This is a
Triple clicks on the integrated button
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Smart Plug is able to detect overvoltage and/or overcurrent cases and through a multicolor LED can send alerts. Furthermore, it protects appliances from eventual overload. A very innovative design, which integrates a complex system that allows a precise energy consumption monitoring. The integration of these features in its very small size product, make it unique on the market.Alerts and visual feedback with RGB LEDAn RGB LED on the device provides visual feedback for overvoltage and / or overcurrent and overpower detection.Small size and innovative designThe WiDom Smart Plug has an elegant design and small size that allows a perfect integration in any home environment.Monitoring of energy consumptionWithin the WiDom Smart Plug is integrated a very precise energy consumption meter that allows you to monitor the consumption of the connected equipment.Simplified device inclusion and exclusionWiDom Smart Plug can be included in any Z-Wave network and work with Z-Wave devices from any other company. WiDom Smart Plug, used as a constantly powered node, will act as a signal repeater to increase network reliability. WiDom Smart Plug is compatible with all Z-Wave certified controllers.Associations and MulticlickWiDom Smart Plug can control, through association, other devices of the Z-Wave network in which is included, when an event of overcurrent, overvoltage or events on the Push Button occur. It is possible to activate a multiclick recognition, for example, you can check with a single click the load connected to the Smart Plug and double-click the associated devices.Zero crossing - Contact protection technologyTo reduce the electrical stress on the relay contacts and ensure a longer life, the open / closed switching of the device always occur when the instantaneous value of voltage is 0.S2 SecurityThe Smart Roller Shutter uses a strong and secure S2 protection system, which provides advanced security features and eliminates the risk of hacking of devices.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 8 | Z-Wave Plus Lifeline |
2 | 8 | Nodes belonging to this groups will be controlled by a basic set if over current event occur; |
3 | 8 | Nodes belonging to this groups will be controlled by a basic set if over voltage event occur; |
4 | 8 | Nodes belonging to this groups will be controlled by a basic set if the button receive one click |
5 | 8 | Nodes belonging to this groups will be controlled by a basic set if the button receive two clicks |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Defines which sequences of click control the local load. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 | 1 click turn ON/OFF the local load |
2 | 2 clicks turn ON/OFF the local load |
3 | 1 click or 2 clicks turn ON/OFF the local load |
Define how to reset the over-current alarm and breaks off the red blinking. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Manual when the relay change its state through the Push Button |
1 | When the over-voltage event is terminated |
Define how to control the devices associated to the overcurrent alarm. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | The associated devices are switched OFF |
-1 | The associated devices are switched ON |
1 - 99 | The associated devices (dimmer, roller shutters) are set to the indicated level |
Defines how to control the devices associated to 1 click event. Size: 1 Byte, Default Value: 100
Setting | Description |
---|---|
0 | The associated devices are switched OFF |
-1 | The associated devices are switched ON |
1 - 99 | The associated devices (dimmer, roller shutters) are set to the indicated level |
100 | If the relay is ON/OFF, the associated devices are ON/OFF |
Defines how to control the devices associated to 2 clicks event. Size: 1 Byte, Default Value: 100
Setting | Description |
---|---|
0 | The associated devices are switched OFF |
-1 | The associated devices are switched ON |
1 - 99 | The associated devices (dimmer, roller shutters) are set to the indicated level |
100 | If the relay is ON/OFF, the associated devices are ON/OFF |
Defines the voltage level (in Volts) beyond which an overvoltage event is identified and the overvoltage timer is activated. The timer is reset when the event ceases, i.e. when the voltage returns below the overvoltage level. As soon as an overvoltage event occurs, the LED starts a BLUE blinking. If the overvoltage event ceases before the overvoltage timer expires, the blue blinking is stopped, otherwise the alarm is generated and the blinking reset is established by parameter 6. Size: 2 Byte, Default Value: 253
Setting | Description |
---|---|
110 - 260 | Defines the overvoltage level (in Volts) |
Define the time (seconds) in which the voltage must persist above the overvoltage level so that an alarm is generated. Size: 2 Byte, Default Value: 5
Setting | Description |
---|---|
1 - 3600 | Overvoltage time interval (in seconds) after witch an alarm is generated |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Manual when the relay change its state through the Push Button |
1 | When the overvoltage event is terminated |
Define how to control the devices associated to the overvoltage alarm Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | The associated devices are switched OFF |
-1 | The associated devices are switched ON |
1 - 99 | The associated devices (dimmer, roller shutters) are set to the indicated level |
Defines the current level (in Amps) beyond which an overcurrent event is identified and the overcurrent timer is activated. The timer is reset when the event ceases, i.e. when the current returns below the overcurrent level. As soon as an overcurrent event occurs, the led starts a red blinking. If the overcurrent event ceases before the overcurrent timer expires, the red blinking is stopped, otherwise the alarm is generated and the blinking reset is established by parameter 10. Size: 1 Byte, Default Value: 12
Setting | Description |
---|---|
1 - 12 | Defines the overcurrent level (in Amps) |
Define the time (seconds) in which the current must persist above the overcurrent level so that an alarm is generated and the relay is opened. Size: 2 Byte, Default Value: 10
Setting | Description |
---|---|
1 - 3600 | Overcurrent time interval (in seconds) after witch an alarm is generated |
Hardware Platform | ZM5101 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 255 FW: 0.02 |
Z-Wave Version | 6.81.04 |
Certification ID | ZC10-19046462 |
Z-Wave Product Id | 0x0149.0x1214.0x0700 |
Firmware Updatable | Updatable by Consumer by RF |
Supported Meter Type | Electric Energy |
Switch Type | Push Button |
Security V2 | S2_UNAUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |