Quickstart

This is a secure Door Lock - Keypad for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

A module enabling your ID Lock digital door lock to a Z-Wave Plus enabled digital door Lock.The module is compatible with ID Lock 150.It enables your ID Lock to operate in a Z-Wave network with numerous access control funtions and notifications.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plus Lifeline

Configuration Parameters

Parameter 1: Away and lock mode

Away mode off or onAuto or Manual Lock modeIn auto Lock mode the door Locks Three Seconds after closing the door.In manual Lock mode the door Locks when pressing O/C button or activating touchpanel.When away mode is on the inside O/C button is deactivated.
Size: 1 Byte, Default Value: 1

Setting Description
0 Away mode off - Manual lock mode
1 Away mode off - Auto lock mode
2 Away mode on - Manual lock mode
3 Away mode on - Auto lock mode

Parameter 3: Hinge direction (Right or Left)

Direction of hinges on door.To find your correct settings look at the mounted door lock outside. If the door hinges are on the right side of the door correct setting is u0022Rightu0022. If the door hinges are on the left side of the door correct setting is u0022Leftu0022.
Size: 1 Byte, Default Value: 0

Setting Description
0 Right hinged door
1 Left hinged door

Parameter 4: Door lock audio volume

Setting for audio volume of notifications on door lock operations.
Size: 1 Byte, Default Value: 5

Setting Description
0 - 6 Sound volume level 0 to 6

Parameter 5: ReLock mode

ReLock mode is factory default on.ReLock is the security function relocking the door lock 7 seconds after a valid unlock if the door is not opened.When ReLock is off, the door lock will remain unlocked untill a new lock door operation (i.e. pressing O/C-button, activating touch panel or closing the door if auto lock mode).
Size: 1 Byte, Default Value: 1

Setting Description
0 ReLock mode off
1 ReLock mode on

Parameter 6: Service PIN Mode

The service PIN on ID Lock 150 will be enabled or disabled according to this configuration setting. By default the Service PIN Mode is 0=Deactivated.It can be set to either 1, 2, 5 or 10 times, 12 hours, 24 hours, always valid or disabled (FE).Service PIN is identifier 108.
Size: 1 Byte, Default Value: 0

Setting Description
0 Deactivated
1 Valid 1 time
2 Valid 2 times
3 Valid 5 times
4 Valid 10 times
8 Valid 12 hours
9 Valid 24 hours
7 Always valid

Parameter 7: Door lock model

This configuration is only available through the configuration get command.If the configuration report is 65(101), door lock model type is ID Lock 101.If the configuration report is 96(150), door lock model type is ID Lock 150.ID Lock 101 cannot have user PINs or individually deleted RFID keyfobs.ID Lock 101 cannot have Service PIN Mode (Mode on ID-101 is always on).ID Lock 101 cannot be remote configured on volume, hinge direction.ID Lock 101 does not have the ReLock function (Mod on ID-101 is always on).This is a read-only parameter, it cannot be changed.
Size: 1 Byte, Default Value: 96

Setting Description
65 ID Lock 101
96 ID Lock 150

Parameter 8: Updater mode

Updater mode turns on or off possibility to use the ID Lock 150 Updater app.Turns off when unlocking the door.
Size: 1 Byte, Default Value: 0

Setting Description
0 Updater mode off (silent)
1 Updater mode on (silent)
2 Updater mode off (audible)
3 Updater mode on (audible)

Parameter 9: Master PIN mode

Turns on or off Master PIN unlock capability.Master PIN is identifier 109.
Size: 1 Byte, Default Value: 1

Setting Description
0 Master PIN cannot unlock
1 Master PIN unlocks

Technical Data

Hardware Platform ZM5202
Device Type Door Lock - Keypad
Network Operation Listening Sleeping Slave
Firmware Version HW: 1 FW: 1.06:01.71
Z-Wave Version 6.51.06
Certification ID ZC10-19066550
Z-Wave Product Id 0x0373.0x0003.0x0001
Color Dark Green
IP (Ingress Protection) Rated ok
Outdoor Use ok
Supported Notification Types Access ControlEmergency AlarmHome Security
Firmware Updatable Updatable by Consumer by RF
Door Lock Type Deadbolt Motor Attachment
Sensors Air TemperatureOpen/Closed (Binary)RF Signal StrengthVoltage
Frequency XXfrequency
Maximum transmission power XXantenna
Door Lock - Keypad