Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. To add this device to your network execute the following action:
Press the operating switch once and release it within about 2 seconds, then registration operation is started and the LED lights for about 30 seconds.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

This device is for KDDI IOT services only.This product is KAIHEISENSOR 03 that detects door and window open/close, temperature, humidity, and illumination.It detects the state change of the place where the product is installed and notifies the controller.It's possible to install it in the various places because a thin magnet is adopted.

Reset to factory default Use this procedure only in the event that the primary controller is lost. All the set values and the controller information are cleared to return to the factory default.1. Hold down the operating switch for about 10 seconds. The LED comes on when initialization starts.2. Release the operating switch when the LED comes on.The initialization is complete when the LED goes out.
Inclusion Press the operating switch once and release it within about 2 seconds, then registration operation is started and the LED lights for about 30 seconds.
Exclusion Press the operating switch once. The LED comes on and then goes out.
NIF XXXNIF
Wakeup Press the operating switch twice consecutively. The sensor wakes from the sleep state, and sends WAKE UP NOTIFICATION.It will automatically enter the sleep state upon completion of sending/receiving with the controller.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Z-Wave Plus Lifeline

Configuration Parameters

Parameter 1: LED

LED Setting, Whether to Enable/Disable lighting at sending.
Size: 1 Byte, Default Value: 0

Setting Description
0 Disable
1 Enable

Parameter 2: Temperature

Temperature Setting - Threshold value.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 7 Value desired (1 to 9 C in increments of 1C)

Technical Data

Hardware Platform ZM5202
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 1 FW: 1.01:01.01
Z-Wave Version 6.81.03
Certification ID ZC10-19076671
Z-Wave Product Id 0x0427.0x0001.0x0001
Supported Notification Types Access Control
Sensors Air TemperatureHumidityLuminanceOpen/Closed (Binary)
Frequency XXfrequency
Maximum transmission power XXantenna
JapanNotification Sensor