Quickstart

This is a secure On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
Turn the primary controller of Z-Wave network into inclusion mode, short press the products Action button that you can find on the product's housing.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Aeotec Heavy Duty Smart Switch Gen5 is a Z-Wave switch controller that can also report the wattage energy usage and KWH usage of the device wired in to it. As part of its switching functionality, Heavy Duty Smart Switch Gen5 can be controlled by other Z-Wave devices to turn loads on or off. It can bear up to 40 amps current of resister loads.It also act as a repeater, forwarding Z-Wave command messages to destination nodes if the originating controller is out of range from the destination node.By taking advantage of the Z-Wave mesh network, commands can be routed to their destination via intermediary Z-Wave products. Products that are Z-Wave certified can be used and communicate with other Z-Wave certified device.The Switch is also a security Z-wave device and supports Over The Air (OTA) feature for the products firmware upgrade.

Reset to factory default Press and hold the Action button that you can find on the product's housing for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable.
Inclusion Turn the primary controller of Z-Wave network into inclusion mode, short press the products Action button that you can find on the product's housing.
Exclusion Turn the primary controller of Z-Wave network into exclusion mode, short press the products Action button that you can find on the product's housing.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plus Lifeline.The Hial CC and Basic Report CC (configured by parameter 80) can be sent to the associatd nodes in this group.
2 5 Forward the Basic Set, Switch Binary Set or Scene Activation Set to associated nodes in Group 2 when the Smart Switch receives the Basic Set, Switch Binary Set, Scene Activation Set commands from main controller

Configuration Parameters

Parameter 100: Reset the parameters 101-103

Reset the parameters 101-103.
Size: 1 Byte, Default Value: 0

Setting Description
0 Reset the parameters 101-103.

Parameter 101: To set which report would be sent in Report group 1

To set which report would be sent in Report group 1
Size: 4 Byte, Default Value: 4

Setting Description
1 Send Meter Report of Voltage
2 Send Meter Report of Current
4 Send Meter Report of Watt
8 Send Meter Report of kWh

Parameter 102: To set which report would be sent in Report group 2

To set which report would be sent in Report group 2
Size: 4 Byte, Default Value: 8

Setting Description
1 Send Meter Report of Voltage
2 Send Meter Report of Current
4 Send Meter Report of Watt
8 Send Meter Report of kWh

Parameter 103: To set which report would be sent in Report group 3

To set which report would be sent in Report group 3
Size: 4 Byte, Default Value: 0

Setting Description
1 Send Meter Report of Voltage
2 Send Meter Report of Current
4 Send Meter Report of Watt
8 Send Meter Report of kWh

Parameter 110: Reset the parameters 111-113

Reset the parameters 111-113 to default values.
Size: 1 Byte, Default Value: 0

Setting Description
0 Reset the parameters 111-113 to default values.

Parameter 111: Set the time interval of sending Report

Set the time interval of sending Report
Size: 4 Byte, Default Value: 5

Setting Description
1 - 2147483647 Interval Seconds

Parameter 112: Set the time interval of sending Report

Set the time interval of sending Report
Size: 4 Byte, Default Value: 120

Setting Description
1 - 2147483647 Interval Seconds

Parameter 113: Set the time interval of sending Report

Set the time interval of sending Report
Size: 4 Byte, Default Value: 120

Setting Description
1 - 2147483647 Interval Seconds

Parameter 20: Configure the output load status after re-power on

Configure the output load status after re-power on
Size: 1 Byte, Default Value: 0

Setting Description
0 The last status before the power outage.
1 Always on
2 Always off

Parameter 200: PartnerID

PartnerID
Size: 1 Byte, Default Value: 0

Setting Description
0 Aeon Labs Standard Product
1 - 127 Others

Parameter 252: Enable/disable Configuration Locked

Enable/disable Configuration Locked
Size: 1 Byte, Default Value: 0

Setting Description
0 Disable
1 Enable

Parameter 255: Reset the Smart Switch 6

Reset the Smart Switch 6 to factory default.
Size: 1 Byte, Default Value: 0

Setting Description
1 Reset all configuration parameters to default.
1431655765 Reset the Smart Switch to factory default

Parameter 3: Current Overload Protection.

Current Overload Protection. Output load will be closed after 2 minutes if the current overruns (US: 16.5A, AU: 10.5A, EU: 14A).
Size: 1 Byte, Default Value: 0

Setting Description
0 Disabled
1 Enabled

Parameter 80: To set which notification would be sent to the associated nodes in association group 1

To set which notification would be sent to the associated nodes in association group 1 when the state of output load is changed.
Size: 1 Byte, Default Value: 0

Setting Description
0 Nothing
1 Hail CC
2 Basic Report CC

Parameter 90: Enable/disable the parameter 91 and 92

Enable/disable the parameter 91 and 92.
Size: 1 Byte, Default Value: 1

Setting Description
0 Disable
1 Enable

Parameter 91: Induce an automatic report

The value here represents minimum change in wattage (in terms of wattage) to induce a Meter Report
Size: 2 Byte, Default Value: 50

Setting Description
0 - 32767 The threshold can be set from 0 to 32767 watt.

Parameter 92: Induce an automatic report

The value here represents minimum change in wattage percent (in terms of percentage) to induce a Meter Report
Size: 1 Byte, Default Value: 10

Setting Description
0 - 100 The threshold can be set from 0 to 100%.

Technical Data

Hardware Platform ZM5202
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 78 FW: 3.28
Z-Wave Version 6.51.10
Certification ID ZC10-19036399
Z-Wave Product Id 0x0086.0x0903.0x004E
Supported Meter Type Electric Energy
Sensors Air Temperature
Firmware Updatable Updatable by Consumer by RF
Frequency XXfrequency
Maximum transmission power XXantenna
IndiaOn/Off Power Switch