This is a
1. Put the Z-Wave Controller into inclusion mode.2. Press the link key three times within 1.5 seconds to put the unit into inclusion mode.
The AN188 is a miniature size on/off and metering plug to control lighting and appliances. It is possible to turn on/off home devices and check the status directly from a smartphone.Compact in design, yet certified for safety by makes it suitable for plugging into any power outlet. The metering plug can support wattage, voltage, ampere, and measurement. The unit can also detect overload upon which the unit will switch off relay and keep LED flashing until power is off and re-applied.
Reset to factory default | 1. Press the link key three times within 1.5 seconds to put the unit into exclusion mode.2. Within 1 second of step 1, press link key again and hold it until LED is off (about 5 seconds).3. Node ID is excluded.The device reverts to factory default state and will be in auto-inclusion mode for 25 secs.(Use this procedure only in the event that the network primary controller is missing, or otherwise inoperable.) |
Inclusion | 1. Put the Z-Wave Controller into inclusion mode.2. Press the link key three times within 1.5 seconds to put the unit into inclusion mode. |
Exclusion | 1. Put the Z-Wave Controller into exclusion mode.2. Press the link key three times within 1.5 seconds to put the unit into exclusion mode. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Z-Wave Plus Lifeline |
2 | 4 | On/Off Control |
Basic Set Command value can be set 0~99, 255 Size: 2 Byte, Default Value: 255
Setting | Description |
---|---|
0 - 99 | Basic Set Command value |
255 | 0xFF |
Value of the delaying time to report to Group 1 can be set 3~25 seconds Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
3 - 25 | Delaying time to report to Group 1 |
1: remember0: do not remember Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 1 | remember or not remember the last status |
Value of the interval for wattage auto report can be set 1~32767 minutes. Size: 2 Byte, Default Value: 1
Setting | Description |
---|---|
1 - 32767 | The interval for wattage auto report |
Value of the interval for kW*h auto report can be set 1~32676 minutes. Size: 2 Byte, Default Value: 60
Setting | Description |
---|---|
1 - 32676 | The interval for kW*h auto report |
Value can be set 0~3500W Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 3500 | 0: does not report automatically |
Value can be set 0~100% Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 100 | 0: does not report automatically |
Hardware Platform | SD3502 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.00:00.04 |
Z-Wave Version | 6.71.03 |
Certification ID | ZC10-18106289 |
Z-Wave Product Id | 0x0060.0x0004.0x000D |
Firmware Updatable | Updatable by Consumer via Internet |
Color | White |
Supported Notification Types | Power Management |
Supported Meter Type | Electric Energy |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |