This is a
A.) Plug the Wireless-Socket into an outlet. The Status-LED is flashing.B.) Click the + (Add) button in your Z-Wave App and follow the further instructionsC.) Press the Network-Button on the Socket once. The App will show if the Add device process was successful. The Status LED does not flash anymore but indicates if device is switched on or off. Repeat the inclusion process from step B if it was not successful.
the ABUS Z-Wave Wireless Socket is a compact plug adapter for switching connected devices and power metering. It includes a repeater function for extending the range of the Z-Wave radio signal. The Socket can be triggered remotely via the contected Gateway or by a button on the device.
Reset to factory default | 1. Keep pressing the Button on the socket for more than 5 seconds (the flash interval of the Status LED is now accelerated)2. The wireless socket is now restored to factory settingsNote: 1, This procedure should only be used if the primary gateway is not capable of acting. 2, If the multi-sensor is set to the factory setting, the status is set to "not included", the association settings and possible configurations are reset to default. |
Inclusion | A.) Plug the Wireless-Socket into an outlet. The Status-LED is flashing.B.) Click the + (Add) button in your Z-Wave App and follow the further instructionsC.) Press the Network-Button on the Socket once. The App will show if the Add device process was successful. The Status LED does not flash anymore but indicates if device is switched on or off. Repeat the inclusion process from step B if it was not successful. |
Exclusion | A.) Click the - (Remove) button in your Z-Wave App and follow the further instructions.B.) Press the Button on the socket 3 times. The App will show if the Remove Device process was successful. The Status-LED will now flash continuously. Repeat the exclusion process from step A if it was not successful. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline1. When the state of Smart Plug (turn on or off the load) is changed: 1.Set Configuration parameter 0x03 to 0:Do not send Basic Report 2. Set Configuration parameter 0x03 to 1: Send Basic Report 3. Set Configuration parameter 0x03 to 2: Send Basic Report only when Load condition is changed not by Z-WAVE Command, such as short pressing. 2. Sending Meter Report. |
Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | function is disabled |
1 - 0 | function is enabled (default) |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
85 - 0 | Setting the parameters 101~104 to the default value. |
0 | function is disabled |
Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
5 - 2678400 | Available Settings (default) |
0 | function is disabled |
Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
5 - 2678400 | Available Settings (default) |
0 | function is disabled |
Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
5 - 2678400 | Available Settings (default) |
0 | function is disabled |
Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
5 - 2678400 | Available Settings (default) |
0 | function is disabled |
Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
1 - 65535 | Available settings (default) |
0 | function is disabled |
Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
-128 - 127 | Available settings (default) |
0 | function is disabled |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Smart Plug memorizes its state after a power failure. (default) |
1 - 0 | Connected device will be on after the power supply is reconnected. |
2 - 0 | Connected device will be off after the power supply is reconnected. |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | unlock (default) |
1 - 0 | lock |
Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | function is disabled |
1 - 0 | send basic report (default) |
2 - 0 | Send Basic report only when Load status is not changed by Z-Wave command |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | The LED status follows the load change (default) |
1 - 0 | when operating the load, the LED lights for 5 seconds and then turns off. |
Hardware Platform | ZM5101 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 2.12 |
Z-Wave Version | 6.71.01 |
Certification ID | ZC10-18116297 |
Z-Wave Product Id | 0x0403.0x0003.0x0003 |
Supported Meter Type | Electric Energy |
Firmware Updatable | Updatable by Consumer by RF |
Switch Type | Push Button |
Z-Wave Scene Type | Scene |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |