Inclusion (Add)To include (Add) the device to a Z-Wave network, press the button four times in quick succession. When the device is in Add mode, the LED flashes green. When finished, the new status is:Add:The LED lights up briefly in greenRemove:The LED lights up briefly in red
The myTEM Radio Socket is a universal, Z-Wave compatible switch/adapter for loads up to 2300 watts (type J, CH). The power and energy consumption of the connected device is measured. In addition, a temperature and humidity sensor is integrated. These values are reported to the central controller and can be used to control other functions.
Reset to factory default | Remark: It is recommended to use the primary controller of the previous network unless it is no longer available or damaged.To start the Remove process press the button four times in quick succession. The LED flashes red and then the new status is:Add: The LED lights up briefly in greenRemove: The LED lights up briefly in red |
Inclusion | Inclusion (Add)To include (Add) the device to a Z-Wave network, press the button four times in quick succession. When the device is in Add mode, the LED flashes green. When finished, the new status is:Add:The LED lights up briefly in greenRemove:The LED lights up briefly in red |
Exclusion | Exclusion (Remove)To exclude (Remove) the device from a Z-Wave network, press the button four times in quick succession. When the device is in Add mode, the LED flashes green. When finished, the new status is:Add:The LED lights up briefly in greenRemove:The LED lights up briefly in red |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline a) Notification Report: System, Heartbeat b) Notification Report: Power Management Power has been applied c) Meter Report: Single electric meter, Kilowatt d) Meter Report: Single electric meter,Kilowatt hours e) Multilevel Sensor Report: Air temperature, Celsius f) Multilevel Sensor Report: Humidity, Percentage value g) Binary Switch ReportFurther information and how to trigger the events are under Description in the manual |
If the Notification System Heartbeat is on, a Notification Report System Heartbeat is sent periodically every 60 minutes (default value). Size: 2 Byte, Default Value: 60
Setting | Description |
---|---|
1 - 1440 | Heartbeat rate [min] |
If the humidity value does not change, the Multilevel Sensor Report with the actual humidity is sent after the Send Interval Humidity. Size: 2 Byte, Default Value: 5
Setting | Description |
---|---|
1 - 120 | Send interval humidity [min] |
Whenever the measured humidity has changed by the Minimum Delta Humidity Send value since the last value sent, the actual humidity is sent by a Multilevel Sensor Report. Size: 2 Byte, Default Value: 10
Setting | Description |
---|---|
10 - 1000 | Minimum delta humidity [0.1 %] |
The Main Voltage is used - together with the Phase Shift parameter and the messured current - to calculate the actual power of the output and the cumulated energy. Size: 2 Byte, Default Value: 230
Setting | Description |
---|---|
80 - 280 | Main voltage [V] |
The Phase Shift is used - together with the Main Voltage parameter and the messured current - to calculate the actual power of the output and the cumulated energy. Size: 2 Byte, Default Value: 100
Setting | Description |
---|---|
0 - 100 | Phase shift [0.01%] |
If the power value of the output does not change, the Meter Report for the actual power is sent after the Send Interval Power. Size: 2 Byte, Default Value: 5
Setting | Description |
---|---|
1 - 120 | Send interval power [min] |
Whenever the calculated power has changed by the Minimum Delta Power Send value since the last value sent, the actual power is sent by a Meter Report. Size: 2 Byte, Default Value: 5
Setting | Description |
---|---|
1 - 100 | Minimum delta power [%] |
Whenever the cumulated energy has changed by the Minimum Delta Energy send value since the last value sent, the cumulated energy is sent by a Meter Report. Size: 2 Byte, Default Value: 2000
Setting | Description |
---|---|
1 - 50000 | Minimum delta energy [0.001 kWh] |
If the temperature value does not change, the Multilevel Sensor Report with the actual temperature is sent after the Send Interval Temperature Size: 2 Byte, Default Value: 5
Setting | Description |
---|---|
1 - 120 | Send interval energy [min] |
1 - 120 | Send interval temperature [min] |
Whenever the measured temperature has changed by the Minimum Delta Temperature Send value since the last value sent, the actual temperature is sent by Multilevel Sensor Report. Size: 2 Byte, Default Value: 5
Setting | Description |
---|---|
1 - 100 | Minimum delta temperature [0.1 K] |
Hardware Platform | ZM5101 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.00 |
Z-Wave Version | 6.71.03 |
Certification ID | ZC10-19056523 |
Z-Wave Product Id | 0x034E.0x0001.0x0004 |
Supported Meter Type | Electric Energy |
Electric Load Type | ELV (Electronic)IncandescentInductive (e.g. Motor) |
Sensors | Air TemperatureHumidity |
Supported Notification Types | Power ManagementSystem |
Firmware Updatable | Updatable by Consumer by RF |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |