Quickstart

This is a secure On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
A.) Plug the Wireless-Socket into an outlet. The Status-LED is flashing.B.) Click the + (Add) button in your Z-Wave App and follow the further instructionsC.) Press the Network-Button on the Socket once. The App will show if the Add device process was successful. The Status LED does not flash anymore but indicates if device is switched on or off. Repeat the inclusion process from step B if it was not successful.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

the ABUS Z-Wave Wireless Socket is a compact plug adapter for switching connected devices and power metering. It includes a repeater function for extending the range of the Z-Wave radio signal. The Socket can be triggered remotely via the contected Gateway or by a button on the device.

Reset to factory default 1. Keep pressing the Button on the socket for more than 5 seconds (the flash interval of the Status LED is now accelerated)2. The wireless socket is now restored to factory settingsNote: 1, This procedure should only be used if the primary gateway is not capable of acting. 2, If the multi-sensor is set to the factory setting, the status is set to "not included", the association settings and possible configurations are reset to default.
Inclusion A.) Plug the Wireless-Socket into an outlet. The Status-LED is flashing.B.) Click the + (Add) button in your Z-Wave App and follow the further instructionsC.) Press the Network-Button on the Socket once. The App will show if the Add device process was successful. The Status LED does not flash anymore but indicates if device is switched on or off. Repeat the inclusion process from step B if it was not successful.
Exclusion A.) Click the - (Remove) button in your Z-Wave App and follow the further instructions.B.) Press the Button on the socket 3 times. The App will show if the Remove Device process was successful. The Status-LED will now flash continuously. Repeat the exclusion process from step A if it was not successful.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plus Lifeline1. When the state of Smart Plug (turn on or off the load) is changed: 1.Set Configuration parameter 0x03 to 0:Do not send Basic Report 2. Set Configuration parameter 0x03 to 1: Send Basic Report 3. Set Configuration parameter 0x03 to 2: Send Basic Report only when Load condition is changed not by Z-WAVE Command, such as short pressing. 2. Sending Meter Report.

Configuration Parameters

Parameter 1: Over current protection


Size: 1 Byte, Default Value: 1

Setting Description
0 function is disabled
1 - 0 function is enabled (default)

Parameter 100: Setting the parameters 101~104 to the default value.


Size: 1 Byte, Default Value: 0

Setting Description
85 - 0 Setting the parameters 101~104 to the default value.
0 function is disabled

Parameter 101: setting time for sending meter report (watt)


Size: 4 Byte, Default Value: 0

Setting Description
5 - 2678400 Available Settings (default)
0 function is disabled

Parameter 102: setting time for sending meter report (KWh)


Size: 4 Byte, Default Value: 0

Setting Description
5 - 2678400 Available Settings (default)
0 function is disabled

Parameter 103: setting time for sending meter report (voltage)


Size: 4 Byte, Default Value: 0

Setting Description
5 - 2678400 Available Settings (default)
0 function is disabled

Parameter 104: setting time for sending meter report (current)


Size: 4 Byte, Default Value: 0

Setting Description
5 - 2678400 Available Settings (default)
0 function is disabled

Parameter 16: The value represents min. change in wattage (in terms of wattage) for a meter report to be sent


Size: 2 Byte, Default Value: 0

Setting Description
1 - 65535 Available settings (default)
0 function is disabled

Parameter 17: The value here represents minimum change in wattage percent (in terms of percentage) for a meter report (watt) to be sent


Size: 2 Byte, Default Value: 0

Setting Description
-128 - 127 Available settings (default)
0 function is disabled

Parameter 2: Setting device status after power failure


Size: 1 Byte, Default Value: 0

Setting Description
0 Smart Plug memorizes its state after a power failure. (default)
1 - 0 Connected device will be on after the power supply is reconnected.
2 - 0 Connected device will be off after the power supply is reconnected.

Parameter 254: Enable/disable the configuration command


Size: 1 Byte, Default Value: 0

Setting Description
0 unlock (default)
1 - 0 lock

Parameter 3: Notification when Load status changes


Size: 1 Byte, Default Value: 1

Setting Description
0 function is disabled
1 - 0 send basic report (default)
2 - 0 Send Basic report only when Load status is not changed by Z-Wave command

Parameter 4: LED Load indicator mode selection


Size: 1 Byte, Default Value: 0

Setting Description
0 The LED status follows the load change (default)
1 - 0 when operating the load, the LED lights for 5 seconds and then turns off.

Technical Data

Hardware Platform ZM5101
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 2.12
Z-Wave Version 6.71.01
Certification ID ZC10-18116297
Z-Wave Product Id 0x0403.0x0003.0x0003
Supported Meter Type Electric Energy
Firmware Updatable Updatable by Consumer by RF
Switch Type Push Button
Z-Wave Scene Type Scene
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)On/Off Power Switch