Quickstart

This is a On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
Inclusion the ZW47 from the existing Z-Wave home control network with your primary controller.---Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.---When prompted by your primary controller, click the PROG button Three times in one second.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

It is smart plug type device controlled by Z-Wave controller and can be configured in Z-Wave sensor network, if Z-Wave certified controller features remote access, you can dim lights at home from your mobile phone separately, and manual dim light by push button .

Reset to factory default Press the button twice quickly and then press and hold the button 10S.device will resetPlease use this procedure only when the network primary controller is missing or otherwise inoperable
Inclusion Inclusion the ZW47 from the existing Z-Wave home control network with your primary controller.---Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.---When prompted by your primary controller, click the PROG button Three times in one second.
Exclusion Exclusion the ZW47 from the existing Z-Wave home control network with your primary controller.---Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.---When prompted by your primary controller, click the PROG button Three times in one second.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Z-Wave Plus Lifeline
2 5 basic set commandWhen the output of the ZW47 Enpoint1 socket is changed, On (0xFF) or Off (0x00)orOverload, The ZW47 will automatically send out a relatedbasic set command. On (0xFF) or Off (0x00) to its associated group.
3 5 basic set commandWhen the output of the ZW47 Enpoint2 socket is changed, On (0xFF) or Off (0x00)orOverload, The ZW47 will automatically send out a relatedbasic set command. On (0xFF) or Off (0x00) to its associated group.

Configuration Parameters

Parameter 1: Restores state after power failure

Restores state after power failure
Size: 1 Byte, Default Value: 0

Setting Description
0 The state before a power outage.
1 outlet on
2 outlet off

Parameter 10: Endpoint1 Enable Auto Turn-ON Timer

Endpoint1 Enable Auto Turn-ON Timer
Size: 1 Byte, Default Value: 0

Setting Description
0 EP1 Auto Turn-ON Timer Disabled
1 EP1 Auto Turn-ON Timer Enabled

Parameter 11: Endpoint1 Count Down Configuration(Turn on the output by time

Endpoint1 Count Down Configuration(Turn on the output by time
Size: 4 Byte, Default Value: 60

Setting Description
1 - 65535 Endpoint1 Count Down Configuration(Turn on the output by time

Parameter 12: Endpoint2 Enable Auto Turn-OFF Timer

Endpoint2 Enable Auto Turn-OFF Timer
Size: 1 Byte, Default Value: 0

Setting Description
0 EP2 Auto Turn-OFF Timer Disabled
1 EP2 Auto Turn-OFF Timer Enabled

Parameter 13: Endpoint2 Count Down Configuration(Turn off the output by time

Endpoint2 Count Down Configuration(Turn off the output by time
Size: 4 Byte, Default Value: 60

Setting Description
1 - 65535 Endpoint2 Count Down Configuration(Turn off the output by time

Parameter 14: Endpoint2 Enable Auto Turn-ON Timer

`Endpoint2 Enable Auto Turn-ON Timer
Size: 1 Byte, Default Value: 0

Setting Description
0 EP2 Auto Turn-ON Timer Disabled
1 EP2 Auto Turn-ON Timer Enabled

Parameter 15: Endpoint2 Count Down Configuration(Turn on the output by time

Endpoint2 Count Down Configuration(Turn on the output by time
Size: 4 Byte, Default Value: 60

Setting Description
1 - 65535 Endpoint2 Count Down Configuration(Turn on the output by time

Parameter 16: Manual Control

Manual Control
Size: 1 Byte, Default Value: 1

Setting Description
0 Manual Control Disabled
1 Manual Control Enabled

Parameter 17: Status LED Configuration

Status LED Configuration
Size: 1 Byte, Default Value: 1

Setting Description
0 LED indicator will display power consumption whenever the device is plugged in
1 LED indicator will display power consumption whenever the device is ON in and will turn off when the plug is OFF
2 LED indicator will display the level of power consumption for 5 seconds only whenever the device is turned on or off
3 Always OFF

Parameter 2: Power Wattage Report Value Threshold(Wattage)

Power Wattage Report Value Threshold(Wattage)
Size: 4 Byte, Default Value: 10

Setting Description
0 - 10 Power Wattage Report Value Threshold(Wattage)

Parameter 4: Energy (kWh) Report Frequency (Timer)

Energy (kWh) Report Frequency (Timer)
Size: 4 Byte, Default Value: 300

Setting Description
30 - 2678400 Energy (kWh) Report Frequency (Timer)

Parameter 5: Voltage (V) Report Frequency (Timer)

Voltage (V) Report Frequency (Timer)
Size: 4 Byte, Default Value: 300

Setting Description
30 - 2678400 Voltage (V) Report Frequency (Timer)

Parameter 6: Electricity (A) Report Frequency (Timer)

Electricity (A) Report Frequency (Timer)
Size: 4 Byte, Default Value: 300

Setting Description
0 - 30 Power Wattage Report Value Threshold(Wattage)
30 - 2678400 Electricity (A) Report Frequency (Timer)

Parameter 7: Overload Protection (Current)

Overload Protection (Current)
Size: 1 Byte, Default Value: 13

Setting Description
1 - 16 Overload Protection (Current)

Parameter 8: Endpoint1 Enable Auto Turn-OFF Timer

Endpoint1 Enable Auto Turn-OFF Timer
Size: 1 Byte, Default Value: 0

Setting Description
0 EP1 Auto Turn-OFF Timer Disabled
1 EP1Auto Turn-OFF Timer Enabled

Parameter 9: Endpoint1 Count Down Configuration(Turn off the output by time

Endpoint1 Count Down Configuration(Turn off the output by time
Size: 4 Byte, Default Value: 60

Setting Description
1 - 65535 Endpoint1 Count Down Configuration(Turn off the output by time

Technical Data

Hardware Platform ZM5202
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 255 FW: 1.00
Z-Wave Version 6.71.03
Certification ID ZC10-18116324
Z-Wave Product Id 0x0312.0xA000.0xA003
Electric Load Type FluorescentIncandescentInductive (e.g. Motor)LED
Color White
Supported Meter Type Electric Energy
Firmware Updatable Updatable by Consumer by RF
Supported Notification Types Power Management
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoOn/Off Power Switch