1, Refer to your primary controller to enter into the Inclusion Mode or Exclusion Mode2,When it is prompted to enter it, please triple click the PROG button within 1 second.3,Green Indicator flashes TWICE then stay off
PAR01, AC Master Lite, is a Z-Wave plus compliant Z-Wave-to-IR Bridge to control split air conditioner by receiving Z-Wave command and translating to Infrared command. With its comprehensive built-In and cloud-stored IR database (library). PAR01 can control different brands and models of air conditioners worldwide.PAR01 is a security enabled Z-Wave plus device. A security Enabled Z-Wave Plus Controller must be used in order to fully utilize the product.PAR01 is a Z-Wave slave device, it depends on gateway to setup particular AC brand with correct IR code. Different gateway has different user interface for setup.
Reset to factory default | Press and Hold PROG button for 3 seconds on AC Master Lite, the Green Indicator will light up. DO NOT Release the PROG Button until Green Indicator flashes TWICE.Remark : Please use this procedure only when the network primary controller is missing or otherwise incoperable. |
Inclusion | 1, Refer to your primary controller to enter into the Inclusion Mode or Exclusion Mode2,When it is prompted to enter it, please triple click the PROG button within 1 second.3,Green Indicator flashes TWICE then stay off |
Exclusion | 1, Refer to your primary controller to enter into the Inclusion Mode or Exclusion Mode2,When it is prompted to enter it, please triple click the PROG button within 1 second.3,Green Indicator flashes TWICE then stay off |
NIF | XXXNIF |
Wakeup | Press the "PROG" button to Wakeup the unit |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Z-Wave Plus Lifeline |
Default: 0x0000range: (0x0000 to 0x01B6)refer to learning mapping table Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 32 | Storage Location |
Default: 0x00range: 0 to 4 (0x00 to 0x04)0(0x00) : Idle - IR Channel is idle1(0x01) : OK - the last learning operation was completed successfully2(0x02) : Learning - PAR01- is busy processing previous learning request3(0x03) : FullAll locations are being used.4(0x04) : The last learning request was failedNote:The status value 0x01 and 0x04 will be reset to 0x00 after PAR01 receives a get command to this parameter. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 4 | Read Only |
Refer to Code Finder Webpage Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 65535 | IR Code Number |
0(0x00) = Disable (Default)(for saving battery life)Auto report if room temperature is different from last report.1(0x01) = 1F (0.5C)2(0x02) = 2F (1C) 3(0x03) = 3F (1.5C)4(0x04) = 4F (2C)5(0x05) = 5F (2.5C)6(0x06) = 6F (3C)7(0x07) = 7F (3.5C)8(0x08) = 8F (4C) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 8 | Temp change |
Default: 0xFF0 or 255(0x00 or 0xFF)0(0x00): Disable255(0xFF): Enable (Default) Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 | Disable |
255 | Enable |
Default: 0x01Range 0 to 1 (0x00 or 0x01)0(0x00) : Swing OFF1(0x01) : Swing Auto (Default) Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Swing OFF |
1 | Swing Auto |
Auto report by the following time interval.1(0x01) = 1 Hr2(0x02) = 2 Hrs3(0x03) = 3 Hrs4(0x04) = 4 Hrs5(0x05) = 5 Hrs6(0x06) = 6 Hrs7(0x07) = 7 Hrs8(0x08) = 8 Hrs (Default) Size: 1 Byte, Default Value: 8
Setting | Description |
---|---|
1 - 8 | Hours |
Temperature offset value.0(0x00) = 0C (Default)1(0x01) = 1C2(0x02) = 2C3(0x03) = 3C4(0x04) = 4C5(0x05) = 5C255(0xFF) = -1C254(0xFE) = -2C253(0xFD) = -3C252(0xFC) = -4C251(0xFB) = -5C Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 5 | Positive range |
251 - 255 | Negative range |
Hardware Platform | SD3502 |
Device Type | Thermostat - HVAC |
Network Operation | Listening Sleeping Slave |
Firmware Version | HW: 0 FW: 1.04:01.07:182.03 |
Z-Wave Version | 6.61.00 |
Certification ID | ZC10-19016349 |
Z-Wave Product Id | 0x013C.0x0102.0x8290 |
Thermostat Modes | AutoAwayCoolDry AirFan OnlyHeatResume |
Firmware Updatable | Updatable by Consumer by RF |
Color | White |
Thermostat HVAC Systems Supported | |
Sensors | Air Temperature |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |