This is a
Yale nexTouch electrified trim for Yale and competitor rim exit devices with Push Button keypad and supporting modular radio technology
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Z-Wave Plus Lifeline |
Level control, 1 = High Volume, 2 = Low Volume, 3 = Silent. Default is 2 or Low Volume Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 - 3 | Sound level |
0x00 = OFF, 0xFF = ON default is 0xFF or ON. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-128 | One Touch Locking On |
0 | One Touch Locking Off |
0x00 = OFF, 0xFF = ON default is 0x00 or OFF Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-128 | Privacy Button On |
0 | Privacy Button Off |
0x00 = OFF , 0xFF=ON default is 0x00 or OFF Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-128 | Lock Status LED On |
0 | Lock Status LED Off |
01 = Lock will execute Reset To Factory.No default value Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-128 | Reset to Factory ON |
0 | Reset to Factory Off |
10 to 2540 second. This value is represented as seconds X 10. (ie a value of 4 would mean a door propped timer of 40 seconds) Set to 0x00 to disable Door Propped Alarm. Default = 0x00 (off)Additional hardware required. These parameters are only active if the optional Door Position Switch has been installed with the lock. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
10 - 2540 | Seconds |
0x00 = OFF, 0xFF = ON Default is 0x00 or off.Used to enable/disable door condition alarms for locks that support a door position sensor. Any lock that does not support DPS will always report 0x00.Additional hardware required. These parameters are only active if the optional Door Position Switch has been installed with the lock. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-128 | DPS Alarm |
0x00 = OFF, 0xFF = ON default is 0x00 or OFF Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-128 | Auto Relock On |
0 | Auto Relock OFF |
0x00 = OFF, 0xFF = ON default is 0x00 or OFFIf supported switches lock to lower power mode of operation with reduced sound and led brightness. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-128 | Eco Mode on |
0 | Eco Mode Off |
10 to 180 seconds default is 30 seconds Size: 1 Byte, Default Value: 30
Setting | Description |
---|---|
10 - 180 | Seconds |
3 to 10 default is 5 times Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
3 - 10 | Times |
1=English, 2=Spanish, 3=French default is 1= English Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | English |
2 | Spanish |
3 | French |
10 to 180 seconds default is 30 seconds Size: 1 Byte, Default Value: 60
Setting | Description |
---|---|
10 - 180 | Seconds |
00 = normal mode (this is the default mode)01 = vacation mode, keypad lockout02 = privacy mode, no keypad. RF Unlock will work Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Normal Mode |
1 | Vacation Mode |
2 | Privacy Mode |
Hardware Platform | ZM5101 |
Device Type | Door Lock - Keypad |
Network Operation | Listening Sleeping Slave |
Firmware Version | HW: 255 FW: 1.78:25.00 |
Z-Wave Version | 6.51.07 |
Certification ID | ZC10-19066561 |
Z-Wave Product Id | 0x0129.0x8009.0x0C00 |
IP (Ingress Protection) Rated | ok |
Sensors | Open/Closed (Binary) |
Door Lock Type | Deadbolt Motor Attachment |
Supported Notification Types | Access ControlHome SecurityPower Management |
Firmware Updatable | Updatable by Consumer by RF |
Outdoor Use | ok |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |