Quickstart

This is a secure On/Off Power Switch for CEPT (Europe). To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
1. Put the Z-Wave Controller into inclusion mode.2. Press the link key three times within 1.5 seconds to put the unit into inclusion mode.

Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.


Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.

This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.

If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.

Product Description

The AN188 is a miniature size on/off and metering plug to control lighting and appliances. It is possible to turn on/off home devices and check the status directly from a smartphone.Compact in design, yet certified for safety by makes it suitable for plugging into any power outlet. The metering plug can support wattage, voltage, ampere, and measurement. The unit can also detect overload upon which the unit will switch off relay and keep LED flashing until power is off and re-applied.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.

Reset to factory default

This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.

1. Press the link key three times within 1.5 seconds to put the unit into exclusion mode.2. Within 1 second of step 1, press link key again and hold it until LED is off (about 5 seconds).3. Node ID is excluded.The device reverts to factory default state and will be in auto-inclusion mode for 25 secs.(Use this procedure only in the event that the network primary controller is missing, or otherwise inoperable.)

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.

Inclusion

1. Put the Z-Wave Controller into inclusion mode.2. Press the link key three times within 1.5 seconds to put the unit into inclusion mode.

Exclusion

1. Put the Z-Wave Controller into exclusion mode.2. Press the link key three times within 1.5 seconds to put the unit into exclusion mode.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association - one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.

Association Groups:

Group Number Maximum Nodes Description
1 1 Z-Wave Plus Lifeline
2 4 On/Off Control

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.

IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.

Parameter 1: Set Basic Set Command value

Basic Set Command value can be set 0~99, 255
Size: 2 Byte, Default Value: 255

Setting Description
0 - 99 Basic Set Command value
255 0xFF

Parameter 2: Set the delaying time to report to Group 1

Value of the delaying time to report to Group 1 can be set 3~25 seconds
Size: 1 Byte, Default Value: 3

Setting Description
3 - 25 Delaying time to report to Group 1

Parameter 3: Set whether to remember the last status

1: remember0: do not remember
Size: 1 Byte, Default Value: 1

Setting Description
0 - 1 remember or not remember the last status

Parameter 4: Set the interval for wattage auto report

Value of the interval for wattage auto report can be set 1~32767 minutes.
Size: 2 Byte, Default Value: 1

Setting Description
1 - 32767 The interval for wattage auto report

Parameter 5: Set the interval for kW*h auto report

Value of the interval for kW*h auto report can be set 1~32676 minutes.
Size: 2 Byte, Default Value: 60

Setting Description
1 - 32676 The interval for kW*h auto report

Parameter 6: Auto report when load surpasses the set value of wattage

Value can be set 0~3500W
Size: 2 Byte, Default Value: 0

Setting Description
0 - 3500 0: does not report automatically

Parameter 7: Auto report when the change of wattage surpasses the set percentage

Value can be set 0~100%
Size: 1 Byte, Default Value: 0

Setting Description
0 - 100 0: does not report automatically

Technical Data

Hardware Platform SD3502
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.00:00.04
Z-Wave Version 6.71.03
Certification ID ZC10-18106289
Z-Wave Product Id 0x0060.0x0004.0x000D
Firmware Updatable Updatable by Consumer via Internet
Color White
Supported Notification Types Power Management
Supported Meter Type Electric Energy
Security V2 S2_UNAUTHENTICATED ,S2_AUTHENTICATED
Frequency XXfrequency
Maximum transmission power XXantenna

Supported Command Classes

  • Application Status
  • Association Grp Info
  • Association V2
  • Basic
  • Configuration
  • Device Reset Locally
  • Firmware Update Md V4
  • Manufacturer Specific V2
  • Meter V3
  • Notification V4
  • Powerlevel
  • Security
  • Security 2
  • Supervision
  • Switch Binary
  • Transport Service V2
  • Version V2
  • Zwaveplus Info V2

Controlled Command Classes

  • Basic

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network. Controllers are typically Gateways,Remote Controls or battery operated wall controllers.
  • Slave — is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators and even remote controls.
  • Primary Controller — is the central organizer of the network. It must be a controller. There can be only one primary controller in a Z-Wave network.
  • Inclusion — is the process of adding new Z-Wave devices into a network.
  • Exclusion — is the process of removing Z-Wave devices from the network.
  • Association — is a control relationship between a controlling device and a controlled device.
  • Wakeup Notification — is a special wireless message issued by a Z-Wave device to announces that is able to communicate.
  • Node Information Frame — is a special wireless message issued by a Z-Wave device to announce its capabilities and functions.