This is a secure On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
Add for inclusion (non-security and security):1)Connect the power supply.2)Set the Z-Wave network main controller into learning mode.3)Triple click the Z-button, the LED indicator will be flashing 3 times in Blue.4)Smart Plug should be recognized and included into the Z-Wave network.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Smart Plug is a Z-Wave Switch plugin module specifically used to enable Z-Wave command and control (on/off) of any plug-in tool. It can report wattage consumption or kWh energy usage. This device is a security enabled Z-Wave Plus product that is able to use encrypted Z-Wave Plus messages to communicate to other security enabled Z-Wave Plus products.Smart Plug is also a security Z-Wave device and supports the Over The Air (OTA) feature for the products firmware upgrade.This device must be used in conjunction with a Security Enabled Z-Wave Controller in order to fully utilize all implemented functions.Features:1) AC output switch on/off by manual or Z-Wave command;2) RGB LED indicates the Z-WAVE network range and load power;3) Support S0 and S2 security network;4) Supporting power meter;5) Supporting repeater role;6) Supporting firmware OTA;7) Supporting Smart Start;8) Supports over-current protection

Reset to factory default Long press the button for 20 seconds and the blue LED will speed up the flash and then LED will keep on for 3 seconds in blue and Smart Plug will send Device Reset Locally Notification to the main controller and exclude from the Z-Wave network, this procedure will reset Smart Plug to factory default. Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Inclusion Add for inclusion (non-security and security):1)Connect the power supply.2)Set the Z-Wave network main controller into learning mode.3)Triple click the Z-button, the LED indicator will be flashing 3 times in Blue.4)Smart Plug should be recognized and included into the Z-Wave network.
Exclusion 1) Insert the Plug into a socket.2) Set the Z-Wave network controller into the exclusion mode. 3) Triple click the Z button.4) LED will blink in blue for 3 times, and then start slow flashing to indicate that the remove for exclusion is successful. LED will indicate network status after it is removed from Z-Wave network.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plus Lifeline

Configuration Parameters

Parameter 151: Threshold of power report

Power threshold to be interpreted, when the change value of load power exceeds the setting threshold, the smart plug will send meter report to association device (Group Lifeline).
Size: 2 Byte, Default Value: 50

Setting Description
0 - 200 Available settings: 0 - 200 (0 - 200W)
0 0 - The function is disabled.

Parameter 152: Percentage threshold of power report

Power percentage threshold to be interpreted, when change value of the load power exceeds the setting threshold, the smart plug will send meter report to association device (Group Lifeline).
Size: 1 Byte, Default Value: 10

Setting Description
0 - 100 Available settings: 0 - 100 (0 - 100%)
0 The function is disabled.

Parameter 171: Power report frequency

The interval of sending power report to association device (Group Lifeline).
Size: 4 Byte, Default Value: 3600

Setting Description
3600 - 2678400 Available settings: 3600- 2678400 (3600 - 2678400s)
0 The function is disabled.

Parameter 172: Energy report frequency

The interval of sending energy report to association device (Group Lifeline).
Size: 4 Byte, Default Value: 7200

Setting Description
3600 - 2678400 Available settings: 3600- 2678400 (3600 - 2678400s)
0 The function is disabled.

Parameter 173: Voltage report frequency

The interval of sending voltage report to association device (Group Lifeline).
Size: 4 Byte, Default Value: 0

Setting Description
3600 - 2678400 Available settings: 3600- 2678400 (3600 - 2678400s)
0 The function is disabled.

Parameter 174: Electricity report frequency

The interval of sending electricity report to association device (Group Lifeline).
Size: 4 Byte, Default Value: 0

Setting Description
3600 - 2678400 Available settings: 3600- 2678400 (3600 - 2678400s)
0 The function is disabled.

Parameter 20: Overload protection

Smart Plug keep detecting the load power, once the AC current exceeds 11.5A for more than 5s, smart plug's relay will turn off.
Size: 1 Byte, Default Value: 1

Setting Description
0 The function is disabled
1 The function is enabled.

Parameter 21: Setting device status after power failure

Define how the Plug reacts after the power supply is back on.
Size: 1 Byte, Default Value: 0

Setting Description
0 Smart Plug memorizes its state after a power failure.
1 Smart Plug does not memorize its state after a power failure. Connected device will be on after the power supply is reconnected.
2 Smart Plug does not memorize its state after a power failure. Connected device will be off after the power supply is reconnected.

Parameter 24: Notification when Load status change

Smart Plug can send notifications to association device (Group Lifeline) when state of smart plugs load change.
Size: 1 Byte, Default Value: 1

Setting Description
0 The function is disabled.
1 Send Basic report.
2 Send Basic report only when Load condition is not changed by Z-WAVE Command.

Parameter 254: Enable/disable the configuration command

Lock/unlock all configuration parameters.
Size: 1 Byte, Default Value: 0

Setting Description
0 Unlock
1 Lock

Parameter 27: Indicator modes

After smart plug being included into a Z-Wave network, the RGB LED indicator will indicator the situation of load.
Size: 1 Byte, Default Value: 0

Setting Description
0 The indicator light remains the same as the load on/off status. When the load is on, the light is on, and the off is off.
1 Within 5 seconds after the operation load, the indicator light is consistent with the load on/off status, and then the indicator is off.

Technical Data

Hardware Platform ZM5202
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.02
Z-Wave Version 6.81.01
Certification ID ZC10-19016348
Z-Wave Product Id 0x0208.0x0100.0x0019
Firmware Updatable Updatable by Consumer via Internet
Communications Protocol Z-Wave Serial API
Color White
Electric Load Type Dimmable ELV (Magnetic)Dimmable FluorescentDimmable LEDDimmable MLV (Magnetic)ELV (Electronic)FluorescentIncandescentInductive (e.g. Motor)LEDMLV (Magnetic)
Switch Type Push Button Illuminated
Supported Meter Type Electric Energy
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)On/Off Power Switch