This is a
1. Initiate inclusion (pairing) in the app (or web interface) of your hub.2. Tap the upper paddle on the switch 3 times quickly.
FEATURES:- Manual or Z-Wave on/off control with instant status updates- Simple Direct 3-Way: connect with existing on/off switches in 3-way, 4-way, and 5-way set-ups, no add-on needed (neutral wire required)- Remembers and restores on/off status after power failure- LED indicator signals inclusion, exclusion, reset, and setting changes- Built-in Z-Wave Plus signal repeater to extend network range- Works with LED, CFL, and incandescent bulbs- S2 security protocol and the latest 500 Z-Wave chip for faster and safer wireless communication- Supported by most Z-Wave controllersSPECIFICATIONS:- Model Number: ZEN26- Z-Wave Signal Frequency: 908.42 MHz- Power: 120 VAC, 60 Hz- Maximum Load: 8 A, 150 W LED/CFL, 600 W incandescent, 1200 W resistive- Range: Up to 100 feet line of sight- Operating Temperature: 32-104 F (0-40 C)- Installation and Use: Indoor only
Reset to factory default | If your primary controller is missing or inoperable, you may need to reset the device to factory settings. To complete the reset process manually, tap-tap-tapnhold the upper paddle for at least 10 seconds. The LED indicator will flash to confirm successful reset.NOTE: All previously recorded activity and custom settings will be erased from the devices memory. |
Inclusion | 1. Initiate inclusion (pairing) in the app (or web interface) of your hub.2. Tap the upper paddle on the switch 3 times quickly. |
Exclusion | 1. Bring your Z-Wave gateway (hub) close to the switch if possible2. Put the Z-Wave hub into exclusion mode (not sure how to do that?ask@getzooz.com)3. Tap the lower paddle on the switch 3 times quickly |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Z-Wave Plus Lifeline |
2 | 5 | This device will send BINARY SWITCH REPORT to Group 1 and 2 when operated manually. |
Choose if you want the upper paddle to turn the light on or turn the light off when tapped. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Upper paddle turns the light on, lower paddle turns the light off |
1 | Upper paddle turns the light off, lower paddle turns the light on |
Choose if you want the LED indicator to turn on when the switch (light) is on or off, or if you want it to remain on or off at all times. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | LED indicator is on when switch is off, LED indicator is off when switch is on |
1 | LED indicator is on when switch is on, LED indicator is off when switch is off |
2 | LED indicator is always OFF |
3 | LED indicator is always ON |
Use this parameter to set the time after which you want the switch to automatically turn off once it has been turned on. The number entered as value corresponds to the number of seconds. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | timer disabled |
1 - 32768 | seconds |
Set the on off status for the switch after power failure. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | forced to OFF (regardless of state prior to power outage) |
1 | forced to ON (regardless of state prior to power outage) |
2 | remembers and restores on/off status after power failure |
Hardware Platform | ZM5202 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.00 |
Z-Wave Version | 6.71.03 |
Certification ID | ZC10-18116308 |
Z-Wave Product Id | 0x027A.0xA000.0xA001 |
Color | White |
Electric Load Type | IncandescentLED |
Neutral Wire Required | ok |
Firmware Updatable | Updatable by Consumer by RF |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |