Quickstart

This is a secure Window Covering - Pos/End Aware for U.S. / Canada / Mexico. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
1. Set primary controller/gateway into inclusion mode (Please refer to your primary controllers manual on how to turn your controller into inclusion).2. Power on the curtain motor controller and set it into inclusion mode. There are two methods to set the curtain motor controller into inclusion mode:1)Triple press the network inclusion/exclusion button, it will set the curtain motor controller into inclusion mode.6 seconds timeout if there is no reply from the Z-Wave primary controller, repeat the operation.2)When the value of configuration parameter 8 is set as 1, triple press the switch connected to S1, it will set the curtain motor controller into inclusion mode. 6 seconds timeout if there is no reply from the Z-Wave primary controller, repeat the operation.3. The curtain motor controller will be added to the Z-Wave network.

Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.


Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.

This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.

If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.

Product Description

The curtain motor controller is a universal, Z-Wave Plus compatible, electric motor controller. The deviceallows for controlling motors of roller blinds and venetian blinds, which are single phase AC powered. Thecurtain motor controller allows for precise positioning of a roller blind or venetian blind slats. Precise positioning is available for the motors equipped with mechanic and electronic end switches. The device also allows for controlling on/off of lights. The module may be controlled wirelessly, through the Z-Wave network primary controller, or through the switch keys connected to it. In addition, the curtain motor controller is equipped with Power Metering and over current protection.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.

Reset to factory default

This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.

Press and hold down network inclusion/exclusion button for over 10 seconds, the curtain motor controllerwill be reset to factory defaults.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.

Inclusion

1. Set primary controller/gateway into inclusion mode (Please refer to your primary controllers manual on how to turn your controller into inclusion).2. Power on the curtain motor controller and set it into inclusion mode. There are two methods to set the curtain motor controller into inclusion mode:1)Triple press the network inclusion/exclusion button, it will set the curtain motor controller into inclusion mode.6 seconds timeout if there is no reply from the Z-Wave primary controller, repeat the operation.2)When the value of configuration parameter 8 is set as 1, triple press the switch connected to S1, it will set the curtain motor controller into inclusion mode. 6 seconds timeout if there is no reply from the Z-Wave primary controller, repeat the operation.3. The curtain motor controller will be added to the Z-Wave network.

Exclusion

1. Set the primary controller/gateway into exclusion mode (Please refer to your primary controllers manual on how to set your controller into exclusion).2. Power on the curtain motor controller and set it into exclusion mode. There are two methods to set the curtain motor controller into exclusion mode:1)Triple press the network inclusion/exclusion button, it will set the curtain motor controller into exclusion mode. 6 seconds timeout if there is no reply from the Z-Wave primary controller, repeat the operation.2)When the value of configuration parameter 8 is set as 1, triple press the switch connected to S1, it will set the curtain motor controller into exclusion mode. 6 seconds timeout if there is no reply from the ZWave primary controller, repeat the operation.3. The curtain motor controller will be removed from the Z-Wave network.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association - one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.

Association Groups:

Group Number Maximum Nodes Description
1 5 1. When press and hold down K2 button for 10S to reset thedevice, send u0022Device Reset Locally Notificationu0022 to associateddevices of this group to report factory reset information.2. When over load detected, send u0022NOTIFICATION_REPORTu0022 toassociated devices of this group.3. Report energy meter actively.4. When action of S1 and S2 is detected, sendCENTRAL_ SCENE_ NOTIFICATION_ V3 to associated devices ofthis group.
2 5 When endpoint 1 state changes, send u0022SWITCH_MULTILEVEL_REPORTu0022 to associated devices of thisgroup.
3 5 When endpoint 2 state changes, sendu0022SWITCH_BINARY_REPORTu0022 to associated devices of this group.

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.

IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.

Parameter 10: Power change absolute threshold report, unit is W

Power change absolute threshold report, unit is W
Size: 1 Byte, Default Value: 10

Setting Description
0 disable absolute threshold report function
1 - 100 value of the power change absolute threshold, if power change value is over the threshold value, report the power change value using METER_REPORT

Parameter 11: Current change absolute threshold, unit is 0.1A

Wiring typeNote: this parameter is read only
Size: 1 Byte, Default Value: 0

Setting Description
0 disable absolute threshold function
1 - 10 value of the current change absolute threshold, if current change value is over the threshold value, report the current change value using METER_REPORT

Parameter 12: Voltage change absolute threshold, unit is 1V

Voltage change absolute threshold, unit is 1V
Size: 1 Byte, Default Value: 0

Setting Description
0 disable absolute threshold function
1 value of the voltage change absolute threshold, if voltage change value is over the threshold value, report the voltage change value using METER_REPORT

Parameter 13: Slats rotation time, unit is 0.1S

Enable/disable over current protection (over 1.5A for 20 seconds continuously)
Size: 1 Byte, Default Value: 15

Setting Description
0 disable the function
5 - 250 value of the slats rotation time This parameter is only valid when parameter 3 is configured as venetian mode (up/down and slats rotation).

Parameter 14: Time cycle to report the values of energy consumption, voltage, current and load power actively

Time cycle to report the values of energyconsumption, voltage, current and load poweractively
Size: 4 Byte, Default Value: 3600

Setting Description
60 - 2678400 value of the time cycle, unit is S.

Parameter 2: Saving load state before power failure

Enable/disable the curtain motor controller to report state change percentage threshold (report only when change value at the specified percentage), if enabled, report when the value reaches both 0% and 99%. When the working mode is configured as light mode, as long as the state changes, the state changepercentage threshold will be reported.SWITCH_MULTILEVEL_REPORT
Size: 1 Byte, Default Value: 1

Setting Description
0 disable to report actively
1 value to report, unit is one percent

Parameter 3: Working mode

Working mode
Size: 1 Byte, Default Value: 2

Setting Description
0 light mode
1 Shutter mode without positioning
2 Shutter mode with positioning
3 venetian mode (up/down and slats rotation)

Parameter 4: Enable/disable to save positioning

Enable/disable to save positioningpercentage, record and save currentpositioning every time when the curtain movesto specified position, if the working mode isconfigured as light mode, record on/off state.
Size: 1 Byte, Default Value: 1

Setting Description
0 disable
1 enable

Parameter 5: Enable/disable over current protection

Enable/disable over current protection0: disable1: enable, when over current detected, thereare two methods to cancel alarm:1. short press either switch button S1 or S2,the alarm will last at least 1 minute and then becancelled.2. re-power on the curtain motor controller
Size: 1 Byte, Default Value: 1

Setting Description
0 disable
1 enable, when over current detected, there are two methods to cancel alarm: 1. short press either switch button S1 or S2, the alarm will last at least 1 minute and then be cancelled. 2. re-power on the curtain motor controller

Parameter 6: starting positioning calibration

Only value 1 can be written in, which meansstarting positioning calibration.When read,0x01: positioning calibration completed0x00: positioning not calibratedThis parameter is only valid when parameter 3configured as shutter mode with positioning orvenetian mode (up/down and slats rotation).
Size: 1 Byte, Default Value: 0

Setting Description
0 positioning not calibrated
1 positioning calibration completed

Parameter 7: When parameter 3 value configured as 0 (light mode), configuration of button S1 and S2 control.

When parameter 3 value configured as 0 (light mode), configuration of button S1 and S2 control.
Size: 1 Byte, Default Value: 0

Setting Description
0 Short press S1 to switch ON/OFF Q1. Press and hold down S1 to switch ON Q1, then release to switch OFF Q2. Short press S2 to switch ON/OFF Q2. Press and hold down S2 to switch ON Q2, then release to switch OFF Q2.
1 Short press S1 to switch ON/OFF Q1. When S1 is pressed and held down, then released, not processed. Short press S2 to switch ON/OFF Q2. When S2 pressed and held down, then released, not processed.
2 Press and hold down S1 to switch ON Q1, then release to switch OFF Q2. When S1 short pressed, not processed. Press and hold down S2 to switch ON Q2, then release to switch OFF Q2. When S2 short pressed, not processed.
3 Short press S1 or S2 to switch ON/OFF of both Q1 and Q2 simultaneously. When S1 or S2 pressed and held down, not processed
4 Press and hold down S1 to switch ON Q1 and Q2. When S1 short pressed, not processed. Press and hold down S2 to switch OFF Q1 and Q2. When S2 short pressed, not processed.

Parameter 8: Enable/disable to add the device to or remove it from a Z-Wave network through button S1.

Enable/disable to add the device to or removeit from a Z-Wave network through button S1.Please refer to the parts of inclusion andexclusion for details.
Size: 1 Byte, Default Value: 1

Setting Description
0 enable
1 disable

Parameter 9: Enable/disable to send scene activation command CENTRAL_ SCENE_ NOTIFICATION_ V3 when the switches S1 and S2 are pressed.

Enable/disable to send scene activation command CENTRAL_ SCENE_ NOTIFICATION_ V3 when the switches S1 and S2 are pressed.
Size: 1 Byte, Default Value: 1

Setting Description
0 disable to send for action of both S1 and S2
1 enable to send for action of both S1 and S2
2 enable to send for action of only S1
3 enable to send for action of only S2

Technical Data

Hardware Platform ZM5101
Device Type Window Covering - Pos/End Aware
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.06
Z-Wave Version 6.71.03
Certification ID ZC10-19046459
Z-Wave Product Id 0x0330.0x0201.0xD00D
Z-Wave Scene Type Scene & Central Scene
Window Covering Control Features Automatic CalibrationPosition AwareSupports CurtainsSupports Horizontal Blinds/LouversSupports Open/Close MotionSupports Up/Down Motion
Supported Notification Types Power ManagementSystem
Supported Meter Type Electric Energy
Firmware Updatable Updatable by Consumer by RF
Security V2 S2_UNAUTHENTICATED
Frequency XXfrequency
Maximum transmission power XXantenna

Supported Command Classes

  • Association Grp Info
  • Association V2
  • Basic
  • Central Scene V3
  • Configuration
  • Device Reset Locally
  • Firmware Update Md V4
  • Manufacturer Specific V2
  • Meter V3
  • Multi Channel Association V3
  • Multi Channel V4
  • Notification V8
  • Powerlevel
  • Scene Activation
  • Scene Actuator Conf
  • Security
  • Security 2
  • Supervision
  • Switch Binary
  • Switch Multilevel V3
  • Transport Service V2
  • Version V2
  • Zwaveplus Info V2

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network. Controllers are typically Gateways,Remote Controls or battery operated wall controllers.
  • Slave — is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators and even remote controls.
  • Primary Controller — is the central organizer of the network. It must be a controller. There can be only one primary controller in a Z-Wave network.
  • Inclusion — is the process of adding new Z-Wave devices into a network.
  • Exclusion — is the process of removing Z-Wave devices from the network.
  • Association — is a control relationship between a controlling device and a controlled device.
  • Wakeup Notification — is a special wireless message issued by a Z-Wave device to announces that is able to communicate.
  • Node Information Frame — is a special wireless message issued by a Z-Wave device to announce its capabilities and functions.