This is a
Inclusion the ZW47 from the existing Z-Wave home control network with your primary controller.---Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.---When prompted by your primary controller, click the PROG button Three times in one second.
It is smart plug type device controlled by Z-Wave controller and can be configured in Z-Wave sensor network, if Z-Wave certified controller features remote access, you can dim lights at home from your mobile phone separately, and manual dim light by push button .
Reset to factory default | Press the button twice quickly and then press and hold the button 10S.device will resetPlease use this procedure only when the network primary controller is missing or otherwise inoperable |
Inclusion | Inclusion the ZW47 from the existing Z-Wave home control network with your primary controller.---Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.---When prompted by your primary controller, click the PROG button Three times in one second. |
Exclusion | Exclusion the ZW47 from the existing Z-Wave home control network with your primary controller.---Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.---When prompted by your primary controller, click the PROG button Three times in one second. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Z-Wave Plus Lifeline |
2 | 5 | basic set commandWhen the output of the ZW47 Enpoint1 socket is changed, On (0xFF) or Off (0x00)orOverload, The ZW47 will automatically send out a relatedbasic set command. On (0xFF) or Off (0x00) to its associated group. |
3 | 5 | basic set commandWhen the output of the ZW47 Enpoint2 socket is changed, On (0xFF) or Off (0x00)orOverload, The ZW47 will automatically send out a relatedbasic set command. On (0xFF) or Off (0x00) to its associated group. |
Restores state after power failure Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | The state before a power outage. |
1 | outlet on |
2 | outlet off |
Endpoint1 Enable Auto Turn-ON Timer Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | EP1 Auto Turn-ON Timer Disabled |
1 | EP1 Auto Turn-ON Timer Enabled |
Endpoint1 Count Down Configuration(Turn on the output by time Size: 4 Byte, Default Value: 60
Setting | Description |
---|---|
1 - 65535 | Endpoint1 Count Down Configuration(Turn on the output by time |
Endpoint2 Enable Auto Turn-OFF Timer Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | EP2 Auto Turn-OFF Timer Disabled |
1 | EP2 Auto Turn-OFF Timer Enabled |
Endpoint2 Count Down Configuration(Turn off the output by time Size: 4 Byte, Default Value: 60
Setting | Description |
---|---|
1 - 65535 | Endpoint2 Count Down Configuration(Turn off the output by time |
`Endpoint2 Enable Auto Turn-ON Timer Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | EP2 Auto Turn-ON Timer Disabled |
1 | EP2 Auto Turn-ON Timer Enabled |
Endpoint2 Count Down Configuration(Turn on the output by time Size: 4 Byte, Default Value: 60
Setting | Description |
---|---|
1 - 65535 | Endpoint2 Count Down Configuration(Turn on the output by time |
Manual Control Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Manual Control Disabled |
1 | Manual Control Enabled |
Status LED Configuration Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | LED indicator will display power consumption whenever the device is plugged in |
1 | LED indicator will display power consumption whenever the device is ON in and will turn off when the plug is OFF |
2 | LED indicator will display the level of power consumption for 5 seconds only whenever the device is turned on or off |
3 | Always OFF |
Power Wattage Report Value Threshold(Wattage) Size: 4 Byte, Default Value: 10
Setting | Description |
---|---|
0 - 10 | Power Wattage Report Value Threshold(Wattage) |
Energy (kWh) Report Frequency (Timer) Size: 4 Byte, Default Value: 300
Setting | Description |
---|---|
30 - 2678400 | Energy (kWh) Report Frequency (Timer) |
Voltage (V) Report Frequency (Timer) Size: 4 Byte, Default Value: 300
Setting | Description |
---|---|
30 - 2678400 | Voltage (V) Report Frequency (Timer) |
Electricity (A) Report Frequency (Timer) Size: 4 Byte, Default Value: 300
Setting | Description |
---|---|
0 - 30 | Power Wattage Report Value Threshold(Wattage) |
30 - 2678400 | Electricity (A) Report Frequency (Timer) |
Overload Protection (Current) Size: 1 Byte, Default Value: 13
Setting | Description |
---|---|
1 - 16 | Overload Protection (Current) |
Endpoint1 Enable Auto Turn-OFF Timer Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | EP1 Auto Turn-OFF Timer Disabled |
1 | EP1Auto Turn-OFF Timer Enabled |
Endpoint1 Count Down Configuration(Turn off the output by time Size: 4 Byte, Default Value: 60
Setting | Description |
---|---|
1 - 65535 | Endpoint1 Count Down Configuration(Turn off the output by time |
Hardware Platform | ZM5202 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 255 FW: 1.00 |
Z-Wave Version | 6.71.03 |
Certification ID | ZC10-18116324 |
Z-Wave Product Id | 0x0312.0xA000.0xA003 |
Electric Load Type | FluorescentIncandescentInductive (e.g. Motor)LED |
Color | White |
Supported Meter Type | Electric Energy |
Firmware Updatable | Updatable by Consumer by RF |
Supported Notification Types | Power Management |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |