Quickstart
This is a
secure
Notification Sensor for XXXQFrequencyName.
To run this device please make sure the internal battery is fully charged.
To add this device to your network execute the following action:
Press once TriSensors Action Button. If it is the first installation, the yellow LED will keep solid until whole network processing is complete. If successful, the LED will flash white -> green -> white -> green, after 2 seconds finished. If failed, the yellow LED lasts for 30 seconds, then the green LED flashes once.If it is the S2 encryption network, please enter the first 5 digits of DSK.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from
Z-Wave Alliance Product
data and may be incomplete. Please refer to the
Manufacturers Manual for more information.
Product Description
Aeotec TriSensor is a universal Z-Wave Plus compatible product, consists of temperature, lighting and motion sensors, powered by a CR123A battery. It can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. By the built-in motion sensor, an alam will be sent to the gateway when the motion sensor is triggered.
Reset to factory default |
1.Power up the device.2.Press and hold the button for 15s until Red Led is blinking,then release the button. Note: Please use this procedure only when the network primary controller is missing or otherwise inoperable. |
Inclusion |
Press once TriSensors Action Button. If it is the first installation, the yellow LED will keep solid until whole network processing is complete. If successful, the LED will flash white -> green -> white -> green, after 2 seconds finished. If failed, the yellow LED lasts for 30 seconds, then the green LED flashes once.If it is the S2 encryption network, please enter the first 5 digits of DSK. |
Exclusion |
Press once TriSensors Action Button, the Purple LED will keep solid until whole network processing is complete. If the exclusion is successful, the LED will flash white -> green ->white -> green and then LED will pulse a blue. If failed, the yellow LED lasts for 30 seconds, then the green LED flashes once. |
NIF |
XXXNIF |
Wakeup |
Press and hold the button at least 2s until Red Led is on and then release the button,device will send wakeup notification to controller if device is in a Z-Wave network. |
Protection |
XXXProtection |
FirmwareUpdate |
XXXFirmwareUpdate |
SetAssociation |
XXXSetAssociation |
Association Groups:
Group Number |
Maximum Nodes |
Description |
1 |
5 |
Group 1 is lifeline group; all nodes which associated in this group will receive the messages sent by device throughlifeline.CommandClass:COMMAND_CLASS_NOTIFICATION COMMAND_CLASS_SENSOR_BINARY COMMAND_CLASS_SENSOR_MULTILEVEL COMMAND_CLASS_BATTERY COMMAND_CLASS_DEVICE_RESET_LOCALLYCommand:NOTIFICATION_REPORTSENSOR_BINARY_REPORT SENSOR_MULTILEVEL_REPORT BATTERY_REPORT DEVICE_RESET_LOCALLY_NOTIFICATION |
2 |
5 |
Group 2 is controlling group, all nodes associated in this group will be controlled through BASIC_SET command by the device when device detects a movement event. Basic Set Value is decided by Configuration Parameter 6.CommandClass:COMMAND_CLASS_BASIC (HomeSecurity)Command:BASIC_SET |
3 |
5 |
Group 3 is controlling group, all nodes associated in this group will be controlled through BASIC_SET command by the device when device detects an ambient temperature alarm (Decided by Configuration Parameter 7).CommandClass:COMMAND_CLASS_BASIC(Temperature)Command:BASIC_SET |
Technical Data
Hardware Platform |
ZM5101 |
Device Type |
Notification Sensor |
Network Operation |
Reporting Sleeping Slave |
Firmware Version |
HW: 17 FW: 2.07:01.64 |
Z-Wave Version |
6.71.01 |
Certification ID |
ZC10-19026380 |
Z-Wave Product Id |
0x0371.0x1C02.0x0005 |
Firmware Updatable |
Updatable by Consumer by RF |
Sensors |
Air TemperatureLuminanceMotion/No Motion (Binary) |
Supported Notification Types |
Home Security |
Color |
White |
Frequency |
XXfrequency |
Maximum transmission power |
XXantenna |