Quickstart

This is a secure On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
Inclusion (Add)To include (Add) the device to a Z-Wave network, press the button four times in quick succession. When the device is in Add mode, the LED flashes green. When finished, the new status is:Add:The LED lights up briefly in greenRemove:The LED lights up briefly in red



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

The myTEM Radio Socket is a universal, Z-Wave compatible switch/adapter for loads up to 2300 watts (type J, CH). The power and energy consumption of the connected device is measured. In addition, a temperature and humidity sensor is integrated. These values are reported to the central controller and can be used to control other functions.

Reset to factory default Remark: It is recommended to use the primary controller of the previous network unless it is no longer available or damaged.To start the Remove process press the button four times in quick succession. The LED flashes red and then the new status is:Add: The LED lights up briefly in greenRemove: The LED lights up briefly in red
Inclusion Inclusion (Add)To include (Add) the device to a Z-Wave network, press the button four times in quick succession. When the device is in Add mode, the LED flashes green. When finished, the new status is:Add:The LED lights up briefly in greenRemove:The LED lights up briefly in red
Exclusion Exclusion (Remove)To exclude (Remove) the device from a Z-Wave network, press the button four times in quick succession. When the device is in Add mode, the LED flashes green. When finished, the new status is:Add:The LED lights up briefly in greenRemove:The LED lights up briefly in red
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plus Lifeline a) Notification Report: System, Heartbeat b) Notification Report: Power Management Power has been applied c) Meter Report: Single electric meter, Kilowatt d) Meter Report: Single electric meter,Kilowatt hours e) Multilevel Sensor Report: Air temperature, Celsius f) Multilevel Sensor Report: Humidity, Percentage value g) Binary Switch ReportFurther information and how to trigger the events are under Description in the manual

Configuration Parameters

Parameter 1: Heartbeat Rate

If the Notification System Heartbeat is on, a Notification Report System Heartbeat is sent periodically every 60 minutes (default value).
Size: 2 Byte, Default Value: 60

Setting Description
1 - 1440 Heartbeat rate [min]

Parameter 10: Send Interval Humidity

If the humidity value does not change, the Multilevel Sensor Report with the actual humidity is sent after the Send Interval Humidity.
Size: 2 Byte, Default Value: 5

Setting Description
1 - 120 Send interval humidity [min]

Parameter 11: Minimum Delta Humidity Send

Whenever the measured humidity has changed by the Minimum Delta Humidity Send value since the last value sent, the actual humidity is sent by a Multilevel Sensor Report.
Size: 2 Byte, Default Value: 10

Setting Description
10 - 1000 Minimum delta humidity [0.1 %]

Parameter 2: Main Voltage

The Main Voltage is used - together with the Phase Shift parameter and the messured current - to calculate the actual power of the output and the cumulated energy.
Size: 2 Byte, Default Value: 230

Setting Description
80 - 280 Main voltage [V]

Parameter 3: Phase Shift - Cosines (Phi)

The Phase Shift is used - together with the Main Voltage parameter and the messured current - to calculate the actual power of the output and the cumulated energy.
Size: 2 Byte, Default Value: 100

Setting Description
0 - 100 Phase shift [0.01%]

Parameter 4: Send Interval Power

If the power value of the output does not change, the Meter Report for the actual power is sent after the Send Interval Power.
Size: 2 Byte, Default Value: 5

Setting Description
1 - 120 Send interval power [min]

Parameter 5: Minimum Delta Power Send

Whenever the calculated power has changed by the Minimum Delta Power Send value since the last value sent, the actual power is sent by a Meter Report.
Size: 2 Byte, Default Value: 5

Setting Description
1 - 100 Minimum delta power [%]

Parameter 7: Minimum delta energy send

Whenever the cumulated energy has changed by the Minimum Delta Energy send value since the last value sent, the cumulated energy is sent by a Meter Report.
Size: 2 Byte, Default Value: 2000

Setting Description
1 - 50000 Minimum delta energy [0.001 kWh]

Parameter 8: Send Interval Temperature

If the temperature value does not change, the Multilevel Sensor Report with the actual temperature is sent after the Send Interval Temperature
Size: 2 Byte, Default Value: 5

Setting Description
1 - 120 Send interval energy [min]
1 - 120 Send interval temperature [min]

Parameter 9: Minimum Delta Temperature Send

Whenever the measured temperature has changed by the Minimum Delta Temperature Send value since the last value sent, the actual temperature is sent by Multilevel Sensor Report.
Size: 2 Byte, Default Value: 5

Setting Description
1 - 100 Minimum delta temperature [0.1 K]

Technical Data

Hardware Platform ZM5101
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.00
Z-Wave Version 6.71.03
Certification ID ZC10-19056523
Z-Wave Product Id 0x034E.0x0001.0x0004
Supported Meter Type Electric Energy
Electric Load Type ELV (Electronic)IncandescentInductive (e.g. Motor)
Sensors Air TemperatureHumidity
Supported Notification Types Power ManagementSystem
Firmware Updatable Updatable by Consumer by RF
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)On/Off Power Switch