This is a
Turn the primary controller of Z-Wave network into inclusion mode, short press the products Action button that you can find on the product's housing.
Aeotec Heavy Duty Smart Switch Gen5 is a Z-Wave switch controller that can also report the wattage energy usage and KWH usage of the device wired in to it. As part of its switching functionality, Heavy Duty Smart Switch Gen5 can be controlled by other Z-Wave devices to turn loads on or off. It can bear up to 40 amps current of resister loads.It also act as a repeater, forwarding Z-Wave command messages to destination nodes if the originating controller is out of range from the destination node.By taking advantage of the Z-Wave mesh network, commands can be routed to their destination via intermediary Z-Wave products. Products that are Z-Wave certified can be used and communicate with other Z-Wave certified device.The Switch is also a security Z-wave device and supports Over The Air (OTA) feature for the products firmware upgrade.
Reset to factory default | Press and hold the Action button that you can find on the product's housing for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable. |
Inclusion | Turn the primary controller of Z-Wave network into inclusion mode, short press the products Action button that you can find on the product's housing. |
Exclusion | Turn the primary controller of Z-Wave network into exclusion mode, short press the products Action button that you can find on the product's housing. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline.The Hial CC and Basic Report CC (configured by parameter 80) can be sent to the associatd nodes in this group. |
2 | 5 | Forward the Basic Set, Switch Binary Set or Scene Activation Set to associated nodes in Group 2 when the Smart Switch receives the Basic Set, Switch Binary Set, Scene Activation Set commands from main controller |
Reset the parameters 101-103. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Reset the parameters 101-103. |
To set which report would be sent in Report group 1 Size: 4 Byte, Default Value: 4
Setting | Description |
---|---|
1 | Send Meter Report of Voltage |
2 | Send Meter Report of Current |
4 | Send Meter Report of Watt |
8 | Send Meter Report of kWh |
To set which report would be sent in Report group 2 Size: 4 Byte, Default Value: 8
Setting | Description |
---|---|
1 | Send Meter Report of Voltage |
2 | Send Meter Report of Current |
4 | Send Meter Report of Watt |
8 | Send Meter Report of kWh |
To set which report would be sent in Report group 3 Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Send Meter Report of Voltage |
2 | Send Meter Report of Current |
4 | Send Meter Report of Watt |
8 | Send Meter Report of kWh |
Reset the parameters 111-113 to default values. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Reset the parameters 111-113 to default values. |
Set the time interval of sending Report Size: 4 Byte, Default Value: 5
Setting | Description |
---|---|
1 - 2147483647 | Interval Seconds |
Set the time interval of sending Report Size: 4 Byte, Default Value: 120
Setting | Description |
---|---|
1 - 2147483647 | Interval Seconds |
Set the time interval of sending Report Size: 4 Byte, Default Value: 120
Setting | Description |
---|---|
1 - 2147483647 | Interval Seconds |
Configure the output load status after re-power on Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | The last status before the power outage. |
1 | Always on |
2 | Always off |
PartnerID Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Aeon Labs Standard Product |
1 - 127 | Others |
Enable/disable Configuration Locked Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
Reset the Smart Switch 6 to factory default. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Reset all configuration parameters to default. |
1431655765 | Reset the Smart Switch to factory default |
Current Overload Protection. Output load will be closed after 2 minutes if the current overruns (US: 16.5A, AU: 10.5A, EU: 14A). Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disabled |
1 | Enabled |
To set which notification would be sent to the associated nodes in association group 1 when the state of output load is changed. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Nothing |
1 | Hail CC |
2 | Basic Report CC |
Enable/disable the parameter 91 and 92. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
The value here represents minimum change in wattage (in terms of wattage) to induce a Meter Report Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
0 - 32767 | The threshold can be set from 0 to 32767 watt. |
The value here represents minimum change in wattage percent (in terms of percentage) to induce a Meter Report Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 - 100 | The threshold can be set from 0 to 100%. |
Hardware Platform | ZM5202 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 78 FW: 3.28 |
Z-Wave Version | 6.51.10 |
Certification ID | ZC10-19036399 |
Z-Wave Product Id | 0x0086.0x0903.0x004E |
Supported Meter Type | Electric Energy |
Sensors | Air Temperature |
Firmware Updatable | Updatable by Consumer by RF |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |