This is a
This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufactures and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.1. Insert the 3V CR123A Lithium battery into the battery compartment connecting the correct polarity as shown on the battery compartment lid.2. Put the Z-Wave gateway or control panel into Inclusion or Learning mode (please refer to the Z-Wave gateway or control panel manual).3. Within 1 second, press the Function Button 3 times. 4. Refer to the operation manual of the Z-Wave gateway or control panel to complete the learn-in process.5.If the sensor has already been included (learnt) into another Z-Wave Gateway/Control Panel, or if the sensor is unable to be learnt into the current Z-Wave Gateway/Control Panel, please exclude it first (see Exclusion) before attempting to include it into the current Z-Wave Gateway/Control Panel.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
ACGS-23ZW Acoustic Glassbreak Sensor is an excellent first line of defense for perimeter protection. This wireless sensor will alert when a glass window or door is being smashed or broken, providing an extra layer of advanced security for your property.Our proprietary microphone technology recognizes acoustic patterns to provide full coverage, with a maximum of 8m radius from sensor to glass. With four selectable sensitivity levels, ACGS-23ZW can be easily adjusted to fit large or small rooms. It can also be integrated into security system to activate a siren upon glass break, thereby detering burglars and preventing a full break-in.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
Factory Reset(Only use factory reset when network Control Panel/Gateway is missing or inoperable).1. Remove the batteries of the Glass Break Detector first.2. Press and hold the Function Button. While holding the Function Button, power on the Glass Break Detector by re-inserting the batteries, wait for 10 seconds to factory reset.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
This device is battery operated and turned into deep sleep state most of the time to save battery life time. Communication with the device is limited. In order to communicate with the device, a static controller C is needed in the network. This controller will maintain a mailbox for the battery operated devices and store commands that can not be received during deep sleep state. Without such a controller, communication may become impossible and/or the battery life time is significantly decreased.
This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification. The controller can then empty the mailbox. Therefore, the device needs to be configured with the desired wakeup interval and the node ID of the controller. If the device was included by a static controller this controller will usually perform all necessary configurations. The wakeup interval is a tradeoff between maximal battery life time and the desired responses of the device. To wakeup the device please perform the following action: This function uses the Z-Wave Wake Up Command Class. The Wake Up Command Class allows the battery-powered Glass Break Detector to notify the Control Panel/Gateway that it is awake and ready to receive any queued commands. The wake up time is programmed automatically according to Control Panels setting when The Glass Break Detector is included. The recommended setting of the wake up time is 60 minutes above.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Group 1 for LifeLine (max node = 1):Notification CC,V3 (COMMAND_CLASS_NOTIFICATION)Battery CC (COMMAND_CLASS_BATTERY)Device Reset Locally CCNotification Report1. If Glass Break Detector is triggered, it will send a Notification Report (Type: 0x07, Event 0x06).2. If tamper is open, it will send Notification Report (Type: 0x07, Event: 0x03)3. If tamper is closed, it will send Notification Report (Type: 0x07, Event: 0x00, Parmeter:0x03).Battery Report1. If battery level changes, it will send Battery Report (0x64, 0x4B, 0x32, 0x19, or 0xFF) respectively.0x64 --- 100% Battery Full0x4B --- 75% Battery0x32 --- 50% Battery0x19 --- 25% Battery0xFF --- Battery Dead (Cut Off)Device Reset1. To perform factory reset, press and hold the Function Button for 10 seconds, the device will send a DEVICE_RESET_LOCALLY_NOTIFICATION report. |
2 | 1 | Group 2 for Basic Set (max node = 1):BASIC CC (COMMAND_CLASS_BASIC)1. When the detector is triggered, it will send BASIC SET (0xFF). The device does NOT support Restore Event report. |
Hardware Platform | ZM5202 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 255 FW: 4.01 |
Z-Wave Version | 6.81.04 |
Certification ID | ZC10-19066571 |
Z-Wave Product Id | 0x018E.0x0003.0x000E |
Firmware Updatable | Updatable by Consumer by RF |
Supported Notification Types | Home Security |
Security V2 | S2_UNAUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |