

Parameter 9: Time Delay of Off command frame

Off command is sent after a delay defined in this parameter.
Size: 2 Byte, Default Value: 0

Setting Description
0 - 32400 seconds

Technical Data

Hardware Platform ZM5101
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 1 FW: 1.00
Z-Wave Version 6.81.01
Certification ID ZC10-19076678
Z-Wave Product Id 0x0371.0x0202.0x0007
Sensors Open/Closed (Binary)
Firmware Updatable Updatable by Consumer by RF
Color White
Supported Notification Types Access ControlHome SecurityPower Management
Frequency XXfrequency
Maximum transmission power XXantenna
Australia / New ZealandNotification Sensor