This is a
When the pushbutton is released after a press of (2sec
Master Dimmer iO is ready to operate with Z-Wave controllers and configured to be managed by Simon100 iO APP using the HUB plug iO for getting a better user experience. allowing the control of other Z-Wave devices via Basic Set/Get commands.Available colors Black and White.
Reset to factory default | When the pushbutton is released after a press of (30sec |
Inclusion | When the pushbutton is released after a press of (2sec |
Exclusion | When the pushbutton is released after a press of (2sec |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 3 | Z-Wave Plus LifelineAfter reset the Z-Wave module, a DEVICE-RESET-LOCALLY-NOTIFICATION is sent.Pressing without having nodes associated with the control group is notified by a CENTRAL_SCENE_NOTIFICATION |
2 | 20 | CtrlDuring Association process or then Association Set is receivedCC Manufacturer Specific, Manufacturer Specific Get: (to discover manufacturer)CC Association, Association Set: (review param 28 to know more about this command use).CC Association, Association Remove: (review param 28 to know more about this command use).CC Configuration, Configuration Set Param 1, 0xFF -> when association process is started this Configuration Set will be sent to all Simon devices in group to identify devices involved in this group.CC Configuration, Configuration Set Param 1, 0x00 -> when association process is finished this Configuration Set will be sent to all Simon devices in group to identify devices involved in this group.CC Configuration, Configuration Set Param 1, 0xFF ->Sent when a new device is associated thought association process and this device is a Simon device.CC Configuration, Configuration Set Param 1, 0x00 -> Sent when a device is disassociated thought association process and this device is a Simon device.When Touch area is detected o key is pressed without touch area detection:CC Configuration, Configuration Get, Param 21 -> Sent if param 28 value is 0x00, there is only 1 device is associated and it is a Simon device. Used to know the associated device state.CC Basic, Basic Get -> Sent if param 28 value is 0x00, there is only 1 device is associated and it is not a Simon device. Used to know the associated device state.When pressed and later than knowing the controlled devices state:COMMAND_CLASS_BASIC_SETIt is sent to the associated nodes after a push to change its state:Value: 0xFF to enable / 0x00 to disableIt is relayed to the associated nodes when Z-Wave receives a BASIC_SET.COMMAND_CLASS_MULTILEVEL_SETIt is sent to the associated nodes after a push to change its state:It is relayed to the associated nodes upon receipt by Z-Wave. |
Allows to turn ON or OFF the central LED Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Turns the LED OFF |
255 | Turns the LED ON |
Sets the central led ilumination when the key is in repose state Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | LED OFF |
255 | LED on at 20 percent of maximum level |
Locks or Unlocks the direct control of the load Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Unlock the direct control of load |
255 | Lock the direct control of load |
Resets groups, Z-Wave status, and some or all configurations depending on the configuration value (write only) Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
39015 | Parameters, Groups, and Z-Wave status are restored to default value. |
17170 | Parameters, except Lock long press are restored to default |
Locks or unlocks the manual association Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Unblocked |
255 | Blocked |
Controls the behavior of the product when the key is pressed Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | When short press, switches between the last power on and off (depending on the status of the associated control) by sending a Basic Set to 0x00 or 0xFF to the associated nodes. The Slider does not work. |
1 | When short press, always activates those associated with the last power on by sending a Basic Set to 0xFF |
2 | When short press, always deactivates associates by sending a Basic Set to 0x00 |
4 | When short press, always activates the associated nodes by sending a Basic Set to 0xFFWhen hold press from 2 seconds to 10 seconds always turns off the associated nodes by sending a Basic Set to 0x00. Does not send Node Info nor does the central LED flash. |
5 | The described actions are performed for value 0, but sending the Multilevel Set |
Allows to identify a product using its central LED (write only) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
255 | the central LED blinks for 5 seconds in order to identify the device |
Reports the actual state of the device Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
45056 | Load is OFF |
45057 | Load is ON |
45312 | Lighting percentage level associated node |
Locks or unlocks the long press on the key Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Long press works as described previously |
255 | Long press from 2 seconds to 20 seconds does not send a Node info. With a long press above 30 seconds, all parameters except Lock long press are restored to default and device sends a Node Info. |
Controls if a state of an associated device or devices will be consulted when touch is detected Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | If there is 1 Associated device, when Touch is detected, controlled device state will be consulted |
255 | If there is 1 Associated device, when Touch is detected, controlled device state is not consulted. |
Enables or disables the Central Scene Command Class Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Enables CC Central Scene Notification when there are no nodes associated with the control group and Inhibits error signaling by pressing less than 2 seconds if there are no associated nodes. |
255 | Enables error signaling by pressing less than 2 seconds if there are no associated nodes |
Hardware Platform | ZM5202 |
Device Type | Wall Controller |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 4.24:79.50 |
Z-Wave Version | 6.51.07 |
Certification ID | ZC10-19046443 |
Z-Wave Product Id | 0x0267.0x0008.0x0000 |
Z-Wave Scene Type | Central Scene |
Firmware Updatable | Updatable by Professional/Technician |
Neutral Wire Required | ok |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |