Quickstart

This is a secure On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
To add the device to the Z-Wave network:1.Keep the device in Z-Wave range.2.Power the device.3.Set the main controller in (Security/non-Security Mode) add mode(see the controllers manual).4.Quickly, three times press the Config Button, LED color will change from Red to Blue.5.Wait for the adding process to end.6.Successful adding will be confirmed by the Z-Wave controllersMessage and LED Colour will change to Green.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

JR automation 4 channel relay is designed for wireless home automation solution with Z-Wave technology. It communicates with all the Z- wave based controller with 2-way feedback with wireless communication. For the Indian market, it installs in all the 4 or more-module back box. It works for all type of load to turn ON and OFF like Fan, Lights, LED, Bulb and heavy-duty load (like AC, Geyser by using intermediate relays) by each of 6A load current capacity. It also works to increase the range of Z-Wave mess network as Z-Wave repeater. Due to 4 channel relays together its very perfect for Indian market requirement with lower cost and without any changes in the normal switchboard. The encryption mode that the switch supports is S2 Unauthenticated.

Reset to factory default Reset procedure allows restoring the device back to its factory settings, which means all information about the Z-Wave controller will be deleted.1.Press and Hold Config Button for 10 sec until White LED Indication to start blinking.2.Release Config button. Now you have 5sec to Reset Device otherwise it back to Normal Mode.3.Single Click Config Button.4.After a few seconds, the device will be restarted, which is signaledwith the red LED indicator color.NOTE:- Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Inclusion To add the device to the Z-Wave network:1.Keep the device in Z-Wave range.2.Power the device.3.Set the main controller in (Security/non-Security Mode) add mode(see the controllers manual).4.Quickly, three times press the Config Button, LED color will change from Red to Blue.5.Wait for the adding process to end.6.Successful adding will be confirmed by the Z-Wave controllersMessage and LED Colour will change to Green.
Exclusion To remove the device from the Z-Wave network:1.Power the device.2.Set the main controller into remove mode (see the controllers manual).3.Quickly, three times click the Config button LED color will change to Blue.4.Wait for the removing process to end.5.Successful removing will be confirmed by the Z-Wave controllers message and Red LED color.
NIF XXXNIF
Wakeup JR-4C01 is powered using an AC power supply unit so it is always awake.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Name: Lifeline Command: Device Reset Locally Notification Switch Binary Report
2 5 Name: JRS-1 Command: Basic Set Send Basic Set command to the other node in this association group when active endpoint 1.
3 5 Name: JRS-2 Command: Basic Set Send Basic Set command to the other node in this association group when active endpoint 2.
4 5 Name: JRS-3 Command: Basic Set Send Basic Set command to the other node in this association group when active endpoint 3.
5 5 Name: JRS-4 Command: Basic Set Send Basic Set command to the other node in this association group when active endpoint 4.

Technical Data

Hardware Platform ZM5101
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 4.01
Z-Wave Version 6.81.03
Certification ID ZC10-19066559
Z-Wave Product Id 0x0426.0x0003.0x0001
Neutral Wire Required ok
Electric Load Type FluorescentIncandescentLED
Firmware Updatable Updatable by Professional/Technician
Color Black
Loads Controlled 4
Frequency XXfrequency
Maximum transmission power XXantenna
IndiaOn/Off Power Switch