Quickstart

This is a secure Door Lock - Keypad for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

Yale nexTouch electrified trim for Yale and competitor rim exit devices with Push Button keypad and supporting modular radio technology

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Z-Wave Plus Lifeline

Configuration Parameters

Parameter 1: Silent Mode on/off

Level control, 1 = High Volume, 2 = Low Volume, 3 = Silent. Default is 2 or Low Volume
Size: 1 Byte, Default Value: 1

Setting Description
1 - 3 Sound level

Parameter 11: One Touch Locking

0x00 = OFF, 0xFF = ON default is 0xFF or ON.
Size: 1 Byte, Default Value: 0

Setting Description
-128 One Touch Locking On
0 One Touch Locking Off

Parameter 12: Privacy Button

0x00 = OFF, 0xFF = ON default is 0x00 or OFF
Size: 1 Byte, Default Value: 0

Setting Description
-128 Privacy Button On
0 Privacy Button Off

Parameter 13: Lock Status LED

0x00 = OFF , 0xFF=ON default is 0x00 or OFF
Size: 1 Byte, Default Value: 0

Setting Description
-128 Lock Status LED On
0 Lock Status LED Off

Parameter 15: Reset to Factory Defaults

01 = Lock will execute Reset To Factory.No default value
Size: 1 Byte, Default Value: 0

Setting Description
-128 Reset to Factory ON
0 Reset to Factory Off

Parameter 18: Door Propped Timer

10 to 2540 second. This value is represented as seconds X 10. (ie a value of 4 would mean a door propped timer of 40 seconds) Set to 0x00 to disable Door Propped Alarm. Default = 0x00 (off)Additional hardware required. These parameters are only active if the optional Door Position Switch has been installed with the lock.
Size: 1 Byte, Default Value: 0

Setting Description
10 - 2540 Seconds

Parameter 19: DPS Alarms

0x00 = OFF, 0xFF = ON Default is 0x00 or off.Used to enable/disable door condition alarms for locks that support a door position sensor. Any lock that does not support DPS will always report 0x00.Additional hardware required. These parameters are only active if the optional Door Position Switch has been installed with the lock.
Size: 1 Byte, Default Value: 0

Setting Description
-128 DPS Alarm

Parameter 2: Auto Relock on/off

0x00 = OFF, 0xFF = ON default is 0x00 or OFF
Size: 1 Byte, Default Value: 0

Setting Description
-128 Auto Relock On
0 Auto Relock OFF

Parameter 21: Eco Mode on/off

0x00 = OFF, 0xFF = ON default is 0x00 or OFFIf supported switches lock to lower power mode of operation with reduced sound and led brightness.
Size: 1 Byte, Default Value: 0

Setting Description
-128 Eco Mode on
0 Eco Mode Off

Parameter 3: Relock Time

10 to 180 seconds default is 30 seconds
Size: 1 Byte, Default Value: 30

Setting Description
10 - 180 Seconds

Parameter 4: Wrong Code Entry Limit

3 to 10 default is 5 times
Size: 1 Byte, Default Value: 5

Setting Description
3 - 10 Times

Parameter 5: Language

1=English, 2=Spanish, 3=French default is 1= English
Size: 1 Byte, Default Value: 1

Setting Description
1 English
2 Spanish
3 French

Parameter 7: Shut Down Time (After wrong codes)

10 to 180 seconds default is 30 seconds
Size: 1 Byte, Default Value: 60

Setting Description
10 - 180 Seconds

Parameter 8: Operating Mode

00 = normal mode (this is the default mode)01 = vacation mode, keypad lockout02 = privacy mode, no keypad. RF Unlock will work
Size: 1 Byte, Default Value: 0

Setting Description
0 Normal Mode
1 Vacation Mode
2 Privacy Mode

Technical Data

Hardware Platform ZM5101
Device Type Door Lock - Keypad
Network Operation Listening Sleeping Slave
Firmware Version HW: 255 FW: 1.78:25.00
Z-Wave Version 6.51.07
Certification ID ZC10-19066561
Z-Wave Product Id 0x0129.0x8009.0x0C00
IP (Ingress Protection) Rated ok
Sensors Open/Closed (Binary)
Door Lock Type Deadbolt Motor Attachment
Supported Notification Types Access ControlHome SecurityPower Management
Firmware Updatable Updatable by Consumer by RF
Outdoor Use ok
Frequency XXfrequency
Maximum transmission power XXantenna
Door Lock - Keypad