This is a
Inclusion (Add)To include (Add) the device to a Z-Wave network, press the button four times in quick succession. When the device is in Add mode, the LED flashes green. When finished, the new status is:Add:The LED lights up briefly in greenRemove:The LED lights up briefly in red
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
The myTEM Radio Socket is a universal, Z-Wave compatible switch/adapter for loads up to 3'600 watts (type F, EU). The power and energy consumption of the connected device is measured. In addition, a temperature and humidity sensor is integrated. These values are reported to the central controller and can be used to control other functions.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
Remark: It is recommended to use the primary controller of the previous network unless it is no longer available or damaged.To start the Remove process press the button four times in quick succession. The LED flashes red and then the new status is:Add: The LED lights up briefly in greenRemove: The LED lights up briefly in red
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline a) Notification Report: System, Heartbeat b) Notification Report: Power Management Power has been applied c) Meter Report: Single electric meter, Kilowatt d) Meter Report: Single electric meter,Kilowatt hours e) Multilevel Sensor Report: Air temperature, Celsius f) Multilevel Sensor Report: Humidity, Percentage value g) Binary Switch ReportFurther information and how to trigger the events are under Description in the manual |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
If the Notification System Heartbeat is on, a Notification Report System Heartbeat is sent periodically every 60 minutes (default value). Size: 2 Byte, Default Value: 60
Setting | Description |
---|---|
1 - 1440 | Heartbeat rate [min] |
If the humidity value does not change, the Multilevel Sensor Report with the actual humidity is sent after the Send Interval Humidity. Size: 2 Byte, Default Value: 5
Setting | Description |
---|---|
1 - 120 | Send interval humidity [min] |
Whenever the measured humidity has changed by the Minimum Delta Humidity Send value since the last value sent, the actual humidity is sent by a Multilevel Sensor Report. Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
10 - 1000 | Minimum delta humidity [0.1 %] |
The Main Voltage is used - together with the Phase Shift parameter and the messured current - to calculate the actual power of the output and the cumulated energy. Size: 2 Byte, Default Value: 230
Setting | Description |
---|---|
80 - 280 | Main voltage [V] |
The Phase Shift is used - together with the Main Voltage parameter and the messured current - to calculate the actual power of the output and the cumulated energy. Size: 2 Byte, Default Value: 100
Setting | Description |
---|---|
0 - 100 | Phase shift [0.01%] |
If the power value of the output does not change, the Meter Report for the actual power is sent after the Send Interval Power. Size: 2 Byte, Default Value: 5
Setting | Description |
---|---|
1 - 120 | Send interval power [min] |
Whenever the calculated power has changed by the Minimum Delta Power Send value since the last value sent, the actual power is sent by a Meter Report. Size: 2 Byte, Default Value: 5
Setting | Description |
---|---|
1 - 100 | Minimum delta power [%] |
If the cumulated energy value does not change, the Meter Report for the cumulated energy is sent after the Send Interval Energy. Size: 2 Byte, Default Value: 5
Setting | Description |
---|---|
1 - 120 | Send interval energy [min] |
Whenever the cumulated energy has changed by the Minimum Delta Energy send value since the last value sent, the cumulated energy is sent by a Meter Report. Size: 2 Byte, Default Value: 2000
Setting | Description |
---|---|
1 - 50000 | Minimum delta energy [0.001 kWh] |
If the temperature value does not change, the Multilevel Sensor Report with the actual temperature is sent after the Send Interval Temperature Size: 2 Byte, Default Value: 5
Setting | Description |
---|---|
1 - 120 | Send interval temperature [min] |
Whenever the measured temperature has changed by the Minimum Delta Temperature Send value since the last value sent, the actual temperature is sent by Multilevel Sensor Report. Size: 2 Byte, Default Value: 5
Setting | Description |
---|---|
1 - 100 | Minimum delta temperature [0.1 K] |
Hardware Platform | ZM5101 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.00 |
Z-Wave Version | 6.71.03 |
Certification ID | ZC10-19056472 |
Z-Wave Product Id | 0x034E.0x0001.0x0004 |
Firmware Updatable | Updatable by Consumer by RF |
Electric Load Type | ELV (Electronic)IncandescentInductive (e.g. Motor) |
Sensors | Air TemperatureHumidity |
Supported Notification Types | Power ManagementSystem |
Supported Meter Type | Electric Energy |
Security V2 | S2_UNAUTHENTICATED ,S2_AUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |