Quickstart

This is a secure On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
1. Initiate inclusion (pairing) in the app (or web interface) of your hub.2. Tap the upper paddle on the switch 3 times quickly.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

FEATURES:- Manual or Z-Wave on/off control with instant status updates- Simple Direct 3-Way: connect with existing on/off switches in 3-way, 4-way, and 5-way set-ups, no add-on needed (neutral wire required)- Remembers and restores on/off status after power failure- LED indicator signals inclusion, exclusion, reset, and setting changes- Built-in Z-Wave Plus signal repeater to extend network range- Works with LED, CFL, and incandescent bulbs- S2 security protocol and the latest 500 Z-Wave chip for faster and safer wireless communication- Supported by most Z-Wave controllersSPECIFICATIONS:- Model Number: ZEN26- Z-Wave Signal Frequency: 908.42 MHz- Power: 120 VAC, 60 Hz- Maximum Load: 8 A, 150 W LED/CFL, 600 W incandescent, 1200 W resistive- Range: Up to 100 feet line of sight- Operating Temperature: 32-104 F (0-40 C)- Installation and Use: Indoor only

Reset to factory default If your primary controller is missing or inoperable, you may need to reset the device to factory settings. To complete the reset process manually, tap-tap-tapnhold the upper paddle for at least 10 seconds. The LED indicator will flash to confirm successful reset.NOTE: All previously recorded activity and custom settings will be erased from the devices memory.
Inclusion 1. Initiate inclusion (pairing) in the app (or web interface) of your hub.2. Tap the upper paddle on the switch 3 times quickly.
Exclusion 1. Bring your Z-Wave gateway (hub) close to the switch if possible2. Put the Z-Wave hub into exclusion mode (not sure how to do that?ask@getzooz.com)3. Tap the lower paddle on the switch 3 times quickly
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Z-Wave Plus Lifeline
2 5 This device will send BINARY SWITCH REPORT to Group 1 and 2 when operated manually.

Configuration Parameters

Parameter 1: Paddle Control

Choose if you want the upper paddle to turn the light on or turn the light off when tapped.
Size: 1 Byte, Default Value: 0

Setting Description
0 Upper paddle turns the light on, lower paddle turns the light off
1 Upper paddle turns the light off, lower paddle turns the light on

Parameter 2: LED Indicator Control

Choose if you want the LED indicator to turn on when the switch (light) is on or off, or if you want it to remain on or off at all times.
Size: 1 Byte, Default Value: 0

Setting Description
0 LED indicator is on when switch is off, LED indicator is off when switch is on
1 LED indicator is on when switch is on, LED indicator is off when switch is off
2 LED indicator is always OFF
3 LED indicator is always ON

Parameter 3: Auto Turn-Off Timer

Use this parameter to set the time after which you want the switch to automatically turn off once it has been turned on. The number entered as value corresponds to the number of seconds.
Size: 2 Byte, Default Value: 0

Setting Description
0 timer disabled
1 - 32768 seconds

Parameter 5: On Off Status After Power Failure

Set the on off status for the switch after power failure.
Size: 1 Byte, Default Value: 2

Setting Description
0 forced to OFF (regardless of state prior to power outage)
1 forced to ON (regardless of state prior to power outage)
2 remembers and restores on/off status after power failure

Technical Data

Hardware Platform ZM5202
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.00
Z-Wave Version 6.71.03
Certification ID ZC10-18116308
Z-Wave Product Id 0x027A.0xA000.0xA001
Color White
Electric Load Type IncandescentLED
Neutral Wire Required ok
Firmware Updatable Updatable by Consumer by RF
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoOn/Off Power Switch