Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. To add this device to your network execute the following action:
1) Open the cover.2) Place the device within the direct range of your Z-Wave controller.3) Set the main controller in add mode (see the controllers manual).4) Click the Z-button once or triple click the Z-button quickly, the LED indicator should blink fast. 5) Wait for the adding process to end.6) Successful adding will be confirmed by the Z-Wave controllers message.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

RE.GUARD Water Sensor is a wireless sensor powered by ER14250battery. It is used for detecting water overflowing. It can communicatewith an associated Z-Wave device, such as RE.GUARD Water Control,Siren, Smart Switch, etc.The features list:1) Z-Wave Plus certified for wide compatibility (500 serials product).2) Supports security 0 and security 2 protected mode with AES-128 encryption.3) Contains an extension water detecting probe.4) Temperature measurement.5) The battery life is up to 1 year.6) Support low battery alarm function.7) Support firmware OTA.

Reset to factory default 1)Power on the device2) Press and hold the Z button for more than 20 seconds3)If holding time more than 20 seconds, the LED indicator will keep on for 2 seconds, which means resetting is complete.The reset feature works only when the device has been included into a Z-Wave network.Use this procedure only in the event that the network primary controller is missing or otherwise inoperable.
Inclusion 1) Open the cover.2) Place the device within the direct range of your Z-Wave controller.3) Set the main controller in add mode (see the controllers manual).4) Click the Z-button once or triple click the Z-button quickly, the LED indicator should blink fast. 5) Wait for the adding process to end.6) Successful adding will be confirmed by the Z-Wave controllers message.
Exclusion ) Open the cover.2) Place the device within the direct range of your Z-Wave controller.3) Set the main controller remove mode (see the controllers manual).4) Triple click the Z-button quickly, the LED indicator should blink fast.5) Wait for the removing process to end.6) Successful adding will be confirmed by the Z-Wave controllers message.
NIF XXXNIF
Wakeup Press and hold the Z button for more than 3 seconds and release.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plus Lifeline: 1. Notification Report. Sensor will send Notification Report to the associated nodes 2. Battery Report. Sensor will send Battery Report when the battery level is low and the battery reports value is 0xFF. 3. Device Reset Locally Notification. Sensor will send Device Reset Locally Notification when reset 4.Sensor multilevel report When associated to Group 1, you can adjust the temperature reporting cycle according to the configuration settings.
2 5 1. Basic Set. Water Sensor will send Basic Set to associated nodes when Water leak detected.

Configuration Parameters

Parameter 14: Enable/Disable BASIC SET command

Water Sensor can send BASIC SET command to nodes associated with group 2.
Size: 1 Byte, Default Value: 0

Setting Description
0 Disable
1 Enable

Parameter 15: Value of the BASIC SET

Water sensor can reverse its value of BASIC SET when flooding is triggered.
Size: 1 Byte, Default Value: 0

Setting Description
0 Send BASIC SET VALUE = 255 to nodes associated with group 2 when flooding alarm is triggered. Send BASIC SET VALUE = 0 to nodes associated with group 2 when flooding alarm is canceled.
1 Send BASIC SET VALUE = 0 to nodes associated with group 2 when flooding alarm is triggered. Send BASIC SET VALUE = 255 to nodes associated with group 2 when flooding alarm is canceled.

Parameter 17: Set resend flooding alarm interval (minute)

How much time interval is reported by flooding alarm.
Size: 1 Byte, Default Value: 5

Setting Description
1 - 240 The higher the value, the long the report periodically - in decimal values from 1 to 240

Parameter 19: Temperature report tme (10 minutes)

The sensor measures the temperature every ten minutes, change of 1 degree Celsius will be reported. By default, it must report at least once a day.
Size: 1 Byte, Default Value: 144

Setting Description
3 - 240 the higher the value ,the long the report time

Parameter 20: Set the high temperature alarm trigger value

The accuracy is 0.1 degrees, the United States uses Fahrenheit, and the Fahrenheit temperature range is -670~2570, which is -67.0~257.0F. Other countries use Celsius temperature, Celsius temperature range -550~1250, which is -55.0~125.0 C.
Size: 2 Byte, Default Value: 400

Setting Description
-670 - 2570 the larger the value , the higher the high temperature(US)
-550 - 1250 the larger the value , the higher the high temperature(other)

Parameter 22: Set the low temperature alarm trigger value

The accuracy is 0.1 degrees, the United States uses Fahrenheit, and the Fahrenheit temperature range is -670~2570, which is -67.0~257.0F. Other countries use Celsius temperature, Celsius temperature range -550~1250, which is -55.0~125.0 C.
Size: 2 Byte, Default Value: 0

Setting Description
-670 - 2570 the smaller the value , the lower the low temperature(US)
-550 - 1250 the smaller the value , the lower the low temperature(other)

Parameter 24: Enable/Disable blinking LED when alarm being triggered

Whether the light flashes when the alarm occurs. when the value is 0, the product will not alarm when being triggered; when the value is 1, the product will alarm when being triggered
Size: 1 Byte, Default Value: 1

Setting Description
0 Disable
1 Enable

Parameter 32: Level of low battery

The low voltage alarm threshold corresponds to the amount of power, the unit is the percentage of power, the value range is 10~50, other values are invalid, that is, the power corresponding to the low voltage can be configured to be 10% to 50%.
Size: 1 Byte, Default Value: 20

Setting Description
10 - 50 Set the trigger value for the low battery alarm

Technical Data

Hardware Platform ZM5202
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 1 FW: 1.03
Z-Wave Version 6.71.01
Certification ID ZC10-19056475
Z-Wave Product Id 0x0413.0x021a.0x0002
Firmware Updatable Updatable by Consumer by RF
Color White
Supported Notification Types Heat AlarmHome SecurityWater Alarm
Sensors Air Temperature
Frequency Russia - 868.4MHz, 869.85MHz
Maximum transmission power 5 mW
RussiaNotification Sensor