Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Simon iO Dimmer is integrated by Electronic Dimmer and a Rocker,that provides Z-Wave communication attributes. The touch surface offers an slider area in order to adjust the light level showing the dimming intensit y with 7 LEDs . Simon iO Dimmer is ready to operate with Z-Wave controllers and configured to be managed by Simon100 IO APP using the HUB plug IO for getting a better user experience.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
When the pushbutton is released after a press of (30sec
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 3 | Z-Wave Plus Lifeline- On -> CC Basic, Basic Report, Value 0x01 - 0x63 Report the dimming level- Off -> CC Basic, Basic Report, Value 0x00Instant Power Consumption vary over 10% and is stable almost 2sec- CC Meter, Meter Report, Electric meter, Consumed, Watts, Size 4, Precision 1, Value (W)Calibration requirement change. (If device needs to be calibrated and is Added into a Z-Wave network, it will report after receive an Association Set of life line).- Calibration required -> CC Configuration, Configuration Report, Param 23, Value 0xFF- Calibration not required -> CC Configuration, Configuration Report, Param 23, Value 0x00After reset the Z-Wave module, a DEVICE-RESET-LOCALLY-NOTIFICATION is sent. |
2 | 20 | CtrlOn/Off Report when load state is changed:- On -> CC Basic, Basic Report, Value 0x01 - 0x63 Report the dimming level- Off -> CC Basic, Basic Report, Value 0x00 |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Allows to turn ON or OFF the central LED Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Turns the LED OFF |
1 - 255 | Turns the central LED ON |
Sets the delay time to turn on the light Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Instantly. Disable timming |
1 - 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution |
128 - 254 | 1 second (0x80) to 127 minutes (0xFE) in 1 minute resolution |
Sets the time the light stays on. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Instantly. Disable timming |
1 - 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution |
128 - 254 | 1 second (0x80) to 127 minutes (0xFE) in 1 minute resolution |
Sets the central led ilumination when the key is in repose state Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | LED OFF |
1 - 255 | Central LED on at 20% of maximum level |
Lock or Unlock the direct control of the load Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Unlock the direct control of load |
1 - 255 | Lock the direct control of load |
Resets groups, Z-Wave status, and some or all configurations depending on the configuration value (write only) Size: 1 Byte, Default Value: 39015
Setting | Description |
---|---|
39015 | Parameters, Groups, and Z-Wave status are restored to default. |
17170 | Parameters, Groups, and Z-Wave status are restored to default. |
Sets the delay time to turn off the light Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Instantly. Disable timming |
1 - 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution |
128 - 254 | 1 second (0x80) to 127 minutes (0xFE) in 1 minute resolution |
Controls the behavior of the product when the key is pressed Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 | When short press, the device toggles the load. The Slider does not work. |
1 | When short press, the device turns ON the load. The Slider does not work |
2 | When short press, the device turns OFF the load. The Slider does not works |
4 | When short press, the device turns ON the load. When hold press from 2seconds to 10seconds device turns OFF the load. The Slider does not works with this configuration, the device will not send the Node Info neither Show the LEDs feedback with this press action. The Slider does not work |
5 | When short press, the device toggles the load. The Slider dims the load when it is ON |
Allows to identify a product using its central LED (write only) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
255 | the central LED blinks for 5 seconds in order to identify the device |
Reports the state of the charge (read only) Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
45056 | Load is OFF |
45057 | Load is ON |
45312 - 45411 | Last active dimming value |
Reports if calibration is required or not (read only) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Calibration is not required |
255 | It is necessary to calibrate the dimmer to work properly |
Locks or unlocks the long press on the key Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Long press works as described previously |
255 | Long press of from 2 seconds to 10 seconds does not send a the Node Info. Long press of t>30s Parameters, except Lock long press are restored to default and device send a Node Info. |
Sets the time it takes to turn on the light (ramp time) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Instantly. Disable timming |
1 - 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution |
128 - 254 | 1 second (0x80) to 127 minutes (0xFE) in 1 minute resolution |
Sets the time it takes to turn off the light (ramp time) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Instantly. Disable timming |
1 - 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution |
128 - 254 | 1 second (0x80) to 127 minutes (0xFE) in 1 minute resolution |
Sets the minimun dimming value Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 - 98 | Once the devices gets a value through Z-Wave it Scales the value read according this minimum margin |
Sets the maximum dimming value Size: 1 Byte, Default Value: 99
Setting | Description |
---|---|
2 - 99 | Once the devices gets a value through Z-Wave it Scales the value read according this maximum margin |
Returns or sets the last non zero dimming value. In case of Set the device turns ON the load. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 - 127 | returns or sets the last non zero dimming value. In case of Set the device turns ON the load |
Performs a device calibration Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Device performs calibration using Trailing and leading Edge and decides which one is better |
2 | Device performs calibration using Trailing and leading Edge and decides which one is better |
3 | Device is calibrated using Leading Edge |
Hardware Platform | ZM5202 |
Device Type | Light Dimmer Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 4.24:78.59:70.48 |
Z-Wave Version | 6.51.07 |
Certification ID | ZC10-19046438 |
Z-Wave Product Id | 0x0267.0x0007.0x0000 |
Firmware Updatable | Updatable by Professional/Technician |
Supported Meter Type | Electric Energy |
Electric Load Type | Dimmable ELV (Magnetic)Dimmable LEDDimmable MLV (Magnetic)Incandescent |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |