When the pushbutton is released after a press of (2sec
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Socket iO is ready to operate with Z-Wave controllers and configured to be managed by Simon100 iO APP using the HUB plug iO for getting a better user experience. allowing the control of the socket and LEDs integrated.Available colors Black and White.visit http://www.simon.es/simon100/ to learn more about Simon 100 iO.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
When the pushbutton is released after a press of (30sec
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 3 | Z-Wave Plus LifelineCOMMAND_CLASS_BASIC_REPORTIt is sent to the associated nodes when the loadchanges state:ON -> 0xFFOFF -> 0x00COMMAND_CLASS_METER_REPORT_V4It is sent to the associated nodes when the powerconsumed varies more than 10%Electric meter, Consumed, Watts, Size 4, Precision 1, Value (W)COMMAND_CLASS_DEVICE_RESET_LOCALLY_NOTIFICATIONThe associated nodes are sent when the device isremoved from the Z-Wave network |
2 | 20 | CtrlCOMMAND_CLASS_BASIC_REPORTIt is sent to the associated nodes when the loadchanges state:ON -> 0xFFOFF -> 0x00 |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Allows to turn ON or OFF the central LED Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Turns the LED OFF |
255 | Turns the LED ON |
Sets the delay time to turn on the device Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disables timing |
1 - 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution |
128 - 255 | 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution |
Sets the time the device stays on Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disables timing |
1 - 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution |
128 - 255 | 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution |
Locks or Unlocks the direct control of the load Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Enables the push button to control the load |
255 | Disables the action of the push button of the load |
Resets groups, Z-Wave status, and some or all configurations depending on the configuration value (write only) Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
39015 | Parameters, Groups, and Z-Wave status are restored to default. |
17170 | Parameters, except Lock long press are restored to default |
Sets the delay time to turn off the device Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disables timing |
1 - 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution |
128 - 255 | 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution |
Controls the state of the load after a reset action Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 | Restart with the relay disabled. |
255 | Recover the previous state. |
Controls the behavior of the product when the key is pressed Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | When short press, device toggles the load |
1 | When short press, device turns ON the load. When hold press from 2 seconds to 10 seconds device turns OFF the load. The Slider does not works.With this configuration, the device will not send the Node Info neither Show the LEDs feedback with this press action |
2 | When short press, device turns OFF the load |
Allows to set a power consumption limit in Watts Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disables custom consumption limit |
1 - 65535 | Sets the power in Watts that is supported |
Allows to identify a product using its central LED (write only) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
255 | the central LED blinks for 5 seconds in order to identify the device |
Reports the state of the charge (read only) Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
45056 | Load is OFF |
45057 | Load is ON |
45312 | Load is OFF |
45567 | Load is ON |
Locks or unlocks the long press on the key Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Long press works as described previously |
255 | Long press from 2 seconds to 30 seconds does not send a Node info. With a long press above 30 seconds, all parameters except Lock long press are restored to default and device sends a Node info |
Enables or disables the beacon function Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disables beacon function |
1 - 99 | Set the intensity of the beacon LEDs |
Hardware Platform | ZM5202 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 4.24:68.49 |
Z-Wave Version | 6.51.07 |
Certification ID | ZC10-19076674 |
Z-Wave Product Id | 0x0267.0x0009.0x0000 |
Firmware Updatable | Updatable by Professional/Technician |
Neutral Wire Required | ok |
Switch Type | Toggle |
Supported Meter Type | |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |