Quickstart

This is a secure Wall Controller for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
Remove white pushbutton cover and press on the center switch with a non-conductive object. The LEDs will now start blinking on pushbutton 1 (upper left pushbutton)



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

The front is elegantly designed with a diffused backlight in each of the four pushbuttons. The pushbuttons can light up in all colors which can be used to show the status of a lamp, as orientation light during nighttime, visual alarm and much more.Each pushbutton is a tactile switch designed that can hold up to four functions and control either a wired lamp or other Z-Wave devices, e.g. other light dimmers, roller shutters and power outlets.The light dimmer can dim all dimmable light sources from 0-250 W.MATRIX ZDB5100 is designed to fit into all FUGA compatible wall boxes and cover frames.

Reset to factory default Remove white pushbutton cover and long-press the center switch for 10 seconds with a non-conductive object.Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Inclusion Remove white pushbutton cover and press on the center switch with a non-conductive object. The LEDs will now start blinking on pushbutton 1 (upper left pushbutton)
Exclusion Remove white pushbutton cover and press on the center switch with a non-conductive object. The LEDs will now start blinking on pushbutton 1 (upper left pushbutton)
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Lifeline. Sends Device Reset notifications, and Central Scene notifications.
2 5 Sends Basic Report with information about the actual level for the dimmer. This report is used by other MATRIX devices that are used for controlling this dimmer.
3 5 Nodes in this group receive Binary Switch Set commands when pushbuttons 1-4 are operated. It can be used for controlling other Z-Wave devices, e.g. a relay module.
4 5 Nodes in this group receive Multi-Level Switch Set / Multi-Level Switch Start Level Change / Multi-Level Switch Stop Level Change when pushbuttons 1-4 are operated. It can, as an example, be used for controlling light dimmers.

Configuration Parameters

Parameter 1: Operating pushbutton(s) for dimmer

This parameter specifies which pushbutton(s) that shall be used to control the built-in dimmer.The parameter is a bitmask, so each of the values can be added together in order to have several pushbuttons to operate the dimmer.
Size: 1 Byte, Default Value: 1

Setting Description
0 No local operation of the dimmer.
1 Pushbutton 1 controls the dimmer.
2 Pushbutton 2 controls the dimmer.
4 Pushbutton 3 controls the dimmer.
8 Pushbutton 4 controls the dimmer.

Parameter 11: Pushbutton debounce timer

Pushbutton input debounce time in 0.01 seconds resolution.
Size: 1 Byte, Default Value: 5

Setting Description
0 - 255 02.55 seconds. Default is 5, which equals to a debounce-filter on 50 milliseconds (0.05 seconds)

Parameter 12: Pushbutton press threshold time

Specifies the time that a pushbutton must be activated before it is detected as pressed. Resolution is in 0.01 seconds.
Size: 1 Byte, Default Value: 20

Setting Description
0 - 255 02.55 seconds. Default is 20, which equals to 200 milliseconds (0.2 seconds).

Parameter 13: Pushbutton held threshold time

Specifies the time that a pushbutton must have been activated before it is accepted as held-down. Resolution is 0.01 seconds.
Size: 1 Byte, Default Value: 50

Setting Description
0 - 255 02.55 seconds. Default is 50, which equals to 500 milliseconds (0,5 seconds).

Parameter 14: Global brightness control

This parameter specifies a common brightness for each of the three base colours for all four pushbutton indicators.Byte 1: Red brightness. Byte 2: Green brightness. Byte 3: Blue brightness. Byte 4: Not usedmust be set to 0.
Size: 4 Byte, Default Value: 255

Setting Description
0 - 255 Byte 3: Brightness level for the blue colour in the 4 indicator groups. (Default is 255)
0 Byte 4: Not usedmust be set to 0.
0 - 255 Byte1: Brightness level for the red colour in the 4 indicator groups. (Default is 255)
0 - 255 Byte 2: Brightness level for the green colour in the 4 indicator groups. (Default is 255)

Parameter 15: Associations groups, transmission when included secure

This parameter specifies if commands are transmitted as a secure message for each of the association groups.This parameter is only used when the device is included in security mode (either S0 or S2). The values are bitmasks that can be added up to select several options.
Size: 2 Byte, Default Value: 8191

Setting Description
0 All messages in all groups are sent as insecure.
1 Messages in association group 2 is sent as secure.
2 Messages in association group 3 is sent as secure.
4 Messages in association group 4 is sent as secure.
8 Messages in association group 5 is sent as secure.
16 Messages in association group 6 is sent as secure.
32 Messages in association group 7 is sent as secure.
64 Messages in association group 8 is sent as secure.
128 Messages in association group 9 is sent as secure.
256 Messages in association group 10 is sent as secure.
512 Messages in association group 11 is sent as secure.
1024 Messages in association group 12 is sent as secure.
2048 Messages in association group 13 is sent as secure.
4096 Messages in association group 14 is sent as secure.
8191 Messages in all association groups are sent as secure.

Parameter 16: Pushbutton 1 functionality

This parameter specifies the functionality of pushbutton 1.
Size: 1 Byte, Default Value: 0

Setting Description
0 Standard toggle-function, the state is switched between on and off, dimming up and down.
1 Automatic turn off after the time has expired (staircase lighting function), the time is specified in the next configuration parameter.
2 Automatic turn on after the time has expired, the time is specified in the next configuration parameter.
3 Always turn off or dim down . Using this parameter, the pushbutton can only send off or dim down commands. Use this in pair with another pushbutton with value 4 (see chapter 2.6 in the manual)
4 Always turn on or dim up. Using this parameter, the pushbutton can only send on or dim up commands. Use this in pair with another pushbutton with value 3 (see chapter 2.6 in the manual)

Parameter 17: Timer value for pushbutton 1

This parameter specifies the time used in previous configuration parameter. This parameter is only applicable if previous parameter has value 1 or 2.
Size: 2 Byte, Default Value: 300

Setting Description
0 - 43200 Specifies the time in seconds. Default is 300 = 5 minutes.

Parameter 18: Multi-Level Switch Set values for pushbutton 1

Byte 1: Enable / DisableByte 2: Upper switch valueByte 3: Lower switch valueByte 4: Not usedmust be set to 0.
Size: 1 Byte, Default Value: 0

Setting Description
0 Byte 1: DisabledA single activation of the button will not result in commands are sent to devices in association group 4.
0 - 99 Byte 2: When single pressing the button for ON, a Multilevel Switch Set with this value will be send to devices in association group 4.
0 - 99 Byte 3: When single pressing the button for OFF, a Multilevel Switch Set with this value will be send to devices in association group 4. (Default = 0)
0 Byte 4: Not usedmust be set to 0
1 Byte 1: EnabledA single activation will result in commands are sent to devices in association group 4, they will receive commands with the values set below. (Default).
255 Byte 2: When single pressing the button for ON, a Multilevel Switch Set with this value will be send to devices in association group 4. (Default = 255)

Parameter 19: Binary Switch Set support for pushbutton 1

This parameter specifies how received Binary Switch Set commands are handled.
Size: 1 Byte, Default Value: 0

Setting Description
0 Binary Switch Set only controls the pushbutton indicator LEDs, ON/OFF
1 Binary Switch Set controls the internal switch status and the pushbutton indicator LEDs
2 Binary Switch Set is handled as if the user had activated the pushbutton, including transmission of commands via the association groups

Parameter 2: Duration of dimming

This parameter specifies the duration of a full regulation of the light from 0% to 100%. A regulation of the light with 1% will take 1/100 of the specified duration. This is used when a pushbutton is held-down for controlling the dimming, and when the dimming is fulfilled from other Z-Wave devices.
Size: 1 Byte, Default Value: 5

Setting Description
0 Immediately
1 - 127 Duration in seconds.
128 - 255 Duration in minutes (minus 127) from 1128 minutes, where 128 is 1 minute

Parameter 20: Pushbutton 1 LED indication

This parameter specifies how the LED indication is controlled.
Size: 1 Byte, Default Value: 7

Setting Description
0 Internal LED control is disabled, only external commands control the indication
1 The LED indication follows the switch status
2 The LED indication follows the switch statuswith inverted functionality
3 Same as 1
4 Same as 2
5 The LED indication follows the status of the internal dimmer, ON or OFF
6 The LED indication follows the status of the internal dimmer with inverted functionality, ON or OFF
7 The LED indicator is ON for 5 seconds when the pushbutton is activated

Parameter 21: Colour commands for pushbutton 1 LED indication

This parameter specifies how Command Class Switch Color commands are handled.
Size: 1 Byte, Default Value: 1

Setting Description
0 Direct control; the LED indication shows the received colour immediately, until the pushbutton is activated
1 Colour command sets the colour for OFF indication
2 Colour command sets the colour for ON indication

Parameter 22: ON indication RGB-saturation for pushbutton 1

This parameter specifies the saturation levels for the red, green and blue LEDs, when ON status is indicated. (Default is the ON-state indicated by a 50% blue colour).Byte 1: Colour saturation, red.Byte 2: Colour saturation, green.Byte 3: Colour saturation, blue.Byte 4: LED control.
Size: 4 Byte, Default Value: 255

Setting Description
0 - 255 Byte 4: LED indicator control; see the application note about this parameter. (Default is 0)
0 - 255 Byte 1: Specifies the saturation for the red LEDs. (Default is 0)
0 - 255 Byte 2: Specifies the saturation for the green LEDs. (Default is 0)
0 - 255 Byte 3: Specifies the saturation for the blue LEDs. (Default is 127)

Parameter 23: OFF indication RGB-saturation for pushbutton 1

This parameter specifies the saturation levels for the red, green and blue LEDs, when OFF status is indicated. (Default is the OFF-state indicated as a low white light on 5%).Byte 1: Colour saturation, red.Byte 2: Colour saturation, green.Byte 3: Colour saturation, blue.Byte 4: LED control.
Size: 4 Byte, Default Value: 47

Setting Description
0 - 255 Byte 3: Specifies the saturation for the blue LEDs. (Default is 47)
0 - 255 Byte 4: LED indicator control; see the application note about this parameter. (Default is 0)
0 - 255 Byte 1: Specifies the saturation for the red LEDs. (Default is 47)
0 - 255 Byte 2: Specifies the saturation for the green LEDs. (Default is 47)

Parameter 24: Pushbutton 2 functionality

This parameter specifies the functionality of pushbutton 2.
Size: 1 Byte, Default Value: 0

Setting Description
0 Standard toggle-function, the state is switched between on and off, dimming up and down.
1 Automatic turn off after the time has expired (staircase lighting function), the time is specified in the next configuration parameter.
2 Automatic turn on after the time has expired, the time is specified in the next configuration parameter.
3 Always turn off or dim down. Using this parameter, the pushbutton can only send off or dim down commands. Use this in pair with another pushbutton with value 4 (see chapter 2.6 in the manual)
4 Always turn on or dim up. Using this parameter, the pushbutton can only send on or dim up commands. Use this in pair with another pushbutton with value 3 (see chapter 2.6 in the manual)

Parameter 25: Timer value for pushbutton 2

This parameter specifies the time used in previous configuration parameter. This parameter is only applicable if previous parameter has value 1 or 2.
Size: 2 Byte, Default Value: 300

Setting Description
0 Enhanced LED control is disabled
0 - 43200 Specifies the time in seconds. Default is 300 = 5 minutes
1 Enhanced LED control is enabled

Parameter 26: Multi-Level Switch Set values for pushbutton 2

Byte 1: Enable / Disable.Byte 2: Upper switch value.Byte 3: Lower switch value.Byte 4: Not usedmust be set to 0.
Size: 4 Byte, Default Value: 0

Setting Description
0 Byte 1: DisabledA single activation of the pushbutton will not send commands to devices in association group 4
0 Byte 4: Not usedmust be set to 0.
0 - 99 Byte 3: When single pressing the pushbutton for OFF, a Multilevel Switch Set with this value will be send to devices in association group 4. (Default = 0)
0 - 99 Byte 2: When single pressing the pushbutton for ON, a Multilevel Switch Set with this value will be send to devices in association group 4. (Default = 255)
1 Byte 1: EnabledA single activation will send commands to devices in association group 4. Devices will receive commands with the values set in Byte 2 and 3 (Default)
255 Byte 2: When single pressing the pushbutton for ON, a Multilevel Switch Set with this value will be send to devices in association group 4. (Default = 255)

Parameter 27: Binary Switch Set support for pushbutton 2

This parameter specifies how received Binary Switch Set commands are handled.
Size: 1 Byte, Default Value: 0

Setting Description
0 Binary Switch Set only controls the button indicator LEDs, ON/OFF
1 Binary Switch Set controls the internal switch status and the button indicator LEDs
2 Binary Switch Set is handled as if the user had activated the button, including transmission of commands via the association groups

Parameter 28: Pushbutton 2 LED indication

This parameter specifies how the LED indication is controlled.
Size: 1 Byte, Default Value: 7

Setting Description
0 Internal LED control is disabled, only external commands control the indication
1 The LED indication follows the switch status
2 The LED indication follows the switch statuswith inverted functionality
3 Same as 1
4 Same as 2
5 The LED indication follows the status of the internal dimmer, ON or OFF
6 The LED indication follows the status of the internal dimmer with inverted functionality, ON or OFF
7 The LED indicator is ON for 5 seconds when the pushbutton is activated

Parameter 29: Colour commands for pushbutton 2 LED indication

This parameter specifies how Command Class Switch Color commands is handled.
Size: 1 Byte, Default Value: 1

Setting Description
0 Direct control; the LED indication shows the received colour immediately, until the pushbutton is activated
1 Colour command sets the colour for OFF indication
2 Colour command sets the colour for ON indication

Parameter 3: Duration of on/off

This parameter specifies the duration when turning the light on or off.
Size: 1 Byte, Default Value: 0

Setting Description
0 Immediately
1 - 127 Time in seconds
128 - 255 Time in minutes (minus 127) from 1128 minutes, where 128 is 1 minute

Parameter 30: ON indication RGB-saturation for pushbutton 2

This parameter specifies the saturation levels for the red, green and blue LEDs, when ON status is indicated. (Default is the ON-state indicated by a 50% blue colour).Byte 1: Colour saturation, red.Byte 2: Colour saturation, green.Byte 3: Colour saturation, blue.Byte 4: LED control.
Size: 4 Byte, Default Value: 0

Setting Description
0 - 255 Byte 1:Specifies the saturation for the red LEDs. (Default is 0)
0 - 255 Byte 2: Specifies the saturation for the green LEDs. (Default is 0)
0 - 255 Byte 3: Specifies the saturation for the blue LEDs. (Default is 127)
0 - 255 Byte 4: LED indicator control; see the application note about this parameter. (Default is 0)

Parameter 31: OFF indication RGB-saturation for pushbutton 2

This parameter specifies the saturation levels for the red, green and blue LEDs, when OFF status is indicated. (Default is the OFF-state indicated as a low white light on 5%).Byte 1: Colour saturation, red.Byte 2: Colour saturation, green.Byte 3: Colour saturation, blue.Byte 4: LED control.
Size: 4 Byte, Default Value: 255

Setting Description
0 - 255 Byte 4: LED indicator control; see the application note about this parameter (Default is 0)
0 - 255 Byte 2: Specifies the saturation for the green LEDs (Default is 47)
0 - 255 Byte 3: Specifies the saturation for the blue LEDs (Default is 47)
0 - 255 Byte 1: Specifies the saturation for the red LEDs (Default is 47)

Parameter 32: Pushbutton 3 functionality

This parameter specifies the functionality of pushbutton 3.
Size: 1 Byte, Default Value: 0

Setting Description
0 Standard toggle-function, the state is switched between on and off, dimming up and down
1 Automatic turn off after the time has expired (staircase lighting function), the time is specified in the next configuration parameter.
2 Automatic turn on after the time has expired, the time is specified in the next configuration parameter.
3 Always turn off or dim down. Using this parameter, the pushbutton can only send off or dim down commands. Use this in pair with another pushbutton with value 4 (see chapter 2.6 in the manual)
4 Always turn on or dim up. Using this parameter, the pushbutton can only send on or dim up commands. Use this in pair with another pushbutton with value 3 (see chapter 2.6 in the manual)

Parameter 33: Timer value for pushbutton 3

This parameter specifies the time used in previous configuration parameter. This parameter is only applicable if previous parameter has value 1 or 2.
Size: 2 Byte, Default Value: 300

Setting Description
0 - 43200 Specifies the time in seconds. Default is 300 = 5 minutes

Parameter 34: Multi-Level Switch Set values for pushbutton 3

Byte 1: Enable / Disable.Byte 2: Upper switch value.Byte 3: Lower switch value.Byte 4: Not usedmust be set to 0.
Size: 4 Byte, Default Value: 0

Setting Description
0 Byte 4: Not usedmust be set to 0
0 - 99 Byte 3: When single pressing the pushbutton for OFF, a Multilevel Switch Set with this value will be send to devices in association group 4 (Default = 0)
0 Byte 1: DisabledA single activation of the pushbutton will not send commands to devices in association group 4
0 - 99 Byte 2: When single pressing the pushbutton for ON, a Multilevel Switch Set with this value will be send to devices in association group 4
1 Byte 1: EnabledA single activation will send commands to devices in association group 4. Devices will receive commands with the values set in Byte 2 and 3 (default)
255 Byte 2: When single pressing the pushbutton for ON, a Multilevel Switch Set with this value will be send to devices in association group 4 (default)

Parameter 35: Binary Switch Set support for pushbutton 3

This parameter specifies how received Binary Switch Set commands are handled.
Size: 1 Byte, Default Value: 0

Setting Description
0 Binary Switch Set only controls the pushbutton indicator LEDs, ON/OFF
1 Binary Switch Set controls the internal switch status and the pushbutton indicator LEDs
2 Binary Switch Set is handled as if the user had activated the pushbutton, including transmission of commands via the association groups

Parameter 36: Pushbutton 3 LED indication

This parameter specifies how the LED indication is controlled.
Size: 1 Byte, Default Value: 7

Setting Description
0 Internal LED control is disabled, only external commands control the indication
1 The LED indication follows the switch status
2 The LED indication follows the switch statuswith inverted functionality
3 Same as 1
4 Same as 2
5 The LED indication follows the status of the internal dimmer, ON or OFF
6 The LED indication follows the status of the internal dimmer with inverted functionality, ON or OFF
7 The LED indicator is ON for 5 seconds when the pushbutton is activated

Parameter 37: Colour commands for pushbutton 3 LED indication

This parameter specifies how Command Class Switch Color commands is handled
Size: 1 Byte, Default Value: 1

Setting Description
0 Direct control; the LED indication shows the received colour immediately, until the pushbutton is activated
1 Colour command sets the colour for OFF indication
2 Colour command sets the colour for ON indication

Parameter 38: ON indication RGB-saturation for pushbutton 3

This parameter specifies the saturation levels for the red, green and blue LEDs, when ON status is indicated. (Default is the ON-state indicated by a 50% blue colour).Byte 1: Colour saturation, red.Byte 2: Colour saturation, green.Byte 3: Colour saturation, blue.Byte 4: LED control.
Size: 4 Byte, Default Value: 127

Setting Description
0 - 255 Byte 1: Specifies the saturation for the red LEDs. (Default is 0)
0 - 255 Byte 3: Specifies the saturation for the blue LEDs. (Default is 127)
0 - 255 Byte 2: Specifies the saturation for the green LEDs. (Default is 0)
0 - 255 Byte 4: LED indicator control; see the application note about this parameter. (Default is 0)

Parameter 39: OFF indication RGB-saturation for pushbutton 3

This parameter specifies the saturation levels for the red, green and blue LEDs, when OFF status is indicated. (Default is the OFF-state indicated as a low white light on 5%).Byte 1: Colour saturation, red.Byte 2: Colour saturation, green.Byte 3: Colour saturation, blue.Byte 4: LED control.
Size: 4 Byte, Default Value: 47

Setting Description
0 - 255 Byte 2: Specifies the saturation for the green LEDs. (Default is 47)
0 - 255 Byte 3: Specifies the saturation for the blue LEDs. (Default is 47)
0 - 255 Byte 4: LED indicator control; see the application note about this parameter. (Default is 0)
0 - 255 Byte 1: Specifies the saturation for the red LEDs. (Default is 47).

Parameter 4: Dimmer mode

The dimmer can work in three different modes: on/off, leading edge or trailing edge.
Size: 1 Byte, Default Value: 1

Setting Description
0 No dimming, only on/off (0/100%).
1 Trailing edge dimming
2 Leading edge dimming

Parameter 40: Pushbutton 4 functionality

This parameter specifies the functionality of pushbutton 4.
Size: 1 Byte, Default Value: 0

Setting Description
0 Standard toggle-function, the state is switched between on and off, dimming up and down
1 Automatic turn off after the time has expired (staircase lighting function), the time is specified in the next configuration parameter.
2 Automatic turn on after the time has expired, the time is specified in the next configuration parameter.
3 Always turn off or dim down. Using this parameter, the pushbutton can only send off or dim down commands. Use this in pair with another pushbutton with value 4 (see chapter 2.6 in the manual).
4 Always turn on or dim up. Using this parameter, the pushbutton can only send on or dim up commands. Use this in pair with another pushbutton with value 3 (see chapter 2.6 in the manual).

Parameter 41: Timer value for pushbutton 4

This parameter specifies the time used in previous configuration parameter. This parameter is only applicable if previous parameter has value 1 or 2.
Size: 2 Byte, Default Value: 300

Setting Description
0 - 43200 Specifies the time in seconds. Default is 300 = 5 minutes

Parameter 42: Multi-Level Switch Set values for pushbutton 4

Byte 1: Enable / Disable.Byte 2: Upper switch value.Byte 3: Lower switch value.Byte 4: Not usedmust be set to 0.
Size: 4 Byte, Default Value: 255

Setting Description
0 Byte 4: Not usedmust be set to 0.
0 - 99 Byte 2: When single pressing the pushbutton for ON, a Multilevel Switch Set with this value will be send to devices in association group 4
0 Byte 1: DisabledA single activation of the pushbutton will not send commands to devices in association group 4.
0 - 99 Byte 3: When single pressing the pushbutton for OFF, a Multilevel Switch Set with this value will be send to devices in association group 4. (Default = 0)
1 Byte 1: EnabledA single activation will send commands to devices in association group 4. Devices will receive commands with the values set in Byte 2 and 3 (Default).
255 Byte 2: When single pressing the pushbutton for ON, a Multilevel Switch Set with this value will be send to devices in association group 4. (Default)

Parameter 43: Binary Switch Set support for pushbutton 4

This parameter specifies how received Binary Switch Set commands are handled.
Size: 1 Byte, Default Value: 2

Setting Description
0 Binary Switch Set only controls the pushbutton indicator LEDs, ON/OFF
1 Binary Switch Set controls the internal switch status and the pushbutton indicator LEDs
2 Binary Switch Set is handled as if the user had activated the pushbutton, including transmission of commands via the association groups

Parameter 44: Pushbutton 4 LED indication

This parameter specifies how the LED indication is controlled.
Size: 1 Byte, Default Value: 7

Setting Description
0 Internal LED control is disabled, only external commands control the indication.
1 The LED indication follows the switch status
2 The LED indication follows the switch statuswith inverted functionality
3 Same as 1
4 Same as 2
5 The LED indication follows the status of the internal dimmer, ON or OFF
6 The LED indication follows the status of the internal dimmer with inverted functionality, ON or OFF
7 The LED indicator is ON for 5 seconds when the pushbutton is activated

Parameter 45: Colour commands for pushbutton 4 LED indication

This parameter specifies how Command Class Switch Color commands are handled.
Size: 1 Byte, Default Value: 1

Setting Description
0 Direct control; the LED indication shows the received colour immediately, until the pushbutton is activated
1 Colour command sets the colour for OFF indication
2 Colour command sets the colour for ON indication

Parameter 46: ON indication RGB-saturation for pushbutton 4

This parameter specifies the saturation levels for the red, green and blue LEDs, when ON status is indicated. (Default is the ON-state indicated by a 50% blue colour).Byte 1: Colour saturation, red.Byte 2: Colour saturation, green.Byte 3: Colour saturation, blue.Byte 4: LED control.
Size: 4 Byte, Default Value: 255

Setting Description
0 - 255 Byte 1: Specifies the saturation for the red LEDs. (Default is 0)
0 - 255 Byte 2: Specifies the saturation for the green LEDs. (Default is 0)
0 - 255 Byte 3: Specifies the saturation for the blue LEDs. (Default is 127)
0 - 255 Byte 4: LED indicator control; see the application note about this parameter. (Default is 0)

Parameter 47: OFF indication RGB-saturation for pushbutton 4

This parameter specifies the saturation levels for the red, green and blue LEDs, when OFF status is indicated. (Default is the OFF-state indicated as a low white light on 5%).Byte 1: Colour saturation, red.Byte 2: Colour saturation, green.Byte 3: Colour saturation, blue.Byte 4: LED control.
Size: 4 Byte, Default Value: 255

Setting Description
0 - 255 Byte 1: Specifies the saturation for the red LEDs. (Default is 47)
0 - 255 Byte 2: Specifies the saturation for the green LEDs. (Default is 47)
0 - 255 Byte 4: LED indicator control; see the application note about this parameter. (Default is 0)
0 - 255 Byte 3: Specifies the saturation for the blue LEDs. (Default is 47)

Parameter 5: Dimmer minimum level

This parameter specifies the actual level of the dimmer output when set to 0%.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 99 Corresponds to 099%

Parameter 6: Dimmer maximum level

This parameter specifies the actual level of the dimmer output when set to 99%.
Size: 1 Byte, Default Value: 99

Setting Description
0 - 99 Corresponds to 099%

Parameter 7: Central Scene notifications

This parameter can be used for disabling Central Scene notifications.
Size: 1 Byte, Default Value: 1

Setting Description
0 Notifications are disabled
1 Notifications are enabled

Parameter 8: Double-activation functionality

This parameter specifies the reaction when double-activating the pushbuttons.
Size: 1 Byte, Default Value: 1

Setting Description
0 Double-activation disabled
1 Double-activation sets light to 100%

Parameter 9: Triple-activation of pushbutton 1

This parameter can be used for disabling the Z-Wave network add/remove process when triple-activating pushbutton 1. If disabled, the triple-activation functionality can be used as a Central Scene notification.
Size: 1 Byte, Default Value: 1

Setting Description
0 Triple-activation of pushbutton 1, does not start the add/remove process.
1 Triple-activation of pushbutton 1, starts the add/remove process

Technical Data

Hardware Platform ZM5101
Device Type Wall Controller
Network Operation Always On Slave
Firmware Version HW: 2 FW: 1.01
Z-Wave Version 6.71.03
Certification ID ZC10-19066525
Z-Wave Product Id 0x0234.0x0003.0x0121
Neutral Wire Required ok
IP (Ingress Protection) Rated ok
Firmware Updatable
Color
Electric Load Type
Switch Type
Z-Wave Scene Type
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)Wall Controller